{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/46442"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/46442","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Modeling thermal environment of a recirculating aquaculture system facility","abstract":"Economic viability of fish production in recirculating aquaculture system (RAS) facility depends on minimizing the energy requirements of operating such facilities. The fish growth and water quality aspects of RAS have been studied in considerable details. However, the understanding of the thermal environment of RAS lags behind. A step-wise steady-state thermal model was developed to simulate the daily heating, ventilation, water pumping, biofilter operation, and lighting energy requirements over a production cycle. The model was validated using temperature and energy data collected from RAS facility of Virginia Tech during 1992. Model simulations were performed with various production scenarios. The energy cost of fish production ($/kg) was used to evaluate different scenarios with and without heat recovery from discharged system water. Building heating required the most (40 % - 70 % of total) energy followed by water pumping, biofilter operation, lighting, and ventilation. Water replacement was the most dominant factor in determining the facility’s heating energy requirement. Heat recovery from discharged system water indicated significant drop (up to 40 %) in energy cost of fish production.","abstract_html":"Economic viability of fish production in recirculating aquaculture system (RAS) facility depends on minimizing the energy requirements of operating such facilities. The fish growth and water quality aspects of RAS have been studied in considerable details. However, the understanding of the thermal environment of RAS lags behind. A step-wise steady-state thermal model was developed to simulate the daily heating, ventilation, water pumping, biofilter operation, and lighting energy requirements over a production cycle. The model was validated using temperature and energy data collected from RAS facility of Virginia Tech during 1992. Model simulations were performed with various production scenarios. The energy cost of fish production ($/kg) was used to evaluate different scenarios with and without heat recovery from discharged system water. Building heating required the most (40 % - 70 % of total) energy followed by water pumping, biofilter operation, lighting, and ventilation. Water replacement was the most dominant factor in determining the facility’s heating energy requirement. Heat recovery from discharged system water indicated significant drop (up to 40 %) in energy cost of fish production.","abstract_has_math":false,"creators":["Singh, Sahdev"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Agricultural Engineering","degree_department":"Agricultural Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993","date_published":"1993","updated_at":"2026-11-18T20:16:10Z","subjects":["Aquacultural engineering -- Models","Fish hatcheries","Heat -- Transmission -- Models"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12302008-063343"],"render_values":[{"text":"etd-12302008-063343","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-12302008-063343/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-12302008-063343/","href":"http://scholar.lib.vt.edu/theses/available/etd-12302008-063343/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/46442","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/46442","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F46442","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Agricultural Engineering"]},{"key":"dc:creator","label":"Author","values":["Singh, Sahdev"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2008-12-30"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:52:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:52:41Z","2008-12-30"]},{"key":"dc:date.issued","label":"Date","values":["1993"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2008-12-30"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1993.S564.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 28552960"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Agricultural Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1993.S564"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Aquacultural engineering -- Models","Fish hatcheries","Heat -- Transmission -- Models"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12302008-063343"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-12302008-063343/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/46442"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Economic viability of fish production in recirculating aquaculture system (RAS) facility depends on minimizing the energy requirements of operating such facilities. The fish growth and water quality aspects of RAS have been studied in considerable details. However, the understanding of the thermal environment of RAS lags behind. A step-wise steady-state thermal model was developed to simulate the daily heating, ventilation, water pumping, biofilter operation, and lighting energy requirements over a production cycle. The model was validated using temperature and energy data collected from RAS facility of Virginia Tech during 1992. Model simulations were performed with various production scenarios. The energy cost of fish production ($/kg) was used to evaluate different scenarios with and without heat recovery from discharged system water. Building heating required the most (40 % - 70 % of total) energy followed by water pumping, biofilter operation, lighting, and ventilation. Water replacement was the most dominant factor in determining the facility’s heating energy requirement. Heat recovery from discharged system water indicated significant drop (up to 40 %) in energy cost of fish production."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xi, 146 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Modeling thermal environment of a recirculating aquaculture system facility"]}]}],"canonical_facts":{"dc:contributor.department":["Agricultural Engineering"],"dc:creator":["Singh, Sahdev"],"dc:date.accepted":["2008-12-30"],"dc:date.accessioned":["2014-03-14T21:52:41Z"],"dc:date.available":["2014-03-14T21:52:41Z","2008-12-30"],"dc:date.issued":["1993"],"dc:date.submitted":["2008-12-30"],"dc:description.abstract":["Economic viability of fish production in recirculating aquaculture system (RAS) facility depends on minimizing the energy requirements of operating such facilities. The fish growth and water quality aspects of RAS have been studied in considerable details. However, the understanding of the thermal environment of RAS lags behind. A step-wise steady-state thermal model was developed to simulate the daily heating, ventilation, water pumping, biofilter operation, and lighting energy requirements over a production cycle. The model was validated using temperature and energy data collected from RAS facility of Virginia Tech during 1992. Model simulations were performed with various production scenarios. The energy cost of fish production ($/kg) was used to evaluate different scenarios with and without heat recovery from discharged system water. Building heating required the most (40 % - 70 % of total) energy followed by water pumping, biofilter operation, lighting, and ventilation. Water replacement was the most dominant factor in determining the facility’s heating energy requirement. Heat recovery from discharged system water indicated significant drop (up to 40 %) in energy cost of fish production."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xi, 146 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-12302008-063343"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-12302008-063343/"],"dc:identifier.uri":["http://hdl.handle.net/10919/46442"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1993.S564.pdf"],"dc:relation.isformatof":["OCLC# 28552960"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1993.S564"],"dc:subject.lcsh":["Aquacultural engineering -- Models","Fish hatcheries","Heat -- Transmission -- Models"],"dc:title":["Modeling thermal environment of a recirculating aquaculture system facility"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Agricultural Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:16:10Z"}