{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/50081"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/50081","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Design of a patient monitoring system for cardiopulmonary bypass surgery","abstract":"A patient monitoring system for cardiopulmonary bypass surgery has been developed. This monitoring system uses a SWAN 286-10 computer (fully IBM PC/AT compatible) and a DT280l-A Input/Output board to monitor seven surgical parameters. This system monitors six temperatures, the hemoglobin content, the arterial oxygen saturation, the venous oxygen saturation, the oxygen consumption, and the blood flow rate through the cardiopulmonary bypass circuit. Additionally, there are three individual timers available. Details and the evaluation of the hardware and software design of this monitoring system are presented. Also, recommendations for clinical use are discussed.","abstract_html":"A patient monitoring system for cardiopulmonary bypass surgery has been developed. This monitoring system uses a SWAN 286-10 computer (fully IBM PC/AT compatible) and a DT280l-A Input/Output board to monitor seven surgical parameters. This system monitors six temperatures, the hemoglobin content, the arterial oxygen saturation, the venous oxygen saturation, the oxygen consumption, and the blood flow rate through the cardiopulmonary bypass circuit. Additionally, there are three individual timers available. Details and the evaluation of the hardware and software design of this monitoring system are presented. Also, recommendations for clinical use are discussed.","abstract_has_math":false,"creators":["Rice, Cynthia K."],"institution":"Virginia Polytechnic Institute and State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Arp, Leon J."],"committee_members":["Furey, M. J.","Larsen, D. G."],"year":1989,"date_issued":"1989","date_published":"1989","updated_at":"2026-11-18T20:14:29Z","subjects":["Coronary care units","Coronary artery bypass","Hospital patients -- Services for"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/50081","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/50081","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F50081","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Arp, Leon J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Furey, M. J.","Larsen, D. G."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Rice, Cynthia K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-08-13T14:40:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-08-13T14:40:19Z"]},{"key":"dc:date.issued","label":"Date","values":["1989"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 20442420"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1989.R523"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Coronary care units","Coronary artery bypass","Hospital patients -- Services for"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/50081"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A patient monitoring system for cardiopulmonary bypass surgery has been developed. This monitoring system uses a SWAN 286-10 computer (fully IBM PC/AT compatible) and a DT280l-A Input/Output board to monitor seven surgical parameters. This system monitors six temperatures, the hemoglobin content, the arterial oxygen saturation, the venous oxygen saturation, the oxygen consumption, and the blood flow rate through the cardiopulmonary bypass circuit. Additionally, there are three individual timers available. Details and the evaluation of the hardware and software design of this monitoring system are presented. Also, recommendations for clinical use are discussed."]},{"key":"dc:description.admin","label":"Dc Description Admin","values":["incomplete_metadata"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["viii, 275 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design of a patient monitoring system for cardiopulmonary bypass surgery"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Arp, Leon J."],"dc:contributor.committeemember":["Furey, M. J.","Larsen, D. G."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Rice, Cynthia K."],"dc:date.accessioned":["2014-08-13T14:40:19Z"],"dc:date.available":["2014-08-13T14:40:19Z"],"dc:date.issued":["1989"],"dc:description.abstract":["A patient monitoring system for cardiopulmonary bypass surgery has been developed. This monitoring system uses a SWAN 286-10 computer (fully IBM PC/AT compatible) and a DT280l-A Input/Output board to monitor seven surgical parameters. This system monitors six temperatures, the hemoglobin content, the arterial oxygen saturation, the venous oxygen saturation, the oxygen consumption, and the blood flow rate through the cardiopulmonary bypass circuit. Additionally, there are three individual timers available. Details and the evaluation of the hardware and software design of this monitoring system are presented. Also, recommendations for clinical use are discussed."],"dc:description.admin":["incomplete_metadata"],"dc:description.degree":["Master of Science"],"dc:format.extent":["viii, 275 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/50081"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:relation.isformatof":["OCLC# 20442420"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1989.R523"],"dc:subject.lcsh":["Coronary care units","Coronary artery bypass","Hospital patients -- Services for"],"dc:title":["Design of a patient monitoring system for cardiopulmonary bypass surgery"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:14:29Z"}