{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/53199"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/53199","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Isometric forces transmitted by the digits: data collection using a standardized protocol","abstract":"Data collection on isometric forces exerted by means of the digits, is a virtually untapped research area. However, such data would prove particularly useful in areas such as hand-tool and control design, and also in medical evaluation. A standardized protocol is necessary if a sound, useful data base is to be built. This study developed such a protocol and data were collected using the defined protocol. The study also showed that occupational level (defined by tools and controls used) and gender both had significant effects on certain strength exertions of the digits. Therefore the appropriate data must be collected, depending on the intended use and user population. Regression equations were produced which predicted the strength exertions using anthropometric measurements which are commonly available. Although some particular exertions were not well predicted, the potential of prediction was verified.","abstract_html":"Data collection on isometric forces exerted by means of the digits, is a virtually untapped research area. However, such data would prove particularly useful in areas such as hand-tool and control design, and also in medical evaluation. A standardized protocol is necessary if a sound, useful data base is to be built. This study developed such a protocol and data were collected using the defined protocol. The study also showed that occupational level (defined by tools and controls used) and gender both had significant effects on certain strength exertions of the digits. Therefore the appropriate data must be collected, depending on the intended use and user population. Regression equations were produced which predicted the strength exertions using anthropometric measurements which are commonly available. Although some particular exertions were not well predicted, the potential of prediction was verified.","abstract_has_math":false,"creators":["Williams, Vicki Higginbotham"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Industrial Engineering and Operations Research","degree_department":"Industrial Engineering and Operations Research","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1988,"date_issued":"1988","date_published":"1988","updated_at":"2026-11-18T20:03:35Z","subjects":["Human engineering","Human-machine systems","Fingers"],"languages":["en_US"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/53199","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/53199","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F53199","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Industrial Engineering and Operations Research"]},{"key":"dc:creator","label":"Author","values":["Williams, Vicki Higginbotham"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-06-23T19:09:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-06-23T19:09:31Z"]},{"key":"dc:date.issued","label":"Date","values":["1988"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 19289532"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial Engineering and Operations Research"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1988.W548"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Human engineering","Human-machine systems","Fingers"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/53199"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Data collection on isometric forces exerted by means of the digits, is a virtually untapped research area. However, such data would prove particularly useful in areas such as hand-tool and control design, and also in medical evaluation. A standardized protocol is necessary if a sound, useful data base is to be built. This study developed such a protocol and data were collected using the defined protocol. The study also showed that occupational level (defined by tools and controls used) and gender both had significant effects on certain strength exertions of the digits. Therefore the appropriate data must be collected, depending on the intended use and user population. Regression equations were produced which predicted the strength exertions using anthropometric measurements which are commonly available. Although some particular exertions were not well predicted, the potential of prediction was verified."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["viii, 110 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Isometric forces transmitted by the digits: data collection using a standardized protocol"]}]}],"canonical_facts":{"dc:contributor.department":["Industrial Engineering and Operations Research"],"dc:creator":["Williams, Vicki Higginbotham"],"dc:date.accessioned":["2015-06-23T19:09:31Z"],"dc:date.available":["2015-06-23T19:09:31Z"],"dc:date.issued":["1988"],"dc:description.abstract":["Data collection on isometric forces exerted by means of the digits, is a virtually untapped research area. However, such data would prove particularly useful in areas such as hand-tool and control design, and also in medical evaluation. A standardized protocol is necessary if a sound, useful data base is to be built. This study developed such a protocol and data were collected using the defined protocol. The study also showed that occupational level (defined by tools and controls used) and gender both had significant effects on certain strength exertions of the digits. Therefore the appropriate data must be collected, depending on the intended use and user population. Regression equations were produced which predicted the strength exertions using anthropometric measurements which are commonly available. Although some particular exertions were not well predicted, the potential of prediction was verified."],"dc:description.degree":["Master of Science"],"dc:format.extent":["viii, 110 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/53199"],"dc:language.iso":["en_US"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:relation.isformatof":["OCLC# 19289532"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1988.W548"],"dc:subject.lcsh":["Human engineering","Human-machine systems","Fingers"],"dc:title":["Isometric forces transmitted by the digits: data collection using a standardized protocol"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Industrial Engineering and Operations Research"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:03:35Z"}