{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/80089"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/80089","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Microwave sensing of bulk electrical properties of tank track pad rubber","abstract":"A complex permittivity measurement system composed of a network analyzer and a open-ended coaxial waveguide has been used to evaluate the permittivity of rubber samples. The conductivity of rubber provides an indication of the dispersion of carbon black throughout the rubber matrix. The technique is based on the Deschamps antenna modeling theorem which relates the effective admittance of an antenna in some arbitrary medium to the effective admittance of the same antenna embedded in free space. This technique is well suited for material with loss tangents between 0.1 and 1.0. Only material within a radius on the order of the outer conductor radius of the coaxial waveguide is interrogated. Inferred permittivity measurements for rubber samples are presented. An APC-7 connector is used as the transducer which provides a means for convenient calibration because standard calibration terminations can be used. The amount of pressure from the sample applied to the waveguide affects reflection coefficient measurements, preventing consistent results.","abstract_html":"A complex permittivity measurement system composed of a network analyzer and a open-ended coaxial waveguide has been used to evaluate the permittivity of rubber samples. The conductivity of rubber provides an indication of the dispersion of carbon black throughout the rubber matrix. The technique is based on the Deschamps antenna modeling theorem which relates the effective admittance of an antenna in some arbitrary medium to the effective admittance of the same antenna embedded in free space. This technique is well suited for material with loss tangents between 0.1 and 1.0. Only material within a radius on the order of the outer conductor radius of the coaxial waveguide is interrogated. Inferred permittivity measurements for rubber samples are presented. An APC-7 connector is used as the transducer which provides a means for convenient calibration because standard calibration terminations can be used. The amount of pressure from the sample applied to the waveguide affects reflection coefficient measurements, preventing consistent results.","abstract_has_math":false,"creators":["Lee, Michael W."],"institution":"Virginia Polytechnic Institute and State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1988,"date_issued":"1988","date_published":"1988","updated_at":"2026-11-18T20:22:30Z","subjects":["Carbon-black -- Testing","Rubber -- Electric properties"],"languages":["en_US"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/80089","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/80089","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F80089","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Lee, Michael W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-11-09T20:41:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-11-09T20:41:51Z"]},{"key":"dc:date.issued","label":"Date","values":["1988"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 18759426"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1988.L446"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Carbon-black -- Testing","Rubber -- Electric properties"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/80089"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A complex permittivity measurement system composed of a network analyzer and a open-ended coaxial waveguide has been used to evaluate the permittivity of rubber samples. The conductivity of rubber provides an indication of the dispersion of carbon black throughout the rubber matrix. The technique is based on the Deschamps antenna modeling theorem which relates the effective admittance of an antenna in some arbitrary medium to the effective admittance of the same antenna embedded in free space. This technique is well suited for material with loss tangents between 0.1 and 1.0. Only material within a radius on the order of the outer conductor radius of the coaxial waveguide is interrogated. Inferred permittivity measurements for rubber samples are presented. An APC-7 connector is used as the transducer which provides a means for convenient calibration because standard calibration terminations can be used. The amount of pressure from the sample applied to the waveguide affects reflection coefficient measurements, preventing consistent results."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["viii, 96 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Microwave sensing of bulk electrical properties of tank track pad rubber"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Lee, Michael W."],"dc:date.accessioned":["2017-11-09T20:41:51Z"],"dc:date.available":["2017-11-09T20:41:51Z"],"dc:date.issued":["1988"],"dc:description.abstract":["A complex permittivity measurement system composed of a network analyzer and a open-ended coaxial waveguide has been used to evaluate the permittivity of rubber samples. The conductivity of rubber provides an indication of the dispersion of carbon black throughout the rubber matrix. The technique is based on the Deschamps antenna modeling theorem which relates the effective admittance of an antenna in some arbitrary medium to the effective admittance of the same antenna embedded in free space. This technique is well suited for material with loss tangents between 0.1 and 1.0. Only material within a radius on the order of the outer conductor radius of the coaxial waveguide is interrogated. Inferred permittivity measurements for rubber samples are presented. An APC-7 connector is used as the transducer which provides a means for convenient calibration because standard calibration terminations can be used. The amount of pressure from the sample applied to the waveguide affects reflection coefficient measurements, preventing consistent results."],"dc:description.degree":["Master of Science"],"dc:format.extent":["viii, 96 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/80089"],"dc:language.iso":["en_US"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:relation.isformatof":["OCLC# 18759426"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1988.L446"],"dc:subject.lcsh":["Carbon-black -- Testing","Rubber -- Electric properties"],"dc:title":["Microwave sensing of bulk electrical properties of tank track pad rubber"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:22:30Z"}