{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/91060"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/91060","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Effect of high-stress mixing on polyelectrolyte conditioning of sludges","abstract":"Experiments were performed on samples of alum and activated sludges to determine if these sludges, conditioned with polymers under high-stress, would achieve favorable dewatering rates. Tests were conducted using a variable high speed mixer with root mean square velocity gradient (G) values ranging from 560 - 2000 sec⁻¹ with both anionic and cationic high molecular weight polymers. Capillary suction time (CST) was used to measure relative changes in dewatering rates. Results indicated that readily dewatered sludges can be obtained when subjected to high-stress mixing conditions. The most significant parameters governing high-stress conditioning were determined to be polymer dose and total mixing energy input (Gt). It was discovered that as Gt increases, polymer dose requirements increase as well, so as to maintain an optimum dewatering rate. Also, the activated sludges tested in the study appear to be resistant to the effects of polymer overdosing.","abstract_html":"Experiments were performed on samples of alum and activated sludges to determine if these sludges, conditioned with polymers under high-stress, would achieve favorable dewatering rates. Tests were conducted using a variable high speed mixer with root mean square velocity gradient (G) values ranging from 560 - 2000 sec⁻¹ with both anionic and cationic high molecular weight polymers. Capillary suction time (CST) was used to measure relative changes in dewatering rates. Results indicated that readily dewatered sludges can be obtained when subjected to high-stress mixing conditions. The most significant parameters governing high-stress conditioning were determined to be polymer dose and total mixing energy input (Gt). It was discovered that as Gt increases, polymer dose requirements increase as well, so as to maintain an optimum dewatering rate. Also, the activated sludges tested in the study appear to be resistant to the effects of polymer overdosing.","abstract_has_math":false,"creators":["Prendiville, John F."],"institution":"Virginia Polytechnic Institute and State University","degree_name":"M.S.","degree_level":"masters","degree_discipline":"Environmental Engineering","degree_department":"Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1986,"date_issued":"1986","date_published":"1986","updated_at":"2026-11-18T20:25:27Z","subjects":["Sewage sludge -- Drying","Polyelectrolytes"],"languages":["en_US"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/91060","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/91060","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F91060","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Prendiville, John F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-07-03T18:56:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-07-03T18:56:44Z"]},{"key":"dc:date.issued","label":"Date","values":["1986"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 13488837"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1986.P736"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Sewage sludge -- Drying","Polyelectrolytes"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/91060"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Experiments were performed on samples of alum and activated sludges to determine if these sludges, conditioned with polymers under high-stress, would achieve favorable dewatering rates. Tests were conducted using a variable high speed mixer with root mean square velocity gradient (G) values ranging from 560 - 2000 sec⁻¹ with both anionic and cationic high molecular weight polymers. Capillary suction time (CST) was used to measure relative changes in dewatering rates. Results indicated that readily dewatered sludges can be obtained when subjected to high-stress mixing conditions. The most significant parameters governing high-stress conditioning were determined to be polymer dose and total mixing energy input (Gt). It was discovered that as Gt increases, polymer dose requirements increase as well, so as to maintain an optimum dewatering rate. Also, the activated sludges tested in the study appear to be resistant to the effects of polymer overdosing."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["vi, 89 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Effect of high-stress mixing on polyelectrolyte conditioning of sludges"]}]}],"canonical_facts":{"dc:contributor.department":["Environmental Engineering"],"dc:creator":["Prendiville, John F."],"dc:date.accessioned":["2019-07-03T18:56:44Z"],"dc:date.available":["2019-07-03T18:56:44Z"],"dc:date.issued":["1986"],"dc:description.abstract":["Experiments were performed on samples of alum and activated sludges to determine if these sludges, conditioned with polymers under high-stress, would achieve favorable dewatering rates. Tests were conducted using a variable high speed mixer with root mean square velocity gradient (G) values ranging from 560 - 2000 sec⁻¹ with both anionic and cationic high molecular weight polymers. Capillary suction time (CST) was used to measure relative changes in dewatering rates. Results indicated that readily dewatered sludges can be obtained when subjected to high-stress mixing conditions. The most significant parameters governing high-stress conditioning were determined to be polymer dose and total mixing energy input (Gt). It was discovered that as Gt increases, polymer dose requirements increase as well, so as to maintain an optimum dewatering rate. Also, the activated sludges tested in the study appear to be resistant to the effects of polymer overdosing."],"dc:description.degree":["M.S."],"dc:format.extent":["vi, 89 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/91060"],"dc:language.iso":["en_US"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:relation.isformatof":["OCLC# 13488837"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1986.P736"],"dc:subject.lcsh":["Sewage sludge -- Drying","Polyelectrolytes"],"dc:title":["Effect of high-stress mixing on polyelectrolyte conditioning of sludges"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Environmental Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:25:27Z"}