{"id":{"repo_id":"vu-aus","oai_identifier":"oai:eprints.vu.edu.au:31829"},"canonical_url":"https://search.ndltd.org/etd/vu-aus/oai:eprints.vu.edu.au:31829","repository":{"repo_id":"vu-aus","name":"Victoria University (Australia)","base_url":"https://vuir.vu.edu.au/cgi/oai2"},"display":{"title":"Development of Protection Scheme for Non-Conventional Instrument Transformer (NCITs) Based on IEC 61850-9-2","abstract":"Substations are a fundamental part in electrical energy transmission and distribution. The role of a substation is to transfer and transform electrical energy by stepping up or down the voltage. To do this, high voltage switching equipment and power transformers are used, in addition to instrument transformers that supply the status of the primary system to the secondary equipment. Substation Automation Systems are then used to control, protect and monitor the substations [1]. The IEC 61850 standard developed digital substation with most advanced techniques. The IEC 61850 standard define in its sub-clauses IEC 600448 and IEC 61850-9-2 about digital interface, digital communication and Sampled Values transmission over an Ethernet link called Process Bus. This thesis is mainly based on the development of the non Conventional Instrument Transformers (NCIT), analogue to digital data converter and power system protection.","abstract_html":"Substations are a fundamental part in electrical energy transmission and distribution. The role of a substation is to transfer and transform electrical energy by stepping up or down the voltage. To do this, high voltage switching equipment and power transformers are used, in addition to instrument transformers that supply the status of the primary system to the secondary equipment. Substation Automation Systems are then used to control, protect and monitor the substations [1]. The IEC 61850 standard developed digital substation with most advanced techniques. The IEC 61850 standard define in its sub-clauses IEC 600448 and IEC 61850-9-2 about digital interface, digital communication and Sampled Values transmission over an Ethernet link called Process Bus. This thesis is mainly based on the development of the non Conventional Instrument Transformers (NCIT), analogue to digital data converter and power system protection.","abstract_has_math":false,"creators":["Khan, Muhammad Salman"],"institution":"Victoria University","degree_name":"other","degree_level":"rmaster","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-25T20:43:16Z","subjects":["0906 Electrical and Electronic Engineering","College of Science and Engineering"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://vuir.vu.edu.au/31829/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://vuir.vu.edu.au/31829/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Avu-aus%3Aoai%3Aeprints.vu.edu.au%3A31829","prefix":"oai_dc"},"source_record":{"url":"https://vuir.vu.edu.au/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.vu.edu.au%3A31829","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Khan, Muhammad Salman"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering and Science"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Victoria University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["rmaster"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["other"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["0906 Electrical and Electronic Engineering","College of Science and Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://vuir.vu.edu.au/31829/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Substations are a fundamental part in electrical energy transmission and distribution. The role of a substation is to transfer and transform electrical energy by stepping up or down the voltage. To do this, high voltage switching equipment and power transformers are used, in addition to instrument transformers that supply the status of the primary system to the secondary equipment. Substation Automation Systems are then used to control, protect and monitor the substations [1]. The IEC 61850 standard developed digital substation with most advanced techniques. The IEC 61850 standard define in its sub-clauses IEC 600448 and IEC 61850-9-2 about digital interface, digital communication and Sampled Values transmission over an Ethernet link called Process Bus. This thesis is mainly based on the development of the non Conventional Instrument Transformers (NCIT), analogue to digital data converter and power system protection."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of Protection Scheme for Non-Conventional Instrument Transformer (NCITs) Based on IEC 61850-9-2"]}]}],"canonical_facts":{"dc:creator":["Khan, Muhammad Salman"],"dc:date":["2015"],"dc:date.issued":["2015"],"dc:description.abstract":["Substations are a fundamental part in electrical energy transmission and distribution. The role of a substation is to transfer and transform electrical energy by stepping up or down the voltage. To do this, high voltage switching equipment and power transformers are used, in addition to instrument transformers that supply the status of the primary system to the secondary equipment. Substation Automation Systems are then used to control, protect and monitor the substations [1]. The IEC 61850 standard developed digital substation with most advanced techniques. The IEC 61850 standard define in its sub-clauses IEC 600448 and IEC 61850-9-2 about digital interface, digital communication and Sampled Values transmission over an Ethernet link called Process Bus. This thesis is mainly based on the development of the non Conventional Instrument Transformers (NCIT), analogue to digital data converter and power system protection."],"dc:format":["text"],"dc:identifier.uri":["https://vuir.vu.edu.au/31829/"],"dc:language":["en"],"dc:publisher.department":["College of Engineering and Science"],"dc:publisher.institution":["Victoria University"],"dc:subject":["0906 Electrical and Electronic Engineering","College of Science and Engineering"],"dcterms:accessrights":["public"],"dc:title":["Development of Protection Scheme for Non-Conventional Instrument Transformer (NCITs) Based on IEC 61850-9-2"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["rmaster"],"dc:type.qualificationname":["other"]},"updated_at":"2026-11-25T20:43:16Z"}