{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/17089"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/17089","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Antithrombotic Peptide Delivery from Glow-Discharge Plasma-Coated Controlled Release Matrices","abstract":"A novel polymeric matrix system has been developed to deliver agents to block platelet adhesion or inhibit thrombin activation on implanted biomaterials. The base material of the system used was BioSpan®, a medical-grade polyether-urethane urea (PEUU) elastomer, which contained a dispersion of an active agent: either an anti-platelet-adhesion peptide (echistatin), small peptide (RGDSGY), or direct antithrombin peptide (hirudin), along with bovine serum albumin (BSA) or poly(ethylene glycol) (PEG) as an excipient and poreformer. The PEUU-peptide matrix was subsequently processed using radio-frequency glowdischarge (RFGD) plasma polymerization of acrylate monomers, either 2-hydroxyethyl methacrylate (HEMA), n-butyl methacrylate (BMA), or N-isopropyl acrylamide (NIPAAm) to create a barrier membrane. Control of plasma parameters changed the cross linking of this thin, conformal barrier, and produced different release rates of the active agents from the matrix. Biologically active echistatin and hirudin were delivered successfully, but some matrices exhibited a limited reduction in release rate due to osmotic rupturing of the matrix and coating. For RGDSGY-containing matrices, the reduction in release rate with RFGD plasma coating was greatest for matrices with PEG excipients of 10,000 and 20,000 molecular weight.","abstract_html":"A novel polymeric matrix system has been developed to deliver agents to block platelet adhesion or inhibit thrombin activation on implanted biomaterials. The base material of the system used was BioSpan®, a medical-grade polyether-urethane urea (PEUU) elastomer, which contained a dispersion of an active agent: either an anti-platelet-adhesion peptide (echistatin), small peptide (RGDSGY), or direct antithrombin peptide (hirudin), along with bovine serum albumin (BSA) or poly(ethylene glycol) (PEG) as an excipient and poreformer. The PEUU-peptide matrix was subsequently processed using radio-frequency glowdischarge (RFGD) plasma polymerization of acrylate monomers, either 2-hydroxyethyl methacrylate (HEMA), n-butyl methacrylate (BMA), or N-isopropyl acrylamide (NIPAAm) to create a barrier membrane. Control of plasma parameters changed the cross linking of this thin, conformal barrier, and produced different release rates of the active agents from the matrix. Biologically active echistatin and hirudin were delivered successfully, but some matrices exhibited a limited reduction in release rate due to osmotic rupturing of the matrix and coating. For RGDSGY-containing matrices, the reduction in release rate with RFGD plasma coating was greatest for matrices with PEG excipients of 10,000 and 20,000 molecular weight.","abstract_has_math":false,"creators":["Takeno, Marc M."],"institution":"University of Washington Graduate School","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-06-10","date_published":"2005-06-10","updated_at":"2026-11-18T20:07:44Z","subjects":["platelet thrombin BioSpan elastomer peptide bovine RFGD implanted biomaterials"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/17089","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/17089","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F17089","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Takeno, Marc M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-08-24T19:49:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-08-24T19:49:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-06-10"]},{"key":"dc:publisher","label":"Institution","values":["University of Washington Graduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["platelet thrombin BioSpan elastomer peptide bovine RFGD implanted biomaterials"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/17089"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["PhD. Dissertation"]},{"key":"dc:description.abstract","label":"Abstract","values":["A novel polymeric matrix system has been developed to deliver agents to block platelet adhesion or inhibit thrombin activation on implanted biomaterials. The base material of the system used was BioSpan®, a medical-grade polyether-urethane urea (PEUU) elastomer, which contained a dispersion of an active agent: either an anti-platelet-adhesion peptide (echistatin), small peptide (RGDSGY), or direct antithrombin peptide (hirudin), along with bovine serum albumin (BSA) or poly(ethylene glycol) (PEG) as an excipient and poreformer. The PEUU-peptide matrix was subsequently processed using radio-frequency glowdischarge (RFGD) plasma polymerization of acrylate monomers, either 2-hydroxyethyl methacrylate (HEMA), n-butyl methacrylate (BMA), or N-isopropyl acrylamide (NIPAAm) to create a barrier membrane. Control of plasma parameters changed the cross linking of this thin, conformal barrier, and produced different release rates of the active agents from the matrix. Biologically active echistatin and hirudin were delivered successfully, but some matrices exhibited a limited reduction in release rate due to osmotic rupturing of the matrix and coating. For RGDSGY-containing matrices, the reduction in release rate with RFGD plasma coating was greatest for matrices with PEG excipients of 10,000 and 20,000 molecular weight."]},{"key":"dc:title","label":"Title","values":["Antithrombotic Peptide Delivery from Glow-Discharge Plasma-Coated Controlled Release Matrices"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Takeno, Marc M."],"dc:date.accessioned":["2011-08-24T19:49:50Z"],"dc:date.available":["2011-08-24T19:49:50Z"],"dc:date.issued":["2005-06-10"],"dc:description":["PhD. Dissertation"],"dc:description.abstract":["A novel polymeric matrix system has been developed to deliver agents to block platelet adhesion or inhibit thrombin activation on implanted biomaterials. The base material of the system used was BioSpan®, a medical-grade polyether-urethane urea (PEUU) elastomer, which contained a dispersion of an active agent: either an anti-platelet-adhesion peptide (echistatin), small peptide (RGDSGY), or direct antithrombin peptide (hirudin), along with bovine serum albumin (BSA) or poly(ethylene glycol) (PEG) as an excipient and poreformer. The PEUU-peptide matrix was subsequently processed using radio-frequency glowdischarge (RFGD) plasma polymerization of acrylate monomers, either 2-hydroxyethyl methacrylate (HEMA), n-butyl methacrylate (BMA), or N-isopropyl acrylamide (NIPAAm) to create a barrier membrane. Control of plasma parameters changed the cross linking of this thin, conformal barrier, and produced different release rates of the active agents from the matrix. Biologically active echistatin and hirudin were delivered successfully, but some matrices exhibited a limited reduction in release rate due to osmotic rupturing of the matrix and coating. For RGDSGY-containing matrices, the reduction in release rate with RFGD plasma coating was greatest for matrices with PEG excipients of 10,000 and 20,000 molecular weight."],"dc:identifier.uri":["http://hdl.handle.net/1773/17089"],"dc:language.iso":["en_US"],"dc:publisher":["University of Washington Graduate School"],"dc:rights":["Copyright is held by the individual authors."],"dc:subject":["platelet thrombin BioSpan elastomer peptide bovine RFGD implanted biomaterials"],"dc:title":["Antithrombotic Peptide Delivery from Glow-Discharge Plasma-Coated Controlled Release Matrices"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:07:44Z"}