{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/20247"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/20247","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"A Determination of the Mass of the Deuteron","abstract":"We have measured the atomic mass of the deuteron relative to the calibration <super>12</super>C<super>6+</super> and <super>12</super>C<super>4+</super> ions and arrived at a value of 2 014 101 778 052 (40) pu for the mass of deuterium and 2 013 553 212 744 (40) pu for the mass of the deuteron. The spectroscopy was performed in the new University of Washington Penning Trap Mass Spectrometer (UW-PTMS). The measurement was made by using the experiment to make a very accurate determination of the cyclotron frequency of a deuteron isolated in a Penning trap, followed by the cyclotron frequency of a carbon calibration ion, isolated at the same place in that same trap. The ratio of the cyclotron frequencies is inversely proportional to the ratio of the two ion's mass-to-charge ratio after systematic corrections are made. The deuteron mass along with the proton mass, which also has its best measurement at the UW-PTMS, can be used with the deuteron binding energy[20] to refine the neutron mass to m<sub>n</sub>= 1 008 664 916 018 (435) pu. In addition to discussing the physics of our penning trap spectrometer and the systematic corrections necessary to obtain a mass ratio, improvements to the spectrometer will be described that were used in the deuteron measurement as well as improvements that were made later for future measurements.","abstract_html":"We have measured the atomic mass of the deuteron relative to the calibration &lt;super&gt;12&lt;/super&gt;C&lt;super&gt;6+&lt;/super&gt; and &lt;super&gt;12&lt;/super&gt;C&lt;super&gt;4+&lt;/super&gt; ions and arrived at a value of 2 014 101 778 052 (40) pu for the mass of deuterium and 2 013 553 212 744 (40) pu for the mass of the deuteron. The spectroscopy was performed in the new University of Washington Penning Trap Mass Spectrometer (UW-PTMS). The measurement was made by using the experiment to make a very accurate determination of the cyclotron frequency of a deuteron isolated in a Penning trap, followed by the cyclotron frequency of a carbon calibration ion, isolated at the same place in that same trap. The ratio of the cyclotron frequencies is inversely proportional to the ratio of the two ion&#x27;s mass-to-charge ratio after systematic corrections are made. The deuteron mass along with the proton mass, which also has its best measurement at the UW-PTMS, can be used with the deuteron binding energy[20] to refine the neutron mass to m&lt;sub&gt;n&lt;/sub&gt;= 1 008 664 916 018 (435) pu. In addition to discussing the physics of our penning trap spectrometer and the systematic corrections necessary to obtain a mass ratio, improvements to the spectrometer will be described that were used in the deuteron measurement as well as improvements that were made later for future measurements.","abstract_has_math":false,"creators":["Zafonte, Steven Leo"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Van Dyck, Robert S"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-08-10","date_published":"2012-08-10","updated_at":"2026-11-18T20:02:23Z","subjects":["Deuterium; Deuteron; Deuteron Mass; Mass Spectroscopy; Neutron Mass; Penning Trap","Physics"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/20247","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/20247","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F20247","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Van Dyck, Robert S"]},{"key":"dc:creator","label":"Author","values":["Zafonte, Steven Leo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-10T17:36:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-10T17:36:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-08-10"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Deuterium; Deuteron; Deuteron Mass; Mass Spectroscopy; Neutron Mass; Penning Trap"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Zafonte_washington_0250E_10101.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/20247"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--University of Washington, 2012"]},{"key":"dc:description.abstract","label":"Abstract","values":["We have measured the atomic mass of the deuteron relative to the calibration <super>12</super>C<super>6+</super> and <super>12</super>C<super>4+</super> ions and arrived at a value of 2 014 101 778 052 (40) pu for the mass of deuterium and 2 013 553 212 744 (40) pu for the mass of the deuteron. The spectroscopy was performed in the new University of Washington Penning Trap Mass Spectrometer (UW-PTMS). The measurement was made by using the experiment to make a very accurate determination of the cyclotron frequency of a deuteron isolated in a Penning trap, followed by the cyclotron frequency of a carbon calibration ion, isolated at the same place in that same trap. The ratio of the cyclotron frequencies is inversely proportional to the ratio of the two ion's mass-to-charge ratio after systematic corrections are made. The deuteron mass along with the proton mass, which also has its best measurement at the UW-PTMS, can be used with the deuteron binding energy[20] to refine the neutron mass to m<sub>n</sub>= 1 008 664 916 018 (435) pu. In addition to discussing the physics of our penning trap spectrometer and the systematic corrections necessary to obtain a mass ratio, improvements to the spectrometer will be described that were used in the deuteron measurement as well as improvements that were made later for future measurements."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["No embargo"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Determination of the Mass of the Deuteron"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Van Dyck, Robert S"],"dc:creator":["Zafonte, Steven Leo"],"dc:date.accessioned":["2012-08-10T17:36:44Z"],"dc:date.available":["2012-08-10T17:36:44Z"],"dc:date.issued":["2012-08-10"],"dc:date.submitted":["2012"],"dc:description":["Thesis (Ph.D.)--University of Washington, 2012"],"dc:description.abstract":["We have measured the atomic mass of the deuteron relative to the calibration <super>12</super>C<super>6+</super> and <super>12</super>C<super>4+</super> ions and arrived at a value of 2 014 101 778 052 (40) pu for the mass of deuterium and 2 013 553 212 744 (40) pu for the mass of the deuteron. The spectroscopy was performed in the new University of Washington Penning Trap Mass Spectrometer (UW-PTMS). The measurement was made by using the experiment to make a very accurate determination of the cyclotron frequency of a deuteron isolated in a Penning trap, followed by the cyclotron frequency of a carbon calibration ion, isolated at the same place in that same trap. The ratio of the cyclotron frequencies is inversely proportional to the ratio of the two ion's mass-to-charge ratio after systematic corrections are made. The deuteron mass along with the proton mass, which also has its best measurement at the UW-PTMS, can be used with the deuteron binding energy[20] to refine the neutron mass to m<sub>n</sub>= 1 008 664 916 018 (435) pu. In addition to discussing the physics of our penning trap spectrometer and the systematic corrections necessary to obtain a mass ratio, improvements to the spectrometer will be described that were used in the deuteron measurement as well as improvements that were made later for future measurements."],"dc:embargo.terms":["No embargo"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Zafonte_washington_0250E_10101.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/20247"],"dc:language.iso":["en_US"],"dc:rights":["Copyright is held by the individual authors."],"dc:subject":["Deuterium; Deuteron; Deuteron Mass; Mass Spectroscopy; Neutron Mass; Penning Trap"],"dc:subject.other":["Physics"],"dc:title":["A Determination of the Mass of the Deuteron"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:02:23Z"}