{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/23342"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/23342","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Evaluation of a CD4-aptamer for Flow Cytometry-based Enumeration of T-cell Subsets","abstract":"Introduction: Aptamers are engineered oligonucleotides that can be selected to bind with high specificity and affinity. As aptamers are cost-effective (estimated to be ~1,000-fold cheaper than antibodies) and also temperature-stable, aptamers may be useful in resource-limited settings for T-cell subset quantification. Here, we evaluated the performance characteristics of a CD4 aptamer for T-cell subset quantification. Methods: A CD4-biotinylated-streptavidin-PE aptamer provided by SomaLogic, Boulder, CO was combined with CD3-PC5, CD8-ECD and CD45-FITC antibodies in the multicolor flow cytometric assay; a CD4-A594 antibody was also added as an internal control for the CD4 aptamer. Residual patient samples were evaluated using the aptamer versus antibody reagents. Both the proportion of CD4 T cell and absolute CD4 T cell count were analyzed to evaluate the clinical performance of the aptamer reagent. Results and Conclusion: The CD4 aptamer showed comparable results to the established single platform method, which uses CYTO-STAT reagent (CD45F/CD4RD1/CD8ECD/CD3PC5) and an FC-500 flow cytometry system, with r2 >0.92 of CD4 T-cell% measurement,. Further, both the percentage of CD4 T cells and absolute T-cell count showed excellent agreement over the range of T cell proportions (8.6% to 50%) and absolute T-cell counts (150 cells/ul to 1342 cells/ul) as assessed by the CD4 aptamer as compared to an internal CD4-A594 antibody control, with r2 >0.99 and 9 cells /ul in mean difference. Our results suggest that a CD4 aptamer can perform comparably to an established CD4 antibody for CD4 T-cell subset quantitation and supports further development of aptamers as potential cost-effective reagents in resource-limited regions.","abstract_html":"Introduction: Aptamers are engineered oligonucleotides that can be selected to bind with high specificity and affinity. As aptamers are cost-effective (estimated to be ~1,000-fold cheaper than antibodies) and also temperature-stable, aptamers may be useful in resource-limited settings for T-cell subset quantification. Here, we evaluated the performance characteristics of a CD4 aptamer for T-cell subset quantification. Methods: A CD4-biotinylated-streptavidin-PE aptamer provided by SomaLogic, Boulder, CO was combined with CD3-PC5, CD8-ECD and CD45-FITC antibodies in the multicolor flow cytometric assay; a CD4-A594 antibody was also added as an internal control for the CD4 aptamer. Residual patient samples were evaluated using the aptamer versus antibody reagents. Both the proportion of CD4 T cell and absolute CD4 T cell count were analyzed to evaluate the clinical performance of the aptamer reagent. Results and Conclusion: The CD4 aptamer showed comparable results to the established single platform method, which uses CYTO-STAT reagent (CD45F/CD4RD1/CD8ECD/CD3PC5) and an FC-500 flow cytometry system, with r2 &gt;0.92 of CD4 T-cell% measurement,. Further, both the percentage of CD4 T cells and absolute T-cell count showed excellent agreement over the range of T cell proportions (8.6% to 50%) and absolute T-cell counts (150 cells/ul to 1342 cells/ul) as assessed by the CD4 aptamer as compared to an internal CD4-A594 antibody control, with r2 &gt;0.99 and 9 cells /ul in mean difference. Our results suggest that a CD4 aptamer can perform comparably to an established CD4 antibody for CD4 T-cell subset quantitation and supports further development of aptamers as potential cost-effective reagents in resource-limited regions.","abstract_has_math":false,"creators":["Huang, Hsin-Hsuan"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Wu, David"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-07-25","date_published":"2013-07-25","updated_at":"2026-11-18T20:04:48Z","subjects":["Aptamer; CD4 Counts; Flow Cytometry","Medicine","Health sciences","laboratory medicine"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/23342","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/23342","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F23342","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wu, David"]},{"key":"dc:creator","label":"Author","values":["Huang, Hsin-Hsuan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-07-25T17:45:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-07-25T17:45:24Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-07-25"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2013"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aptamer; CD4 Counts; Flow Cytometry"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Medicine","Health sciences","laboratory medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Huang_washington_0250O_11895.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/23342"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2013"]},{"key":"dc:description.abstract","label":"Abstract","values":["Introduction: Aptamers are engineered oligonucleotides that can be selected to bind with high specificity and affinity. As aptamers are cost-effective (estimated to be ~1,000-fold cheaper than antibodies) and also temperature-stable, aptamers may be useful in resource-limited settings for T-cell subset quantification. Here, we evaluated the performance characteristics of a CD4 aptamer for T-cell subset quantification. Methods: A CD4-biotinylated-streptavidin-PE aptamer provided by SomaLogic, Boulder, CO was combined with CD3-PC5, CD8-ECD and CD45-FITC antibodies in the multicolor flow cytometric assay; a CD4-A594 antibody was also added as an internal control for the CD4 aptamer. Residual patient samples were evaluated using the aptamer versus antibody reagents. Both the proportion of CD4 T cell and absolute CD4 T cell count were analyzed to evaluate the clinical performance of the aptamer reagent. Results and Conclusion: The CD4 aptamer showed comparable results to the established single platform method, which uses CYTO-STAT reagent (CD45F/CD4RD1/CD8ECD/CD3PC5) and an FC-500 flow cytometry system, with r2 >0.92 of CD4 T-cell% measurement,. Further, both the percentage of CD4 T cells and absolute T-cell count showed excellent agreement over the range of T cell proportions (8.6% to 50%) and absolute T-cell counts (150 cells/ul to 1342 cells/ul) as assessed by the CD4 aptamer as compared to an internal CD4-A594 antibody control, with r2 >0.99 and 9 cells /ul in mean difference. Our results suggest that a CD4 aptamer can perform comparably to an established CD4 antibody for CD4 T-cell subset quantitation and supports further development of aptamers as potential cost-effective reagents in resource-limited regions."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["No embargo"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Evaluation of a CD4-aptamer for Flow Cytometry-based Enumeration of T-cell Subsets"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wu, David"],"dc:creator":["Huang, Hsin-Hsuan"],"dc:date.accessioned":["2013-07-25T17:45:24Z"],"dc:date.available":["2013-07-25T17:45:24Z"],"dc:date.issued":["2013-07-25"],"dc:date.submitted":["2013"],"dc:description":["Thesis (Master's)--University of Washington, 2013"],"dc:description.abstract":["Introduction: Aptamers are engineered oligonucleotides that can be selected to bind with high specificity and affinity. As aptamers are cost-effective (estimated to be ~1,000-fold cheaper than antibodies) and also temperature-stable, aptamers may be useful in resource-limited settings for T-cell subset quantification. Here, we evaluated the performance characteristics of a CD4 aptamer for T-cell subset quantification. Methods: A CD4-biotinylated-streptavidin-PE aptamer provided by SomaLogic, Boulder, CO was combined with CD3-PC5, CD8-ECD and CD45-FITC antibodies in the multicolor flow cytometric assay; a CD4-A594 antibody was also added as an internal control for the CD4 aptamer. Residual patient samples were evaluated using the aptamer versus antibody reagents. Both the proportion of CD4 T cell and absolute CD4 T cell count were analyzed to evaluate the clinical performance of the aptamer reagent. Results and Conclusion: The CD4 aptamer showed comparable results to the established single platform method, which uses CYTO-STAT reagent (CD45F/CD4RD1/CD8ECD/CD3PC5) and an FC-500 flow cytometry system, with r2 >0.92 of CD4 T-cell% measurement,. Further, both the percentage of CD4 T cells and absolute T-cell count showed excellent agreement over the range of T cell proportions (8.6% to 50%) and absolute T-cell counts (150 cells/ul to 1342 cells/ul) as assessed by the CD4 aptamer as compared to an internal CD4-A594 antibody control, with r2 >0.99 and 9 cells /ul in mean difference. Our results suggest that a CD4 aptamer can perform comparably to an established CD4 antibody for CD4 T-cell subset quantitation and supports further development of aptamers as potential cost-effective reagents in resource-limited regions."],"dc:embargo.terms":["No embargo"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Huang_washington_0250O_11895.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/23342"],"dc:language.iso":["en_US"],"dc:rights":["Copyright is held by the individual authors."],"dc:subject":["Aptamer; CD4 Counts; Flow Cytometry"],"dc:subject.other":["Medicine","Health sciences","laboratory medicine"],"dc:title":["Evaluation of a CD4-aptamer for Flow Cytometry-based Enumeration of T-cell Subsets"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:04:48Z"}