{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/26346"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/26346","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Occupation and Computed Tomography Measurements of Chronic Obstructive Pulmonary Disease","abstract":"Introduction Occupational exposures have been linked to the development of chronic obstructive pulmonary disease (COPD). However, there are no studies reporting associations between occupation and computed tomography (CT) measures of COPD, such as airway wall thickness and lung density. Methods We analyzed data from a cross-sectional hospital and population-based study of current and past smokers conducted in Bergen, Norway between 2003 and 2005. 951 subjects completed an occupational questionnaire and underwent chest CTs to evaluate lung density (% low attenuation areas - %LAA950) and airway wall thickness (AWT) as a measure of chronic bronchitis. An industrial hygienist assigned a categorical dust exposure measure, 0 (none, n=444), 1 (low, n=308), 2 (medium, n=129) or 3 (high, n=50), based on job title and work type. We assessed the relationship between dust exposure and CT measures using multivariable regression, adjusting for age, sex, smoking and percent total lung capacity (airway obstruction-adjusted) as a measure of breath hold on CT. Results When compared to no dust exposure, the three dust exposure categories had a 20% (0.99%, 46%), 54% (18%, 102%), and 33% (0.92%, 93%) increase in geometric mean %LAA950, respectively, after adjusting for covariates. This suggests more emphysematous change in the dust exposure categories. When testing the association between dust exposure and AWT, the other COPD phenotype, the high dust category had a mean 0.092mm (.002, .181) greater AWT compared to no dust exposure, after adjusting for covariates. Conclusion Dust exposure, as defined by occupational title and work type, was associated with more areas of low lung density, reflecting more lung emphysema. Lack of power in the high dust category limited the ability to detect a statistically significant dose-response relationship through all levels of dust exposure. The association of high dust exposure with airway wall thickness suggests that there is an association with chronic bronchitis at high dust levels only. Future studies using a job exposure matrix may allow more precise exposure estimation and quantification of the associations with CT measures of COPD.","abstract_html":"Introduction Occupational exposures have been linked to the development of chronic obstructive pulmonary disease (COPD). However, there are no studies reporting associations between occupation and computed tomography (CT) measures of COPD, such as airway wall thickness and lung density. Methods We analyzed data from a cross-sectional hospital and population-based study of current and past smokers conducted in Bergen, Norway between 2003 and 2005. 951 subjects completed an occupational questionnaire and underwent chest CTs to evaluate lung density (% low attenuation areas - %LAA950) and airway wall thickness (AWT) as a measure of chronic bronchitis. An industrial hygienist assigned a categorical dust exposure measure, 0 (none, n=444), 1 (low, n=308), 2 (medium, n=129) or 3 (high, n=50), based on job title and work type. We assessed the relationship between dust exposure and CT measures using multivariable regression, adjusting for age, sex, smoking and percent total lung capacity (airway obstruction-adjusted) as a measure of breath hold on CT. Results When compared to no dust exposure, the three dust exposure categories had a 20% (0.99%, 46%), 54% (18%, 102%), and 33% (0.92%, 93%) increase in geometric mean %LAA950, respectively, after adjusting for covariates. This suggests more emphysematous change in the dust exposure categories. When testing the association between dust exposure and AWT, the other COPD phenotype, the high dust category had a mean 0.092mm (.002, .181) greater AWT compared to no dust exposure, after adjusting for covariates. Conclusion Dust exposure, as defined by occupational title and work type, was associated with more areas of low lung density, reflecting more lung emphysema. Lack of power in the high dust category limited the ability to detect a statistically significant dose-response relationship through all levels of dust exposure. The association of high dust exposure with airway wall thickness suggests that there is an association with chronic bronchitis at high dust levels only. Future studies using a job exposure matrix may allow more precise exposure estimation and quantification of the associations with CT measures of COPD.","abstract_has_math":false,"creators":["Kimball, Stanley Jarman"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Vedal, Sverre"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-10-13","date_published":"2014-10-13","updated_at":"2026-11-18T20:06:15Z","subjects":["Occupational health","Medicine","environmental health"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Kimball_washington_0250O_13281.pdf"],"render_values":[{"text":"Kimball_washington_0250O_13281.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1773/26346","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1773/26346","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F26346","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Vedal, Sverre"]},{"key":"dc:creator","label":"Author","values":["Kimball, Stanley Jarman"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-10-13T19:58:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-12-14T17:55:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-10-13"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Occupational health","Medicine","environmental health"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Kimball_washington_0250O_13281.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/26346"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2014"]},{"key":"dc:description.abstract","label":"Abstract","values":["Introduction Occupational exposures have been linked to the development of chronic obstructive pulmonary disease (COPD). However, there are no studies reporting associations between occupation and computed tomography (CT) measures of COPD, such as airway wall thickness and lung density. Methods We analyzed data from a cross-sectional hospital and population-based study of current and past smokers conducted in Bergen, Norway between 2003 and 2005. 951 subjects completed an occupational questionnaire and underwent chest CTs to evaluate lung density (% low attenuation areas - %LAA950) and airway wall thickness (AWT) as a measure of chronic bronchitis. An industrial hygienist assigned a categorical dust exposure measure, 0 (none, n=444), 1 (low, n=308), 2 (medium, n=129) or 3 (high, n=50), based on job title and work type. We assessed the relationship between dust exposure and CT measures using multivariable regression, adjusting for age, sex, smoking and percent total lung capacity (airway obstruction-adjusted) as a measure of breath hold on CT. Results When compared to no dust exposure, the three dust exposure categories had a 20% (0.99%, 46%), 54% (18%, 102%), and 33% (0.92%, 93%) increase in geometric mean %LAA950, respectively, after adjusting for covariates. This suggests more emphysematous change in the dust exposure categories. When testing the association between dust exposure and AWT, the other COPD phenotype, the high dust category had a mean 0.092mm (.002, .181) greater AWT compared to no dust exposure, after adjusting for covariates. Conclusion Dust exposure, as defined by occupational title and work type, was associated with more areas of low lung density, reflecting more lung emphysema. Lack of power in the high dust category limited the ability to detect a statistically significant dose-response relationship through all levels of dust exposure. The association of high dust exposure with airway wall thickness suggests that there is an association with chronic bronchitis at high dust levels only. Future studies using a job exposure matrix may allow more precise exposure estimation and quantification of the associations with CT measures of COPD."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Restrict to UW for 1 year -- then make Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Occupation and Computed Tomography Measurements of Chronic Obstructive Pulmonary Disease"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Vedal, Sverre"],"dc:creator":["Kimball, Stanley Jarman"],"dc:date.accessioned":["2014-10-13T19:58:54Z"],"dc:date.available":["2015-12-14T17:55:49Z"],"dc:date.issued":["2014-10-13"],"dc:date.submitted":["2014"],"dc:description":["Thesis (Master's)--University of Washington, 2014"],"dc:description.abstract":["Introduction Occupational exposures have been linked to the development of chronic obstructive pulmonary disease (COPD). However, there are no studies reporting associations between occupation and computed tomography (CT) measures of COPD, such as airway wall thickness and lung density. Methods We analyzed data from a cross-sectional hospital and population-based study of current and past smokers conducted in Bergen, Norway between 2003 and 2005. 951 subjects completed an occupational questionnaire and underwent chest CTs to evaluate lung density (% low attenuation areas - %LAA950) and airway wall thickness (AWT) as a measure of chronic bronchitis. An industrial hygienist assigned a categorical dust exposure measure, 0 (none, n=444), 1 (low, n=308), 2 (medium, n=129) or 3 (high, n=50), based on job title and work type. We assessed the relationship between dust exposure and CT measures using multivariable regression, adjusting for age, sex, smoking and percent total lung capacity (airway obstruction-adjusted) as a measure of breath hold on CT. Results When compared to no dust exposure, the three dust exposure categories had a 20% (0.99%, 46%), 54% (18%, 102%), and 33% (0.92%, 93%) increase in geometric mean %LAA950, respectively, after adjusting for covariates. This suggests more emphysematous change in the dust exposure categories. When testing the association between dust exposure and AWT, the other COPD phenotype, the high dust category had a mean 0.092mm (.002, .181) greater AWT compared to no dust exposure, after adjusting for covariates. Conclusion Dust exposure, as defined by occupational title and work type, was associated with more areas of low lung density, reflecting more lung emphysema. Lack of power in the high dust category limited the ability to detect a statistically significant dose-response relationship through all levels of dust exposure. The association of high dust exposure with airway wall thickness suggests that there is an association with chronic bronchitis at high dust levels only. Future studies using a job exposure matrix may allow more precise exposure estimation and quantification of the associations with CT measures of COPD."],"dc:embargo.terms":["Restrict to UW for 1 year -- then make Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Kimball_washington_0250O_13281.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/26346"],"dc:language.iso":["en_US"],"dc:rights":["Copyright is held by the individual authors."],"dc:subject.other":["Occupational health","Medicine","environmental health"],"dc:title":["Occupation and Computed Tomography Measurements of Chronic Obstructive Pulmonary Disease"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:06:15Z"}