{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/26898"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/26898","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Minimally invasive micro-fabricated sensor for accurate measurement of thermal properties of biomaterials and solutions","abstract":"Accurate measurement of thermal properties of biomaterials is very important in predicting the optimum cooling rate; which influences largely the survival rate of tissues during freezing and thawing. But the current methods compromise either on the accuracy or the ability to accommodate different sample size. Hence we introduce a micro thermal sensor with superior features: excellent data repeatability, accuracy, compatibility, mass produce and reduced calibration efforts to measure thermal properties of bio-samples. We present two variants of the sensor: a single probe and a multi-probe; with the latter having promising innovative application in detecting thermal boundaries of tissues using their conductivities. The micro sensor has been utilized to measure thermal properties of pure DMSO, Ethylene glycol, Glycerol and commonly used CPA solution mixtures: 10 % (V/V) DMSO, 1.5 M Ethylene glycol, 1.5 M Glycerol and 40% (W/V) Glycerol, all in 0.9% (W/V) aqueous Nacl.","abstract_html":"Accurate measurement of thermal properties of biomaterials is very important in predicting the optimum cooling rate; which influences largely the survival rate of tissues during freezing and thawing. But the current methods compromise either on the accuracy or the ability to accommodate different sample size. Hence we introduce a micro thermal sensor with superior features: excellent data repeatability, accuracy, compatibility, mass produce and reduced calibration efforts to measure thermal properties of bio-samples. We present two variants of the sensor: a single probe and a multi-probe; with the latter having promising innovative application in detecting thermal boundaries of tissues using their conductivities. The micro sensor has been utilized to measure thermal properties of pure DMSO, Ethylene glycol, Glycerol and commonly used CPA solution mixtures: 10 % (V/V) DMSO, 1.5 M Ethylene glycol, 1.5 M Glycerol and 40% (W/V) Glycerol, all in 0.9% (W/V) aqueous Nacl.","abstract_has_math":false,"creators":["Kaliappan Sekar, Praveen"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Gao, Dayong"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-10-20","date_published":"2014-10-20","updated_at":"2026-11-18T20:08:54Z","subjects":["Biosensors; Cryobiology; Cryoprotective Agents (CPA); Lithography; MEMS; Transient hot wire","Mechanical engineering","Biomedical engineering","Nanotechnology"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/26898","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/26898","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F26898","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gao, Dayong"]},{"key":"dc:creator","label":"Author","values":["Kaliappan Sekar, Praveen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-10-20T22:22:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-12-14T17:55:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-10-20"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biosensors; Cryobiology; Cryoprotective Agents (CPA); Lithography; MEMS; Transient hot wire"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Mechanical engineering","Biomedical engineering","Nanotechnology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["KaliappanSekar_washington_0250O_13176.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/26898"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2014"]},{"key":"dc:description.abstract","label":"Abstract","values":["Accurate measurement of thermal properties of biomaterials is very important in predicting the optimum cooling rate; which influences largely the survival rate of tissues during freezing and thawing. But the current methods compromise either on the accuracy or the ability to accommodate different sample size. Hence we introduce a micro thermal sensor with superior features: excellent data repeatability, accuracy, compatibility, mass produce and reduced calibration efforts to measure thermal properties of bio-samples. We present two variants of the sensor: a single probe and a multi-probe; with the latter having promising innovative application in detecting thermal boundaries of tissues using their conductivities. The micro sensor has been utilized to measure thermal properties of pure DMSO, Ethylene glycol, Glycerol and commonly used CPA solution mixtures: 10 % (V/V) DMSO, 1.5 M Ethylene glycol, 1.5 M Glycerol and 40% (W/V) Glycerol, all in 0.9% (W/V) aqueous Nacl."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Delay release for 1 year -- then make Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Minimally invasive micro-fabricated sensor for accurate measurement of thermal properties of biomaterials and solutions"]},{"key":"others:access_status","label":"Others Access Status","values":["restricted"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gao, Dayong"],"dc:creator":["Kaliappan Sekar, Praveen"],"dc:date.accessioned":["2014-10-20T22:22:31Z"],"dc:date.available":["2015-12-14T17:55:57Z"],"dc:date.issued":["2014-10-20"],"dc:date.submitted":["2014"],"dc:description":["Thesis (Master's)--University of Washington, 2014"],"dc:description.abstract":["Accurate measurement of thermal properties of biomaterials is very important in predicting the optimum cooling rate; which influences largely the survival rate of tissues during freezing and thawing. But the current methods compromise either on the accuracy or the ability to accommodate different sample size. Hence we introduce a micro thermal sensor with superior features: excellent data repeatability, accuracy, compatibility, mass produce and reduced calibration efforts to measure thermal properties of bio-samples. We present two variants of the sensor: a single probe and a multi-probe; with the latter having promising innovative application in detecting thermal boundaries of tissues using their conductivities. The micro sensor has been utilized to measure thermal properties of pure DMSO, Ethylene glycol, Glycerol and commonly used CPA solution mixtures: 10 % (V/V) DMSO, 1.5 M Ethylene glycol, 1.5 M Glycerol and 40% (W/V) Glycerol, all in 0.9% (W/V) aqueous Nacl."],"dc:embargo.terms":["Delay release for 1 year -- then make Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["KaliappanSekar_washington_0250O_13176.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/26898"],"dc:language.iso":["en_US"],"dc:rights":["Copyright is held by the individual authors."],"dc:subject":["Biosensors; Cryobiology; Cryoprotective Agents (CPA); Lithography; MEMS; Transient hot wire"],"dc:subject.other":["Mechanical engineering","Biomedical engineering","Nanotechnology"],"dc:title":["Minimally invasive micro-fabricated sensor for accurate measurement of thermal properties of biomaterials and solutions"],"dc:type":["Thesis"],"others:access_status":["restricted"]},"updated_at":"2026-11-18T20:08:54Z"}