{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/27462"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/27462","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Electronic Molecular Detection: from Proteins to Neurons","abstract":"This dissertation presents my research investigating a number of microscale devices designed to interact with various biological systems. First, I describe the development of nanoscale electronic sensor devices for quantitative detection of biomolecule concentrations in liquids. Two sensor designs are discussed - one using semiconducting nanowires and another employing a novel fluid nanochannel layout. Microfabrication and sensor performance optimization methods are discussed, culminating with an overview of molecular sensing results. Second, I describe an effort undertaken in support of a project aimed at creating a contact lens based glucose sensor. A miniature version of the sensor was created and tested in-vivo, inside a rabbit's eye, using the intraocular fluid as an ersatz tear fluid. Also, described is an anatomically correct model of a human eye, complete with moving eyelids and working tear ducts, used for testing contact lens sensors in a life-like environment. This effort has helped focus further development of the contact lens sensor project on solving the issue of chemical interference in in-vivo environments. Lastly, I describe design, microfabrication and in-vivo testing of implantable, highly flexible, non-invasive active neural electrode arrays used in an effort to create a fully implantable and wirelessly powered brain-computer interface system. Multiple array geometries for both subcranial and intraspinal implantation as well as their in-vitro and in-vivo performance are discussed. Ultimately, I present an active electrode array assembled with four neural signal amplifiers, using a novel two-sided parylene process.","abstract_html":"This dissertation presents my research investigating a number of microscale devices designed to interact with various biological systems. First, I describe the development of nanoscale electronic sensor devices for quantitative detection of biomolecule concentrations in liquids. Two sensor designs are discussed - one using semiconducting nanowires and another employing a novel fluid nanochannel layout. Microfabrication and sensor performance optimization methods are discussed, culminating with an overview of molecular sensing results. Second, I describe an effort undertaken in support of a project aimed at creating a contact lens based glucose sensor. A miniature version of the sensor was created and tested in-vivo, inside a rabbit&#x27;s eye, using the intraocular fluid as an ersatz tear fluid. Also, described is an anatomically correct model of a human eye, complete with moving eyelids and working tear ducts, used for testing contact lens sensors in a life-like environment. This effort has helped focus further development of the contact lens sensor project on solving the issue of chemical interference in in-vivo environments. Lastly, I describe design, microfabrication and in-vivo testing of implantable, highly flexible, non-invasive active neural electrode arrays used in an effort to create a fully implantable and wirelessly powered brain-computer interface system. Multiple array geometries for both subcranial and intraspinal implantation as well as their in-vitro and in-vivo performance are discussed. Ultimately, I present an active electrode array assembled with four neural signal amplifiers, using a novel two-sided parylene process.","abstract_has_math":false,"creators":["Afanasiev, Andrei"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Böhringer, Karl"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-02-24","date_published":"2015-02-24","updated_at":"2026-11-19T10:18:15Z","subjects":["Electrical engineering"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/27462","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/27462","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F27462","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Böhringer, Karl"]},{"key":"dc:creator","label":"Author","values":["Afanasiev, Andrei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-02-24T17:33:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-02-24"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2016-02-24T17:33:57Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Electrical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Afanasiev_washington_0250E_13801.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/27462"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--University of Washington, 2014"]},{"key":"dc:description.abstract","label":"Abstract","values":["This dissertation presents my research investigating a number of microscale devices designed to interact with various biological systems. First, I describe the development of nanoscale electronic sensor devices for quantitative detection of biomolecule concentrations in liquids. Two sensor designs are discussed - one using semiconducting nanowires and another employing a novel fluid nanochannel layout. Microfabrication and sensor performance optimization methods are discussed, culminating with an overview of molecular sensing results. Second, I describe an effort undertaken in support of a project aimed at creating a contact lens based glucose sensor. A miniature version of the sensor was created and tested in-vivo, inside a rabbit's eye, using the intraocular fluid as an ersatz tear fluid. Also, described is an anatomically correct model of a human eye, complete with moving eyelids and working tear ducts, used for testing contact lens sensors in a life-like environment. This effort has helped focus further development of the contact lens sensor project on solving the issue of chemical interference in in-vivo environments. Lastly, I describe design, microfabrication and in-vivo testing of implantable, highly flexible, non-invasive active neural electrode arrays used in an effort to create a fully implantable and wirelessly powered brain-computer interface system. Multiple array geometries for both subcranial and intraspinal implantation as well as their in-vitro and in-vivo performance are discussed. Ultimately, I present an active electrode array assembled with four neural signal amplifiers, using a novel two-sided parylene process."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Delay release for 1 year -- then make Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Electronic Molecular Detection: from Proteins to Neurons"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Böhringer, Karl"],"dc:creator":["Afanasiev, Andrei"],"dc:date.accessioned":["2015-02-24T17:33:57Z"],"dc:date.issued":["2015-02-24"],"dc:date.liftdate":["2016-02-24T17:33:57Z"],"dc:date.submitted":["2014"],"dc:description":["Thesis (Ph.D.)--University of Washington, 2014"],"dc:description.abstract":["This dissertation presents my research investigating a number of microscale devices designed to interact with various biological systems. First, I describe the development of nanoscale electronic sensor devices for quantitative detection of biomolecule concentrations in liquids. Two sensor designs are discussed - one using semiconducting nanowires and another employing a novel fluid nanochannel layout. Microfabrication and sensor performance optimization methods are discussed, culminating with an overview of molecular sensing results. Second, I describe an effort undertaken in support of a project aimed at creating a contact lens based glucose sensor. A miniature version of the sensor was created and tested in-vivo, inside a rabbit's eye, using the intraocular fluid as an ersatz tear fluid. Also, described is an anatomically correct model of a human eye, complete with moving eyelids and working tear ducts, used for testing contact lens sensors in a life-like environment. This effort has helped focus further development of the contact lens sensor project on solving the issue of chemical interference in in-vivo environments. Lastly, I describe design, microfabrication and in-vivo testing of implantable, highly flexible, non-invasive active neural electrode arrays used in an effort to create a fully implantable and wirelessly powered brain-computer interface system. Multiple array geometries for both subcranial and intraspinal implantation as well as their in-vitro and in-vivo performance are discussed. Ultimately, I present an active electrode array assembled with four neural signal amplifiers, using a novel two-sided parylene process."],"dc:embargo.terms":["Delay release for 1 year -- then make Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Afanasiev_washington_0250E_13801.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/27462"],"dc:language.iso":["en_US"],"dc:rights":["Copyright is held by the individual authors."],"dc:subject.other":["Electrical engineering"],"dc:title":["Electronic Molecular Detection: from Proteins to Neurons"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:18:15Z"}