{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/33579"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/33579","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Vibrotactile Sensory Feedback for Lower Limb Prostheses","abstract":"This dissertation focuses on understanding the limitations of a vibrotactile feedback system on the thigh. Due to the dynamic nature of the environment and time-sensitive information that need to be relayed to the user, it is important to know the strengths and weaknesses of implementing a vibrotactile system. Our data showed that vibrotactile stimuli does not provide the fastest reaction time when compared to visual and auditory stimuli. In addition, vibrotactile stimuli of the lower limb was most affected when walking was introduced. While investigating this issue, a systematic approach to understand human capability of spatially localizing perception was also developed. We found an interesting result that people were better at discriminating sensations mediolaterally than in the proximal/distal direction. Based on our results, the use of a sensory substitution system may not be feasible unless movements are predicted or time-sensitive information is not being communicated. However, the sensory effects of targeted muscle reinnervation could be leveraged to make a vibrotactile feedback system that provides natural feedback instead of using sensory substitution methods of feedback.","abstract_html":"This dissertation focuses on understanding the limitations of a vibrotactile feedback system on the thigh. Due to the dynamic nature of the environment and time-sensitive information that need to be relayed to the user, it is important to know the strengths and weaknesses of implementing a vibrotactile system. Our data showed that vibrotactile stimuli does not provide the fastest reaction time when compared to visual and auditory stimuli. In addition, vibrotactile stimuli of the lower limb was most affected when walking was introduced. While investigating this issue, a systematic approach to understand human capability of spatially localizing perception was also developed. We found an interesting result that people were better at discriminating sensations mediolaterally than in the proximal/distal direction. Based on our results, the use of a sensory substitution system may not be feasible unless movements are predicted or time-sensitive information is not being communicated. However, the sensory effects of targeted muscle reinnervation could be leveraged to make a vibrotactile feedback system that provides natural feedback instead of using sensory substitution methods of feedback.","abstract_has_math":false,"creators":["Jiang, Iris"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Hannaford, Blake"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-29","date_published":"2015-09-29","updated_at":"2026-11-18T20:04:48Z","subjects":["Lower limb prosthetics; Sensory feedback; Sensory perception","Biomedical engineering","bioengineering"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/33579","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/33579","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F33579","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hannaford, Blake"]},{"key":"dc:creator","label":"Author","values":["Jiang, Iris"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-29T17:57:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-29T17:57:33Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-09-29"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2015"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Lower limb prosthetics; Sensory feedback; Sensory perception"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Biomedical engineering","bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Jiang_washington_0250E_14743.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/33579"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--University of Washington, 2015"]},{"key":"dc:description.abstract","label":"Abstract","values":["This dissertation focuses on understanding the limitations of a vibrotactile feedback system on the thigh. Due to the dynamic nature of the environment and time-sensitive information that need to be relayed to the user, it is important to know the strengths and weaknesses of implementing a vibrotactile system. Our data showed that vibrotactile stimuli does not provide the fastest reaction time when compared to visual and auditory stimuli. In addition, vibrotactile stimuli of the lower limb was most affected when walking was introduced. While investigating this issue, a systematic approach to understand human capability of spatially localizing perception was also developed. We found an interesting result that people were better at discriminating sensations mediolaterally than in the proximal/distal direction. Based on our results, the use of a sensory substitution system may not be feasible unless movements are predicted or time-sensitive information is not being communicated. However, the sensory effects of targeted muscle reinnervation could be leveraged to make a vibrotactile feedback system that provides natural feedback instead of using sensory substitution methods of feedback."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Vibrotactile Sensory Feedback for Lower Limb Prostheses"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hannaford, Blake"],"dc:creator":["Jiang, Iris"],"dc:date.accessioned":["2015-09-29T17:57:33Z"],"dc:date.available":["2015-09-29T17:57:33Z"],"dc:date.issued":["2015-09-29"],"dc:date.submitted":["2015"],"dc:description":["Thesis (Ph.D.)--University of Washington, 2015"],"dc:description.abstract":["This dissertation focuses on understanding the limitations of a vibrotactile feedback system on the thigh. Due to the dynamic nature of the environment and time-sensitive information that need to be relayed to the user, it is important to know the strengths and weaknesses of implementing a vibrotactile system. Our data showed that vibrotactile stimuli does not provide the fastest reaction time when compared to visual and auditory stimuli. In addition, vibrotactile stimuli of the lower limb was most affected when walking was introduced. While investigating this issue, a systematic approach to understand human capability of spatially localizing perception was also developed. We found an interesting result that people were better at discriminating sensations mediolaterally than in the proximal/distal direction. Based on our results, the use of a sensory substitution system may not be feasible unless movements are predicted or time-sensitive information is not being communicated. However, the sensory effects of targeted muscle reinnervation could be leveraged to make a vibrotactile feedback system that provides natural feedback instead of using sensory substitution methods of feedback."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Jiang_washington_0250E_14743.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/33579"],"dc:language.iso":["en_US"],"dc:rights":["Copyright is held by the individual authors."],"dc:subject":["Lower limb prosthetics; Sensory feedback; Sensory perception"],"dc:subject.other":["Biomedical engineering","bioengineering"],"dc:title":["Vibrotactile Sensory Feedback for Lower Limb Prostheses"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:04:48Z"}