{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/33656"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/33656","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Advances in Instrumentation and Data Analysis Techniques for Increasing Peak Capacity and Peak Capacity Production in One and Two-Dimensional Gas Chromatography","abstract":"Techniques to substantially increase peak capacity (number of peaks per separation window) and peak capacity production (number of peaks produced per unit time) for one and two-dimensional gas chromatography are demonstrated. First, instrumental advances related to sample introduction and column heating rate are discussed. Rapid sample introduction to the chromatographic system was achieved with a thermal injection device to deliver ultra-narrow peaks onto the GC column. When compared to standard sample introduction, thermal injection can provide peaks that are ~10 times narrower which gives rise to peak capacities an order of magnitude larger when compared to traditional GC practice. To further increase peak capacity and peak capacity production, a low thermal mass (LTM) GC system operated at a heating rate of 250 °C/min was applied with thermal injection to produce a separation with a peak capacity of ~300 in 1 minute. Additionally, thermal injection was applied to a comprehensive two-dimensional gas chromatographic system coupled to time-of-flight mass spectrometry (GC × GC – TOFMS) to produce a separation with a peak capacity of ~6,000 in 6 minutes, affording a peak capacity production rate of ~1,000 peaks/minute. Second, a novel algorithmic approach for processing GC-TOFMS data is presented which can increase the peak capacity and peak capacity production values even further. The algorithm relies on GC-TOFMS data that is sampled with sufficient data density (> 100 points/peak) to accurately measure analyte peak widths, W, and retention times, tR. Separation visualization is made possible by transforming the data from a signal versus time format to a peak width versus retention time format. This is achieved by measuring the W and tR of each m/z for each analyte in the separation, followed by plotting of the data (W vs. tR) in a two-dimensional format. Plotting the data in this fashion allows for the visualization of pure and interfered m/z of analytes. Coupled with chemometric analysis allows for the deconvolution of poorly-resolved analytes down to a resolution, Rs = 0.03. The peak capacity of a 7 minute GC-TOFMS separation was increased from ~400 to ~10,000 using this technique.","abstract_html":"Techniques to substantially increase peak capacity (number of peaks per separation window) and peak capacity production (number of peaks produced per unit time) for one and two-dimensional gas chromatography are demonstrated. First, instrumental advances related to sample introduction and column heating rate are discussed. Rapid sample introduction to the chromatographic system was achieved with a thermal injection device to deliver ultra-narrow peaks onto the GC column. When compared to standard sample introduction, thermal injection can provide peaks that are ~10 times narrower which gives rise to peak capacities an order of magnitude larger when compared to traditional GC practice. To further increase peak capacity and peak capacity production, a low thermal mass (LTM) GC system operated at a heating rate of 250 °C/min was applied with thermal injection to produce a separation with a peak capacity of ~300 in 1 minute. Additionally, thermal injection was applied to a comprehensive two-dimensional gas chromatographic system coupled to time-of-flight mass spectrometry (GC × GC – TOFMS) to produce a separation with a peak capacity of ~6,000 in 6 minutes, affording a peak capacity production rate of ~1,000 peaks/minute. Second, a novel algorithmic approach for processing GC-TOFMS data is presented which can increase the peak capacity and peak capacity production values even further. The algorithm relies on GC-TOFMS data that is sampled with sufficient data density (&gt; 100 points/peak) to accurately measure analyte peak widths, W, and retention times, tR. Separation visualization is made possible by transforming the data from a signal versus time format to a peak width versus retention time format. This is achieved by measuring the W and tR of each m/z for each analyte in the separation, followed by plotting of the data (W vs. tR) in a two-dimensional format. Plotting the data in this fashion allows for the visualization of pure and interfered m/z of analytes. Coupled with chemometric analysis allows for the deconvolution of poorly-resolved analytes down to a resolution, Rs = 0.03. The peak capacity of a 7 minute GC-TOFMS separation was increased from ~400 to ~10,000 using this technique.","abstract_has_math":false,"creators":["Fitz, Brian David"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Synovec, Robert E"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-29","date_published":"2015-09-29","updated_at":"2026-11-18T20:06:36Z","subjects":["Data Analysis; Fast Gas Chromatography; Gas Chromatography Injection Methods; Peak Capacity; Peak Capacity Production; Two-Dimensional Gas Chromatography","Chemistry","Analytical chemistry"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/33656","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/33656","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F33656","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Synovec, Robert E"]},{"key":"dc:creator","label":"Author","values":["Fitz, Brian David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-29T17:59:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-29T17:59:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-09-29"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2015"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Data Analysis; Fast Gas Chromatography; Gas Chromatography Injection Methods; Peak Capacity; Peak Capacity Production; Two-Dimensional Gas Chromatography"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Chemistry","Analytical chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Fitz_washington_0250E_15005.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/33656"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--University of Washington, 2015"]},{"key":"dc:description.abstract","label":"Abstract","values":["Techniques to substantially increase peak capacity (number of peaks per separation window) and peak capacity production (number of peaks produced per unit time) for one and two-dimensional gas chromatography are demonstrated. First, instrumental advances related to sample introduction and column heating rate are discussed. Rapid sample introduction to the chromatographic system was achieved with a thermal injection device to deliver ultra-narrow peaks onto the GC column. When compared to standard sample introduction, thermal injection can provide peaks that are ~10 times narrower which gives rise to peak capacities an order of magnitude larger when compared to traditional GC practice. To further increase peak capacity and peak capacity production, a low thermal mass (LTM) GC system operated at a heating rate of 250 °C/min was applied with thermal injection to produce a separation with a peak capacity of ~300 in 1 minute. Additionally, thermal injection was applied to a comprehensive two-dimensional gas chromatographic system coupled to time-of-flight mass spectrometry (GC × GC – TOFMS) to produce a separation with a peak capacity of ~6,000 in 6 minutes, affording a peak capacity production rate of ~1,000 peaks/minute. Second, a novel algorithmic approach for processing GC-TOFMS data is presented which can increase the peak capacity and peak capacity production values even further. The algorithm relies on GC-TOFMS data that is sampled with sufficient data density (> 100 points/peak) to accurately measure analyte peak widths, W, and retention times, tR. Separation visualization is made possible by transforming the data from a signal versus time format to a peak width versus retention time format. This is achieved by measuring the W and tR of each m/z for each analyte in the separation, followed by plotting of the data (W vs. tR) in a two-dimensional format. Plotting the data in this fashion allows for the visualization of pure and interfered m/z of analytes. Coupled with chemometric analysis allows for the deconvolution of poorly-resolved analytes down to a resolution, Rs = 0.03. The peak capacity of a 7 minute GC-TOFMS separation was increased from ~400 to ~10,000 using this technique."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Advances in Instrumentation and Data Analysis Techniques for Increasing Peak Capacity and Peak Capacity Production in One and Two-Dimensional Gas Chromatography"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Synovec, Robert E"],"dc:creator":["Fitz, Brian David"],"dc:date.accessioned":["2015-09-29T17:59:34Z"],"dc:date.available":["2015-09-29T17:59:34Z"],"dc:date.issued":["2015-09-29"],"dc:date.submitted":["2015"],"dc:description":["Thesis (Ph.D.)--University of Washington, 2015"],"dc:description.abstract":["Techniques to substantially increase peak capacity (number of peaks per separation window) and peak capacity production (number of peaks produced per unit time) for one and two-dimensional gas chromatography are demonstrated. First, instrumental advances related to sample introduction and column heating rate are discussed. Rapid sample introduction to the chromatographic system was achieved with a thermal injection device to deliver ultra-narrow peaks onto the GC column. When compared to standard sample introduction, thermal injection can provide peaks that are ~10 times narrower which gives rise to peak capacities an order of magnitude larger when compared to traditional GC practice. To further increase peak capacity and peak capacity production, a low thermal mass (LTM) GC system operated at a heating rate of 250 °C/min was applied with thermal injection to produce a separation with a peak capacity of ~300 in 1 minute. Additionally, thermal injection was applied to a comprehensive two-dimensional gas chromatographic system coupled to time-of-flight mass spectrometry (GC × GC – TOFMS) to produce a separation with a peak capacity of ~6,000 in 6 minutes, affording a peak capacity production rate of ~1,000 peaks/minute. Second, a novel algorithmic approach for processing GC-TOFMS data is presented which can increase the peak capacity and peak capacity production values even further. The algorithm relies on GC-TOFMS data that is sampled with sufficient data density (> 100 points/peak) to accurately measure analyte peak widths, W, and retention times, tR. Separation visualization is made possible by transforming the data from a signal versus time format to a peak width versus retention time format. This is achieved by measuring the W and tR of each m/z for each analyte in the separation, followed by plotting of the data (W vs. tR) in a two-dimensional format. Plotting the data in this fashion allows for the visualization of pure and interfered m/z of analytes. Coupled with chemometric analysis allows for the deconvolution of poorly-resolved analytes down to a resolution, Rs = 0.03. The peak capacity of a 7 minute GC-TOFMS separation was increased from ~400 to ~10,000 using this technique."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Fitz_washington_0250E_15005.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/33656"],"dc:language.iso":["en_US"],"dc:rights":["Copyright is held by the individual authors."],"dc:subject":["Data Analysis; Fast Gas Chromatography; Gas Chromatography Injection Methods; Peak Capacity; Peak Capacity Production; Two-Dimensional Gas Chromatography"],"dc:subject.other":["Chemistry","Analytical chemistry"],"dc:title":["Advances in Instrumentation and Data Analysis Techniques for Increasing Peak Capacity and Peak Capacity Production in One and Two-Dimensional Gas Chromatography"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:06:36Z"}