{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/34052"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/34052","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Development of a 2D Mechanical Resonant Push-Pull Scanning Endoscope","abstract":"In recent years, miniature scanner technologies, including micro-electro-mechanical system (MEMS) scanners, have started to appear on the market. Most miniature scanner technologies utilize MEMS scanner mirrors. However, this approach has many limitations. In the meanwhile, a competing technology called fiber optic resonant scanner (FORS) has also been developed in order to obtain forward image. An off-the-shelf piezoelectric actuator at the base to create transverse vibrations of a resonating optical fiber has shown to be an effective method for generating 1D and 2D laser line scans. We previously developed a 2D micro image display device that utilized MEMS-based waveguide to replace the optical fiber, which can potentially overcome the size limitations of mirror-based display. In this research, an improved waveguide scanner system using a fully integrated MEMS-based push-pull actuator is presented. This prototype features monolithic integration of the waveguide, actuator, and light source, and removes the dependence on external actuators used by the previous design. The transmission efficiency is low and cantilever is slightly under tensile stress due to inherent imperfection in the process imperfection and tooling in fabrication. Nevertheless, 2D light scanning pattern is successfully demonstrated using 1D push-pull actuation.","abstract_html":"In recent years, miniature scanner technologies, including micro-electro-mechanical system (MEMS) scanners, have started to appear on the market. Most miniature scanner technologies utilize MEMS scanner mirrors. However, this approach has many limitations. In the meanwhile, a competing technology called fiber optic resonant scanner (FORS) has also been developed in order to obtain forward image. An off-the-shelf piezoelectric actuator at the base to create transverse vibrations of a resonating optical fiber has shown to be an effective method for generating 1D and 2D laser line scans. We previously developed a 2D micro image display device that utilized MEMS-based waveguide to replace the optical fiber, which can potentially overcome the size limitations of mirror-based display. In this research, an improved waveguide scanner system using a fully integrated MEMS-based push-pull actuator is presented. This prototype features monolithic integration of the waveguide, actuator, and light source, and removes the dependence on external actuators used by the previous design. The transmission efficiency is low and cantilever is slightly under tensile stress due to inherent imperfection in the process imperfection and tooling in fabrication. Nevertheless, 2D light scanning pattern is successfully demonstrated using 1D push-pull actuation.","abstract_has_math":false,"creators":["Gu, Kebin"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Wang, Wei-Chih"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-29","date_published":"2015-09-29","updated_at":"2026-11-19T10:18:31Z","subjects":["fiber optic resonant scanner; MEMS; micro image display; miniature scanner technology; push-pull actuator; SU-8","Mechanical engineering"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/34052","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/34052","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F34052","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wang, Wei-Chih"]},{"key":"dc:creator","label":"Author","values":["Gu, Kebin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-29T21:25:28Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-09-29"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2017-09-18T21:25:28Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2015"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fiber optic resonant scanner; MEMS; micro image display; miniature scanner technology; push-pull actuator; SU-8"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Gu_washington_0250E_15175.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/34052"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--University of Washington, 2015"]},{"key":"dc:description.abstract","label":"Abstract","values":["In recent years, miniature scanner technologies, including micro-electro-mechanical system (MEMS) scanners, have started to appear on the market. Most miniature scanner technologies utilize MEMS scanner mirrors. However, this approach has many limitations. In the meanwhile, a competing technology called fiber optic resonant scanner (FORS) has also been developed in order to obtain forward image. An off-the-shelf piezoelectric actuator at the base to create transverse vibrations of a resonating optical fiber has shown to be an effective method for generating 1D and 2D laser line scans. We previously developed a 2D micro image display device that utilized MEMS-based waveguide to replace the optical fiber, which can potentially overcome the size limitations of mirror-based display. In this research, an improved waveguide scanner system using a fully integrated MEMS-based push-pull actuator is presented. This prototype features monolithic integration of the waveguide, actuator, and light source, and removes the dependence on external actuators used by the previous design. The transmission efficiency is low and cantilever is slightly under tensile stress due to inherent imperfection in the process imperfection and tooling in fabrication. Nevertheless, 2D light scanning pattern is successfully demonstrated using 1D push-pull actuation."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Restrict to UW for 2 years -- then make Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of a 2D Mechanical Resonant Push-Pull Scanning Endoscope"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wang, Wei-Chih"],"dc:creator":["Gu, Kebin"],"dc:date.accessioned":["2015-09-29T21:25:28Z"],"dc:date.issued":["2015-09-29"],"dc:date.liftdate":["2017-09-18T21:25:28Z"],"dc:date.submitted":["2015"],"dc:description":["Thesis (Ph.D.)--University of Washington, 2015"],"dc:description.abstract":["In recent years, miniature scanner technologies, including micro-electro-mechanical system (MEMS) scanners, have started to appear on the market. Most miniature scanner technologies utilize MEMS scanner mirrors. However, this approach has many limitations. In the meanwhile, a competing technology called fiber optic resonant scanner (FORS) has also been developed in order to obtain forward image. An off-the-shelf piezoelectric actuator at the base to create transverse vibrations of a resonating optical fiber has shown to be an effective method for generating 1D and 2D laser line scans. We previously developed a 2D micro image display device that utilized MEMS-based waveguide to replace the optical fiber, which can potentially overcome the size limitations of mirror-based display. In this research, an improved waveguide scanner system using a fully integrated MEMS-based push-pull actuator is presented. This prototype features monolithic integration of the waveguide, actuator, and light source, and removes the dependence on external actuators used by the previous design. The transmission efficiency is low and cantilever is slightly under tensile stress due to inherent imperfection in the process imperfection and tooling in fabrication. Nevertheless, 2D light scanning pattern is successfully demonstrated using 1D push-pull actuation."],"dc:embargo.terms":["Restrict to UW for 2 years -- then make Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Gu_washington_0250E_15175.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/34052"],"dc:language.iso":["en_US"],"dc:rights":["Copyright is held by the individual authors."],"dc:subject":["fiber optic resonant scanner; MEMS; micro image display; miniature scanner technology; push-pull actuator; SU-8"],"dc:subject.other":["Mechanical engineering"],"dc:title":["Development of a 2D Mechanical Resonant Push-Pull Scanning Endoscope"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:18:31Z"}