{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/35161"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/35161","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Analytical Methods for the Detection and Quantification of Trenbolone Acetate Metabolites, Altrenogest and Related Photoproducts via Liquid Chromatography Tandem Mass Spectrometry","abstract":"Photoreaction coupled with liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) was used to develop an analytical method for the detection and quantification of trenbolone metabolites, altrenogest, and related photoproducts in water. Target parent analytes were 17α-trenbolone (17α-TBOH), 17β-trenbolone (17β-TBOH), trendione (TBO), and altrenogest (ALT); target photoproducts were the metastable 5-hydroxy- and 12-hydroxy- photoproducts of 17α/17β-TBOH and TBO, and the cyclo-addition and hydroxy-cyclo-addition photoproducts of altrenogest. Photoproducts were generated with a solar simulator reacting trenbolone metabolite (or altrenogest) samples for 6 hrs (>10 half lives). Samples were extracted with C18 solid phase extraction (SPE) cartridges before liquid chromatographic separation with a reverse-phase C18 column with water and methanol mobile phases and ESI+ MS detection. Method detection limits (MDL's) and quantification limits (MQL's) for all compounds were near or below 1 ng L-1 except for 17β-TBOH photoproducts, which had MDL's <2 ng L-1 and MQL's <4 ng L-1. Matrix suppression was <30% using lake water, and SPE recovery rates were near/above 100%, except for 17β-TBOH photoproducts, with recoveries >75%. Intra-day relative standard deviations (RSD's) were <30% for TBO and its products, <20% for all others.","abstract_html":"Photoreaction coupled with liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) was used to develop an analytical method for the detection and quantification of trenbolone metabolites, altrenogest, and related photoproducts in water. Target parent analytes were 17α-trenbolone (17α-TBOH), 17β-trenbolone (17β-TBOH), trendione (TBO), and altrenogest (ALT); target photoproducts were the metastable 5-hydroxy- and 12-hydroxy- photoproducts of 17α/17β-TBOH and TBO, and the cyclo-addition and hydroxy-cyclo-addition photoproducts of altrenogest. Photoproducts were generated with a solar simulator reacting trenbolone metabolite (or altrenogest) samples for 6 hrs (&gt;10 half lives). Samples were extracted with C18 solid phase extraction (SPE) cartridges before liquid chromatographic separation with a reverse-phase C18 column with water and methanol mobile phases and ESI+ MS detection. Method detection limits (MDL&#x27;s) and quantification limits (MQL&#x27;s) for all compounds were near or below 1 ng L-1 except for 17β-TBOH photoproducts, which had MDL&#x27;s &lt;2 ng L-1 and MQL&#x27;s &lt;4 ng L-1. Matrix suppression was &lt;30% using lake water, and SPE recovery rates were near/above 100%, except for 17β-TBOH photoproducts, with recoveries &gt;75%. Intra-day relative standard deviations (RSD&#x27;s) were &lt;30% for TBO and its products, &lt;20% for all others.","abstract_has_math":false,"creators":["Kenyon, Philip"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Kolodziej, Edward P"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-03-11","date_published":"2016-03-11","updated_at":"2026-11-18T20:10:15Z","subjects":["Altrenogest; Liquid Chromatography; Mass Spectrometry; Photohydration; Trenbolone","Analytical chemistry","civil engineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/35161","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/35161","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F35161","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kolodziej, Edward P"]},{"key":"dc:creator","label":"Author","values":["Kenyon, Philip"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-03-11T22:38:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-03-11T22:38:40Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-03-11"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2015-12"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Altrenogest; Liquid Chromatography; Mass Spectrometry; Photohydration; Trenbolone"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Analytical chemistry","civil engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Kenyon_washington_0250O_15355.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/35161"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2015-12"]},{"key":"dc:description.abstract","label":"Abstract","values":["Photoreaction coupled with liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) was used to develop an analytical method for the detection and quantification of trenbolone metabolites, altrenogest, and related photoproducts in water. Target parent analytes were 17α-trenbolone (17α-TBOH), 17β-trenbolone (17β-TBOH), trendione (TBO), and altrenogest (ALT); target photoproducts were the metastable 5-hydroxy- and 12-hydroxy- photoproducts of 17α/17β-TBOH and TBO, and the cyclo-addition and hydroxy-cyclo-addition photoproducts of altrenogest. Photoproducts were generated with a solar simulator reacting trenbolone metabolite (or altrenogest) samples for 6 hrs (>10 half lives). Samples were extracted with C18 solid phase extraction (SPE) cartridges before liquid chromatographic separation with a reverse-phase C18 column with water and methanol mobile phases and ESI+ MS detection. Method detection limits (MDL's) and quantification limits (MQL's) for all compounds were near or below 1 ng L-1 except for 17β-TBOH photoproducts, which had MDL's <2 ng L-1 and MQL's <4 ng L-1. Matrix suppression was <30% using lake water, and SPE recovery rates were near/above 100%, except for 17β-TBOH photoproducts, with recoveries >75%. Intra-day relative standard deviations (RSD's) were <30% for TBO and its products, <20% for all others."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Analytical Methods for the Detection and Quantification of Trenbolone Acetate Metabolites, Altrenogest and Related Photoproducts via Liquid Chromatography Tandem Mass Spectrometry"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kolodziej, Edward P"],"dc:creator":["Kenyon, Philip"],"dc:date.accessioned":["2016-03-11T22:38:40Z"],"dc:date.available":["2016-03-11T22:38:40Z"],"dc:date.issued":["2016-03-11"],"dc:date.submitted":["2015-12"],"dc:description":["Thesis (Master's)--University of Washington, 2015-12"],"dc:description.abstract":["Photoreaction coupled with liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) was used to develop an analytical method for the detection and quantification of trenbolone metabolites, altrenogest, and related photoproducts in water. Target parent analytes were 17α-trenbolone (17α-TBOH), 17β-trenbolone (17β-TBOH), trendione (TBO), and altrenogest (ALT); target photoproducts were the metastable 5-hydroxy- and 12-hydroxy- photoproducts of 17α/17β-TBOH and TBO, and the cyclo-addition and hydroxy-cyclo-addition photoproducts of altrenogest. Photoproducts were generated with a solar simulator reacting trenbolone metabolite (or altrenogest) samples for 6 hrs (>10 half lives). Samples were extracted with C18 solid phase extraction (SPE) cartridges before liquid chromatographic separation with a reverse-phase C18 column with water and methanol mobile phases and ESI+ MS detection. Method detection limits (MDL's) and quantification limits (MQL's) for all compounds were near or below 1 ng L-1 except for 17β-TBOH photoproducts, which had MDL's <2 ng L-1 and MQL's <4 ng L-1. Matrix suppression was <30% using lake water, and SPE recovery rates were near/above 100%, except for 17β-TBOH photoproducts, with recoveries >75%. Intra-day relative standard deviations (RSD's) were <30% for TBO and its products, <20% for all others."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Kenyon_washington_0250O_15355.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/35161"],"dc:language.iso":["en_US"],"dc:subject":["Altrenogest; Liquid Chromatography; Mass Spectrometry; Photohydration; Trenbolone"],"dc:subject.other":["Analytical chemistry","civil engineering"],"dc:title":["Analytical Methods for the Detection and Quantification of Trenbolone Acetate Metabolites, Altrenogest and Related Photoproducts via Liquid Chromatography Tandem Mass Spectrometry"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:10:15Z"}