{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/36759"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/36759","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Facilitating Locking Pin Alignment in Transtibial Amputees via Auto-Retracting Tethered Pin","abstract":"Transtibial amputees have a variety of suspension systems available to them. One of the more common systems uses a locking pin to create a mechanical connection to their prosthesis. For those using a locking pin, it is common for the user to partially doff while seated in order to release pressures created by the socket on the residual limb. When attempting to re-don, there can be difficulty aligning and inserting the pin into the lock, requiring multiple attempts or for the user to stand with a not yet connected prosthesis. This can be an issue and possibly a fall risk for a new user or someone who has poor proprioception. By introducing an auto-retracting tether between the socket and pin, a constant connection is created. The retraction guides the pin into the lock without fail and allows for ease of donning while seated. In this investigation, a prototype design is modelled and built. Transtibial amputee participants are fitted with the system and provide feedback to further develop the system. Feedback was overall positive with a majority saying they would personally use the system. This improved functionality is designed to promote the frequency of partial doffing which may positively impact limb health.","abstract_html":"Transtibial amputees have a variety of suspension systems available to them. One of the more common systems uses a locking pin to create a mechanical connection to their prosthesis. For those using a locking pin, it is common for the user to partially doff while seated in order to release pressures created by the socket on the residual limb. When attempting to re-don, there can be difficulty aligning and inserting the pin into the lock, requiring multiple attempts or for the user to stand with a not yet connected prosthesis. This can be an issue and possibly a fall risk for a new user or someone who has poor proprioception. By introducing an auto-retracting tether between the socket and pin, a constant connection is created. The retraction guides the pin into the lock without fail and allows for ease of donning while seated. In this investigation, a prototype design is modelled and built. Transtibial amputee participants are fitted with the system and provide feedback to further develop the system. Feedback was overall positive with a majority saying they would personally use the system. This improved functionality is designed to promote the frequency of partial doffing which may positively impact limb health.","abstract_has_math":false,"creators":["Goldstein, Mark"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Sanders, Joan"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-07-14","date_published":"2016-07-14","updated_at":"2026-11-18T20:02:31Z","subjects":["Mechanical engineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/36759","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/36759","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F36759","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sanders, Joan"]},{"key":"dc:creator","label":"Author","values":["Goldstein, Mark"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-07-14T16:43:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-07-14T16:43:26Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-07-14"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Goldstein_washington_0250O_15961.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/36759"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2016-06"]},{"key":"dc:description.abstract","label":"Abstract","values":["Transtibial amputees have a variety of suspension systems available to them. One of the more common systems uses a locking pin to create a mechanical connection to their prosthesis. For those using a locking pin, it is common for the user to partially doff while seated in order to release pressures created by the socket on the residual limb. When attempting to re-don, there can be difficulty aligning and inserting the pin into the lock, requiring multiple attempts or for the user to stand with a not yet connected prosthesis. This can be an issue and possibly a fall risk for a new user or someone who has poor proprioception. By introducing an auto-retracting tether between the socket and pin, a constant connection is created. The retraction guides the pin into the lock without fail and allows for ease of donning while seated. In this investigation, a prototype design is modelled and built. Transtibial amputee participants are fitted with the system and provide feedback to further develop the system. Feedback was overall positive with a majority saying they would personally use the system. This improved functionality is designed to promote the frequency of partial doffing which may positively impact limb health."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Facilitating Locking Pin Alignment in Transtibial Amputees via Auto-Retracting Tethered Pin"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sanders, Joan"],"dc:creator":["Goldstein, Mark"],"dc:date.accessioned":["2016-07-14T16:43:26Z"],"dc:date.available":["2016-07-14T16:43:26Z"],"dc:date.issued":["2016-07-14"],"dc:date.submitted":["2016-06"],"dc:description":["Thesis (Master's)--University of Washington, 2016-06"],"dc:description.abstract":["Transtibial amputees have a variety of suspension systems available to them. One of the more common systems uses a locking pin to create a mechanical connection to their prosthesis. For those using a locking pin, it is common for the user to partially doff while seated in order to release pressures created by the socket on the residual limb. When attempting to re-don, there can be difficulty aligning and inserting the pin into the lock, requiring multiple attempts or for the user to stand with a not yet connected prosthesis. This can be an issue and possibly a fall risk for a new user or someone who has poor proprioception. By introducing an auto-retracting tether between the socket and pin, a constant connection is created. The retraction guides the pin into the lock without fail and allows for ease of donning while seated. In this investigation, a prototype design is modelled and built. Transtibial amputee participants are fitted with the system and provide feedback to further develop the system. Feedback was overall positive with a majority saying they would personally use the system. This improved functionality is designed to promote the frequency of partial doffing which may positively impact limb health."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Goldstein_washington_0250O_15961.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/36759"],"dc:language.iso":["en_US"],"dc:subject.other":["Mechanical engineering"],"dc:title":["Facilitating Locking Pin Alignment in Transtibial Amputees via Auto-Retracting Tethered Pin"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:02:31Z"}