{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/37189"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/37189","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Hindfoot Kinematics of Healthy Subjects Using Lateral Wedge Insoles in a Biplane Fluoroscopy System","abstract":"Lateral wedge insoles (LWIs) are a type of orthosis used to reduce the external knee adduction moment (EKAM), which is associated with the development and progression of tibiofemoral osteoarthritis. However, their effect on kinematics at the hindfoot is unclear. Biplane fluoroscopy was utilized to measure the kinematics of the tibia, talus, and calcaneus, for a pilot study to demonstrate the feasibility of data collection and analysis. To motivate the study, a literature review of LWIs was first performed, including discussion of EKAM, hindfoot moment, dose response, pain scores and more. A LabVIEW Real-Time system was implemented to upgrade the biplane system to add stance phase timing and additional features. Three subjects were studied in the biplane system with four insole conditions. The calcaneus tended to dorsiflex and invert as stance phase progressed. This study demonstrated that the protocol and data analysis are viable and more subjects can be analyzed.","abstract_html":"Lateral wedge insoles (LWIs) are a type of orthosis used to reduce the external knee adduction moment (EKAM), which is associated with the development and progression of tibiofemoral osteoarthritis. However, their effect on kinematics at the hindfoot is unclear. Biplane fluoroscopy was utilized to measure the kinematics of the tibia, talus, and calcaneus, for a pilot study to demonstrate the feasibility of data collection and analysis. To motivate the study, a literature review of LWIs was first performed, including discussion of EKAM, hindfoot moment, dose response, pain scores and more. A LabVIEW Real-Time system was implemented to upgrade the biplane system to add stance phase timing and additional features. Three subjects were studied in the biplane system with four insole conditions. The calcaneus tended to dorsiflex and invert as stance phase progressed. This study demonstrated that the protocol and data analysis are viable and more subjects can be analyzed.","abstract_has_math":false,"creators":["Pepin, Nathan Richard"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Ledoux, William"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-09-22","date_published":"2016-09-22","updated_at":"2026-11-19T10:18:48Z","subjects":["Biomechanics","EKAM","Fluoroscopy","Gait","Orthosis","Mechanical engineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/37189","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/37189","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F37189","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ledoux, William"]},{"key":"dc:creator","label":"Author","values":["Pepin, Nathan Richard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-09-22T15:47:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-09-22"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2017-09-22T15:47:56Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomechanics","EKAM","Fluoroscopy","Gait","Orthosis"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Pepin_washington_0250O_16520.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/37189"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2016-08"]},{"key":"dc:description.abstract","label":"Abstract","values":["Lateral wedge insoles (LWIs) are a type of orthosis used to reduce the external knee adduction moment (EKAM), which is associated with the development and progression of tibiofemoral osteoarthritis. However, their effect on kinematics at the hindfoot is unclear. Biplane fluoroscopy was utilized to measure the kinematics of the tibia, talus, and calcaneus, for a pilot study to demonstrate the feasibility of data collection and analysis. To motivate the study, a literature review of LWIs was first performed, including discussion of EKAM, hindfoot moment, dose response, pain scores and more. A LabVIEW Real-Time system was implemented to upgrade the biplane system to add stance phase timing and additional features. Three subjects were studied in the biplane system with four insole conditions. The calcaneus tended to dorsiflex and invert as stance phase progressed. This study demonstrated that the protocol and data analysis are viable and more subjects can be analyzed."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Restrict to UW for 1 year -- then make Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Hindfoot Kinematics of Healthy Subjects Using Lateral Wedge Insoles in a Biplane Fluoroscopy System"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ledoux, William"],"dc:creator":["Pepin, Nathan Richard"],"dc:date.accessioned":["2016-09-22T15:47:56Z"],"dc:date.issued":["2016-09-22"],"dc:date.liftdate":["2017-09-22T15:47:56Z"],"dc:date.submitted":["2016-08"],"dc:description":["Thesis (Master's)--University of Washington, 2016-08"],"dc:description.abstract":["Lateral wedge insoles (LWIs) are a type of orthosis used to reduce the external knee adduction moment (EKAM), which is associated with the development and progression of tibiofemoral osteoarthritis. However, their effect on kinematics at the hindfoot is unclear. Biplane fluoroscopy was utilized to measure the kinematics of the tibia, talus, and calcaneus, for a pilot study to demonstrate the feasibility of data collection and analysis. To motivate the study, a literature review of LWIs was first performed, including discussion of EKAM, hindfoot moment, dose response, pain scores and more. A LabVIEW Real-Time system was implemented to upgrade the biplane system to add stance phase timing and additional features. Three subjects were studied in the biplane system with four insole conditions. The calcaneus tended to dorsiflex and invert as stance phase progressed. This study demonstrated that the protocol and data analysis are viable and more subjects can be analyzed."],"dc:embargo.terms":["Restrict to UW for 1 year -- then make Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Pepin_washington_0250O_16520.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/37189"],"dc:language.iso":["en_US"],"dc:subject":["Biomechanics","EKAM","Fluoroscopy","Gait","Orthosis"],"dc:subject.other":["Mechanical engineering"],"dc:title":["Hindfoot Kinematics of Healthy Subjects Using Lateral Wedge Insoles in a Biplane Fluoroscopy System"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:18:48Z"}