{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/38613"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/38613","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Integrated Circuit and System Design for Wireless Biosignal Monitoring","abstract":"This document presents various techniques and systems for recording biological signals. Specifically electrocardiography (ECG), electromyography (EMG) and single-unit neuron recording applications are discussed. These recording techniques sense electrical potentials generated by biological functions which are then amplified and sampled using electronic devices. The evolution of this biosignal monitor electronic device over four design genera- tions highlights the advantages of utilizing integrated circuits (ICs) designed solely for the given application. The final design combines the benefits of a low power IC and the highly customizable nature of a microconroller. Thanks to its high level of customizability after fabrication this system is ideal for innumerable applications in the field of biosignal moni- toring by lowering the technically barrier and development time required for many future biosignal monitoring applications.","abstract_html":"This document presents various techniques and systems for recording biological signals. Specifically electrocardiography (ECG), electromyography (EMG) and single-unit neuron recording applications are discussed. These recording techniques sense electrical potentials generated by biological functions which are then amplified and sampled using electronic devices. The evolution of this biosignal monitor electronic device over four design genera- tions highlights the advantages of utilizing integrated circuits (ICs) designed solely for the given application. The final design combines the benefits of a low power IC and the highly customizable nature of a microconroller. Thanks to its high level of customizability after fabrication this system is ideal for innumerable applications in the field of biosignal moni- toring by lowering the technically barrier and development time required for many future biosignal monitoring applications.","abstract_has_math":false,"creators":["Morrison, Timothy David"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Otis, Brian P"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-18T20:06:07Z","subjects":["Electrical engineering"],"languages":["en_US"],"rights":["none"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/38613","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/38613","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F38613","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Otis, Brian P"]},{"key":"dc:creator","label":"Author","values":["Morrison, Timothy David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-05-16T22:12:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-05-16T22:12:39Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2017-03"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical engineering"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Electrical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["none"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Morrison_washington_0250E_16860.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/38613"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--University of Washington, 2017-03"]},{"key":"dc:description.abstract","label":"Abstract","values":["This document presents various techniques and systems for recording biological signals. Specifically electrocardiography (ECG), electromyography (EMG) and single-unit neuron recording applications are discussed. These recording techniques sense electrical potentials generated by biological functions which are then amplified and sampled using electronic devices. The evolution of this biosignal monitor electronic device over four design genera- tions highlights the advantages of utilizing integrated circuits (ICs) designed solely for the given application. The final design combines the benefits of a low power IC and the highly customizable nature of a microconroller. Thanks to its high level of customizability after fabrication this system is ideal for innumerable applications in the field of biosignal moni- toring by lowering the technically barrier and development time required for many future biosignal monitoring applications."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Integrated Circuit and System Design for Wireless Biosignal Monitoring"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Otis, Brian P"],"dc:creator":["Morrison, Timothy David"],"dc:date.accessioned":["2017-05-16T22:12:39Z"],"dc:date.available":["2017-05-16T22:12:39Z"],"dc:date.submitted":["2017-03"],"dc:description":["Thesis (Ph.D.)--University of Washington, 2017-03"],"dc:description.abstract":["This document presents various techniques and systems for recording biological signals. Specifically electrocardiography (ECG), electromyography (EMG) and single-unit neuron recording applications are discussed. These recording techniques sense electrical potentials generated by biological functions which are then amplified and sampled using electronic devices. The evolution of this biosignal monitor electronic device over four design genera- tions highlights the advantages of utilizing integrated circuits (ICs) designed solely for the given application. The final design combines the benefits of a low power IC and the highly customizable nature of a microconroller. Thanks to its high level of customizability after fabrication this system is ideal for innumerable applications in the field of biosignal moni- toring by lowering the technically barrier and development time required for many future biosignal monitoring applications."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Morrison_washington_0250E_16860.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/38613"],"dc:language.iso":["en_US"],"dc:rights":["none"],"dc:subject":["Electrical engineering"],"dc:subject.other":["Electrical engineering"],"dc:title":["Integrated Circuit and System Design for Wireless Biosignal Monitoring"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:06:07Z"}