{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/40244"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/40244","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Individually-controllable magnetic artificial cilia for microfluidic manipulation tasks","abstract":"This thesis presents the design, modeling, and control of a magnetic artificial cilia system in which the cilia are individually controllable. In nature, cilia exhibit metachronal waves, or a phase difference between adjacent cilia that results in a traveling wave, which may improve pumping performance or efficiency of biological cilia. However, existing magnetic artificial cilia devices typically use actuation by a rotating field generated by Helmholtz coils or by a rotating permanent magnet. These field sources cannot apply a phase shift to the cilia array and therefore cannot generate a metachronal wave. Nevertheless, magnetic actuation remains desirable for cilia devices as it allows for biocompatibility, precise control of sys- tem inputs, and low-cost fabrication of the cilia. In this thesis, a new design for magnetic artificial cilia is presented in which the actuating magnetic field is localized, enabling indi- vidual actuation. However, this design decision leads to challenging research problems in input-pattern identification, nonlinear systems modeling, and control. In addressing these challenges, the contributions of this thesis are to (i) demonstrate that individual control can improve performance in cilia-based devices, (ii) present accurate nonlinear models for pre- dicting the static response, and (iii) develop a machine-learning-based system identification and control strategy for output tracking.","abstract_html":"This thesis presents the design, modeling, and control of a magnetic artificial cilia system in which the cilia are individually controllable. In nature, cilia exhibit metachronal waves, or a phase difference between adjacent cilia that results in a traveling wave, which may improve pumping performance or efficiency of biological cilia. However, existing magnetic artificial cilia devices typically use actuation by a rotating field generated by Helmholtz coils or by a rotating permanent magnet. These field sources cannot apply a phase shift to the cilia array and therefore cannot generate a metachronal wave. Nevertheless, magnetic actuation remains desirable for cilia devices as it allows for biocompatibility, precise control of sys- tem inputs, and low-cost fabrication of the cilia. In this thesis, a new design for magnetic artificial cilia is presented in which the actuating magnetic field is localized, enabling indi- vidual actuation. However, this design decision leads to challenging research problems in input-pattern identification, nonlinear systems modeling, and control. In addressing these challenges, the contributions of this thesis are to (i) demonstrate that individual control can improve performance in cilia-based devices, (ii) present accurate nonlinear models for pre- dicting the static response, and (iii) develop a machine-learning-based system identification and control strategy for output tracking.","abstract_has_math":false,"creators":["Banka, Nathan"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Devasia, Santosh"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-08-11","date_published":"2017-08-11","updated_at":"2026-11-18T20:03:33Z","subjects":["Mechanical engineering"],"languages":["en_US"],"rights":["none"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/40244","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/40244","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F40244","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Devasia, Santosh"]},{"key":"dc:creator","label":"Author","values":["Banka, Nathan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-08-11T22:57:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-08-11T22:57:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-08-11"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2017-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical engineering"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["none"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Banka_washington_0250E_17319.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/40244"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--University of Washington, 2017-06"]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the design, modeling, and control of a magnetic artificial cilia system in which the cilia are individually controllable. In nature, cilia exhibit metachronal waves, or a phase difference between adjacent cilia that results in a traveling wave, which may improve pumping performance or efficiency of biological cilia. However, existing magnetic artificial cilia devices typically use actuation by a rotating field generated by Helmholtz coils or by a rotating permanent magnet. These field sources cannot apply a phase shift to the cilia array and therefore cannot generate a metachronal wave. Nevertheless, magnetic actuation remains desirable for cilia devices as it allows for biocompatibility, precise control of sys- tem inputs, and low-cost fabrication of the cilia. In this thesis, a new design for magnetic artificial cilia is presented in which the actuating magnetic field is localized, enabling indi- vidual actuation. However, this design decision leads to challenging research problems in input-pattern identification, nonlinear systems modeling, and control. In addressing these challenges, the contributions of this thesis are to (i) demonstrate that individual control can improve performance in cilia-based devices, (ii) present accurate nonlinear models for pre- dicting the static response, and (iii) develop a machine-learning-based system identification and control strategy for output tracking."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Individually-controllable magnetic artificial cilia for microfluidic manipulation tasks"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Devasia, Santosh"],"dc:creator":["Banka, Nathan"],"dc:date.accessioned":["2017-08-11T22:57:45Z"],"dc:date.available":["2017-08-11T22:57:45Z"],"dc:date.issued":["2017-08-11"],"dc:date.submitted":["2017-06"],"dc:description":["Thesis (Ph.D.)--University of Washington, 2017-06"],"dc:description.abstract":["This thesis presents the design, modeling, and control of a magnetic artificial cilia system in which the cilia are individually controllable. In nature, cilia exhibit metachronal waves, or a phase difference between adjacent cilia that results in a traveling wave, which may improve pumping performance or efficiency of biological cilia. However, existing magnetic artificial cilia devices typically use actuation by a rotating field generated by Helmholtz coils or by a rotating permanent magnet. These field sources cannot apply a phase shift to the cilia array and therefore cannot generate a metachronal wave. Nevertheless, magnetic actuation remains desirable for cilia devices as it allows for biocompatibility, precise control of sys- tem inputs, and low-cost fabrication of the cilia. In this thesis, a new design for magnetic artificial cilia is presented in which the actuating magnetic field is localized, enabling indi- vidual actuation. However, this design decision leads to challenging research problems in input-pattern identification, nonlinear systems modeling, and control. In addressing these challenges, the contributions of this thesis are to (i) demonstrate that individual control can improve performance in cilia-based devices, (ii) present accurate nonlinear models for pre- dicting the static response, and (iii) develop a machine-learning-based system identification and control strategy for output tracking."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Banka_washington_0250E_17319.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/40244"],"dc:language.iso":["en_US"],"dc:rights":["none"],"dc:subject":["Mechanical engineering"],"dc:subject.other":["Mechanical engineering"],"dc:title":["Individually-controllable magnetic artificial cilia for microfluidic manipulation tasks"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:03:33Z"}