{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/42960"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/42960","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Development of a Highly Sensitive Protein Diagnostic Device using Isothermal Strand Displacement Amplification","abstract":"The lateral flow test (LFT) is the preferred tool for detection of protein biomarkers in low-resource settings. While low-cost and rapid, these immunoassay devices often suffer from limited sensitivity in the single chemical step format. Our group has addressed this deficiency by coupling a lateral flow test to isothermal strand displacement amplification (iSDA), a nucleic-acid amplification test (NAAT). This novel method is called LFT-iSDA and uses an oligonucleotide-labelled detection antibody in the immunoassay as the target template for iSDA. In its current embodiment, LFT-iSDA is ~10,000x more sensitive than gold nanoparticle-based LFTs, but is highly manual and relies on laboratory infrastructure. Here we present preliminary development of a diagnostic device integrating the highly sensitive LFT-iSDA into a cartridge supporting rapid time-to-results and minimal user-steps— a format amenable to decentralized test settings. We characterized performance limitations of this assay, developed a real-time fluorescence detection system, and used a two-dimensional paper network (2DPN) to semi-automate this multi-step chemical process. These results show important progress toward enabling highly sensitive protein detection in a user-friendly, low-cost device, at the point of care.","abstract_html":"The lateral flow test (LFT) is the preferred tool for detection of protein biomarkers in low-resource settings. While low-cost and rapid, these immunoassay devices often suffer from limited sensitivity in the single chemical step format. Our group has addressed this deficiency by coupling a lateral flow test to isothermal strand displacement amplification (iSDA), a nucleic-acid amplification test (NAAT). This novel method is called LFT-iSDA and uses an oligonucleotide-labelled detection antibody in the immunoassay as the target template for iSDA. In its current embodiment, LFT-iSDA is ~10,000x more sensitive than gold nanoparticle-based LFTs, but is highly manual and relies on laboratory infrastructure. Here we present preliminary development of a diagnostic device integrating the highly sensitive LFT-iSDA into a cartridge supporting rapid time-to-results and minimal user-steps— a format amenable to decentralized test settings. We characterized performance limitations of this assay, developed a real-time fluorescence detection system, and used a two-dimensional paper network (2DPN) to semi-automate this multi-step chemical process. These results show important progress toward enabling highly sensitive protein detection in a user-friendly, low-cost device, at the point of care.","abstract_has_math":false,"creators":["Guelig, Dylan"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Yager, Paul"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-11-28","date_published":"2018-11-28","updated_at":"2026-11-18T20:08:27Z","subjects":["Fluorescence Detection","Immuno-NAAT","Lateral flow test","Biomedical engineering","Bioengineering"],"languages":["en_US"],"rights":["none"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Guelig_washington_0250O_19137.pdf"],"render_values":[{"text":"Guelig_washington_0250O_19137.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1773/42960","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1773/42960","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Awashington%3Aoai%3Adigital.lib.washington.edu%3A1773%2F42960","prefix":"oai_dc"},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F42960","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yager, Paul"]},{"key":"dc:creator","label":"Author","values":["Guelig, Dylan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-11-28T03:15:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-11-28T03:15:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-11-28"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2018"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fluorescence Detection","Immuno-NAAT","Lateral flow test","Biomedical engineering"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["none"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Guelig_washington_0250O_19137.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/42960"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2018"]},{"key":"dc:description.abstract","label":"Abstract","values":["The lateral flow test (LFT) is the preferred tool for detection of protein biomarkers in low-resource settings. While low-cost and rapid, these immunoassay devices often suffer from limited sensitivity in the single chemical step format. Our group has addressed this deficiency by coupling a lateral flow test to isothermal strand displacement amplification (iSDA), a nucleic-acid amplification test (NAAT). This novel method is called LFT-iSDA and uses an oligonucleotide-labelled detection antibody in the immunoassay as the target template for iSDA. In its current embodiment, LFT-iSDA is ~10,000x more sensitive than gold nanoparticle-based LFTs, but is highly manual and relies on laboratory infrastructure. Here we present preliminary development of a diagnostic device integrating the highly sensitive LFT-iSDA into a cartridge supporting rapid time-to-results and minimal user-steps— a format amenable to decentralized test settings. We characterized performance limitations of this assay, developed a real-time fluorescence detection system, and used a two-dimensional paper network (2DPN) to semi-automate this multi-step chemical process. These results show important progress toward enabling highly sensitive protein detection in a user-friendly, low-cost device, at the point of care."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of a Highly Sensitive Protein Diagnostic Device using Isothermal Strand Displacement Amplification"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yager, Paul"],"dc:creator":["Guelig, Dylan"],"dc:date.accessioned":["2018-11-28T03:15:13Z"],"dc:date.available":["2018-11-28T03:15:13Z"],"dc:date.issued":["2018-11-28"],"dc:date.submitted":["2018"],"dc:description":["Thesis (Master's)--University of Washington, 2018"],"dc:description.abstract":["The lateral flow test (LFT) is the preferred tool for detection of protein biomarkers in low-resource settings. While low-cost and rapid, these immunoassay devices often suffer from limited sensitivity in the single chemical step format. Our group has addressed this deficiency by coupling a lateral flow test to isothermal strand displacement amplification (iSDA), a nucleic-acid amplification test (NAAT). This novel method is called LFT-iSDA and uses an oligonucleotide-labelled detection antibody in the immunoassay as the target template for iSDA. In its current embodiment, LFT-iSDA is ~10,000x more sensitive than gold nanoparticle-based LFTs, but is highly manual and relies on laboratory infrastructure. Here we present preliminary development of a diagnostic device integrating the highly sensitive LFT-iSDA into a cartridge supporting rapid time-to-results and minimal user-steps— a format amenable to decentralized test settings. We characterized performance limitations of this assay, developed a real-time fluorescence detection system, and used a two-dimensional paper network (2DPN) to semi-automate this multi-step chemical process. These results show important progress toward enabling highly sensitive protein detection in a user-friendly, low-cost device, at the point of care."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Guelig_washington_0250O_19137.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/42960"],"dc:language.iso":["en_US"],"dc:rights":["none"],"dc:subject":["Fluorescence Detection","Immuno-NAAT","Lateral flow test","Biomedical engineering"],"dc:subject.other":["Bioengineering"],"dc:title":["Development of a Highly Sensitive Protein Diagnostic Device using Isothermal Strand Displacement Amplification"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:08:27Z"}