{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/42963"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/42963","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Study of Protein-Fluoropolymer Interactions for Passivation of Blood-Contacting Surfaces","abstract":"While decades of biomaterials research have yielded devices that prolong the lives of cardiovascular disease patients, clinicians still rely on dangerous anticoagulants to ensure their anti-thrombogenicity, and thus lack a truly blood compatible biomaterial. Fluoropolymers have offered improvements in this respect, but studies probing protein tight-binding and platelet response have failed to yield correlations between material properties and clinical performance, preventing the optimization of these promising materials. This work presents a fresh approach to addressing this problem, comparing a subset of fluoropolymers with a wide array of properties. Through principal component regression, ESCA, AFM, and contact angle data were compared to adsorption and retention of human albumin and fibrinogen in a competitive binding setting, and preliminary recommendations for certain property-performance relationships were made. The methods developed represent a solid foundation for increasing number of parameters and sample size to enable the rational design of better blood compatible fluoropolymers.","abstract_html":"While decades of biomaterials research have yielded devices that prolong the lives of cardiovascular disease patients, clinicians still rely on dangerous anticoagulants to ensure their anti-thrombogenicity, and thus lack a truly blood compatible biomaterial. Fluoropolymers have offered improvements in this respect, but studies probing protein tight-binding and platelet response have failed to yield correlations between material properties and clinical performance, preventing the optimization of these promising materials. This work presents a fresh approach to addressing this problem, comparing a subset of fluoropolymers with a wide array of properties. Through principal component regression, ESCA, AFM, and contact angle data were compared to adsorption and retention of human albumin and fibrinogen in a competitive binding setting, and preliminary recommendations for certain property-performance relationships were made. The methods developed represent a solid foundation for increasing number of parameters and sample size to enable the rational design of better blood compatible fluoropolymers.","abstract_has_math":false,"creators":["Sotiri, Irini"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Ratner, Buddy D"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-11-28","date_published":"2018-11-28","updated_at":"2026-11-19T10:19:07Z","subjects":["biocompatibility","biomaterials","blood compatibility","fluoropolymer","medical device","proteins","Biomedical engineering","Materials Science","Bioengineering"],"languages":["en_US"],"rights":["CC BY"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/42963","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/42963","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F42963","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ratner, Buddy D"]},{"key":"dc:creator","label":"Author","values":["Sotiri, Irini"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-11-28T03:15:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-11-28"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2019-11-28T03:15:15Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2018"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["biocompatibility","biomaterials","blood compatibility","fluoropolymer","medical device","proteins","Biomedical engineering","Materials Science"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["CC BY"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Sotiri_washington_0250O_19309.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/42963"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2018"]},{"key":"dc:description.abstract","label":"Abstract","values":["While decades of biomaterials research have yielded devices that prolong the lives of cardiovascular disease patients, clinicians still rely on dangerous anticoagulants to ensure their anti-thrombogenicity, and thus lack a truly blood compatible biomaterial. Fluoropolymers have offered improvements in this respect, but studies probing protein tight-binding and platelet response have failed to yield correlations between material properties and clinical performance, preventing the optimization of these promising materials. This work presents a fresh approach to addressing this problem, comparing a subset of fluoropolymers with a wide array of properties. Through principal component regression, ESCA, AFM, and contact angle data were compared to adsorption and retention of human albumin and fibrinogen in a competitive binding setting, and preliminary recommendations for certain property-performance relationships were made. The methods developed represent a solid foundation for increasing number of parameters and sample size to enable the rational design of better blood compatible fluoropolymers."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Restrict to UW for 1 year -- then make Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Study of Protein-Fluoropolymer Interactions for Passivation of Blood-Contacting Surfaces"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ratner, Buddy D"],"dc:creator":["Sotiri, Irini"],"dc:date.accessioned":["2018-11-28T03:15:15Z"],"dc:date.issued":["2018-11-28"],"dc:date.liftdate":["2019-11-28T03:15:15Z"],"dc:date.submitted":["2018"],"dc:description":["Thesis (Master's)--University of Washington, 2018"],"dc:description.abstract":["While decades of biomaterials research have yielded devices that prolong the lives of cardiovascular disease patients, clinicians still rely on dangerous anticoagulants to ensure their anti-thrombogenicity, and thus lack a truly blood compatible biomaterial. Fluoropolymers have offered improvements in this respect, but studies probing protein tight-binding and platelet response have failed to yield correlations between material properties and clinical performance, preventing the optimization of these promising materials. This work presents a fresh approach to addressing this problem, comparing a subset of fluoropolymers with a wide array of properties. Through principal component regression, ESCA, AFM, and contact angle data were compared to adsorption and retention of human albumin and fibrinogen in a competitive binding setting, and preliminary recommendations for certain property-performance relationships were made. The methods developed represent a solid foundation for increasing number of parameters and sample size to enable the rational design of better blood compatible fluoropolymers."],"dc:embargo.terms":["Restrict to UW for 1 year -- then make Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Sotiri_washington_0250O_19309.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/42963"],"dc:language.iso":["en_US"],"dc:rights":["CC BY"],"dc:subject":["biocompatibility","biomaterials","blood compatibility","fluoropolymer","medical device","proteins","Biomedical engineering","Materials Science"],"dc:subject.other":["Bioengineering"],"dc:title":["Study of Protein-Fluoropolymer Interactions for Passivation of Blood-Contacting Surfaces"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:19:07Z"}