{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/43441"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/43441","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Axion-like Dark Matter Detection with Mercury-199 Atoms","abstract":"The objective of this dissertation is to search for axion dark matter through the coupling between the axion field and the electric dipole moment(EDM) of mercury-199 atoms. If the axion is the significant fraction of dark matter, the coupling leads to a time-varying nuclear EDM that oscillates at the frequency proportional to the axion mass, $m_{a}$. We use the data that measures the static EDM of $^{199}Hg$ atoms to look for a simple sinusoidal signal on the top of the static EDM value. The Lomb-Scargle periodogram, as a power spectrum estimator, allows us to analyze our unequally spaced EDM data in time. With two different approaches both with and without error weighting, they give a consistent result on no detection of dark matter. The most significant peak among the four EDM periodograms has a false alarm probability of 31$\\%$ calculated with the Bootstrap method. The magnitude of the maximum peak can be generated by injecting a sinusoidal signal with the amplitude of 1.81$\\times 10^{-29}$ $e \\cdot cm$. The smallest periodic signal our measurement can detect as the maximum peak in the periodogram with 95$\\%$ confidence in the frequency range of 0 to 6.17$\\times 10^{-4}$ Hz is 2.3$\\times 10^{-29}$ $e \\cdot cm$. The static EDM of $^{199}Hg$ by itself is an important topic. This thesis will only briefly mention it and mainly cover the parts that are relevant to time-varying EDM analysis.","abstract_html":"The objective of this dissertation is to search for axion dark matter through the coupling between the axion field and the electric dipole moment(EDM) of mercury-199 atoms. If the axion is the significant fraction of dark matter, the coupling leads to a time-varying nuclear EDM that oscillates at the frequency proportional to the axion mass, <span class=\"etd-inline-math\">m<sub>a</sub></span>. We use the data that measures the static EDM of <span class=\"etd-inline-math\"><sup>199</sup>Hg</span> atoms to look for a simple sinusoidal signal on the top of the static EDM value. The Lomb-Scargle periodogram, as a power spectrum estimator, allows us to analyze our unequally spaced EDM data in time. With two different approaches both with and without error weighting, they give a consistent result on no detection of dark matter. The most significant peak among the four EDM periodograms has a false alarm probability of 31$\\%$ calculated with the Bootstrap method. The magnitude of the maximum peak can be generated by injecting a sinusoidal signal with the amplitude of 1.81<span class=\"etd-inline-math\">\\times 10<sup>-29</sup></span> $e \\cdot cm$. The smallest periodic signal our measurement can detect as the maximum peak in the periodogram with 95$\\%$ confidence in the frequency range of 0 to 6.17<span class=\"etd-inline-math\">\\times 10<sup>-4</sup></span> Hz is 2.3<span class=\"etd-inline-math\">\\times 10<sup>-29</sup></span> $e \\cdot cm$. The static EDM of <span class=\"etd-inline-math\"><sup>199</sup>Hg</span> by itself is an important topic. This thesis will only briefly mention it and mainly cover the parts that are relevant to time-varying EDM analysis.","abstract_has_math":true,"creators":["Chen, Yi"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Heckel, Blayne R"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-02-22","date_published":"2019-02-22","updated_at":"2026-11-18T20:01:28Z","subjects":["Bootstrap","electric dipole moment","periodogram","time-varying EDM","Atomic physics","Physics"],"languages":["en_US"],"rights":["none"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/43441","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/43441","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F43441","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Heckel, Blayne R"]},{"key":"dc:creator","label":"Author","values":["Chen, Yi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-02-22T17:08:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-02-22T17:08:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-02-22"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2018"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bootstrap","electric dipole moment","periodogram","time-varying EDM","Atomic physics"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["none"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Chen_washington_0250E_19508.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/43441"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--University of Washington, 2018"]},{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this dissertation is to search for axion dark matter through the coupling between the axion field and the electric dipole moment(EDM) of mercury-199 atoms. If the axion is the significant fraction of dark matter, the coupling leads to a time-varying nuclear EDM that oscillates at the frequency proportional to the axion mass, $m_{a}$. We use the data that measures the static EDM of $^{199}Hg$ atoms to look for a simple sinusoidal signal on the top of the static EDM value. The Lomb-Scargle periodogram, as a power spectrum estimator, allows us to analyze our unequally spaced EDM data in time. With two different approaches both with and without error weighting, they give a consistent result on no detection of dark matter. The most significant peak among the four EDM periodograms has a false alarm probability of 31$\\%$ calculated with the Bootstrap method. The magnitude of the maximum peak can be generated by injecting a sinusoidal signal with the amplitude of 1.81$\\times 10^{-29}$ $e \\cdot cm$. The smallest periodic signal our measurement can detect as the maximum peak in the periodogram with 95$\\%$ confidence in the frequency range of 0 to 6.17$\\times 10^{-4}$ Hz is 2.3$\\times 10^{-29}$ $e \\cdot cm$. The static EDM of $^{199}Hg$ by itself is an important topic. This thesis will only briefly mention it and mainly cover the parts that are relevant to time-varying EDM analysis."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Axion-like Dark Matter Detection with Mercury-199 Atoms"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Heckel, Blayne R"],"dc:creator":["Chen, Yi"],"dc:date.accessioned":["2019-02-22T17:08:02Z"],"dc:date.available":["2019-02-22T17:08:02Z"],"dc:date.issued":["2019-02-22"],"dc:date.submitted":["2018"],"dc:description":["Thesis (Ph.D.)--University of Washington, 2018"],"dc:description.abstract":["The objective of this dissertation is to search for axion dark matter through the coupling between the axion field and the electric dipole moment(EDM) of mercury-199 atoms. If the axion is the significant fraction of dark matter, the coupling leads to a time-varying nuclear EDM that oscillates at the frequency proportional to the axion mass, $m_{a}$. We use the data that measures the static EDM of $^{199}Hg$ atoms to look for a simple sinusoidal signal on the top of the static EDM value. The Lomb-Scargle periodogram, as a power spectrum estimator, allows us to analyze our unequally spaced EDM data in time. With two different approaches both with and without error weighting, they give a consistent result on no detection of dark matter. The most significant peak among the four EDM periodograms has a false alarm probability of 31$\\%$ calculated with the Bootstrap method. The magnitude of the maximum peak can be generated by injecting a sinusoidal signal with the amplitude of 1.81$\\times 10^{-29}$ $e \\cdot cm$. The smallest periodic signal our measurement can detect as the maximum peak in the periodogram with 95$\\%$ confidence in the frequency range of 0 to 6.17$\\times 10^{-4}$ Hz is 2.3$\\times 10^{-29}$ $e \\cdot cm$. The static EDM of $^{199}Hg$ by itself is an important topic. This thesis will only briefly mention it and mainly cover the parts that are relevant to time-varying EDM analysis."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Chen_washington_0250E_19508.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/43441"],"dc:language.iso":["en_US"],"dc:rights":["none"],"dc:subject":["Bootstrap","electric dipole moment","periodogram","time-varying EDM","Atomic physics"],"dc:subject.other":["Physics"],"dc:title":["Axion-like Dark Matter Detection with Mercury-199 Atoms"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:01:28Z"}