{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/43736"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/43736","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Measuring the Precession Frequency in the E989 Muon g-2 Experiment","abstract":"The E989 Muon $g-2$ Experiment aims to measure the anomalous magnetic moment of the muon, $a_\\mu$, to an unprecedented precision of 140 parts per billion (ppb). There currently stands a greater than 3$\\sigma$ discrepancy between the best measurement of $a_\\mu$ and its theoretical value predicted using the Standard Model. The E989 experiment seeks to either resolve or confirm this discrepancy, which is suggestive of new physics interactions within reach of many contemporary experiments. To achieve the E989 target precision, the anomalous precession frequency, $\\omega_a$, of muons in a magnetic storage ring must be determined with a systematic uncertainty below 70\\,ppb. This frequency is imprinted on the time-dependent energy distribution of decay positrons observed by 24 electromagnetic calorimeters. These calorimeters feature a novel design optimized expressly for the stringent demands of the $\\omega_a$ measurement. This dissertation outlines the motivation for and measurement principles behind E989, discusses the requirements, prototyping, testing, commissioning, and operations of the electromagnetic calorimeters, and presents a preliminary, blinded analysis of data collected in the spring of 2018.","abstract_html":"The E989 Muon $g-2$ Experiment aims to measure the anomalous magnetic moment of the muon, <span class=\"etd-inline-math\">a<sub>\\</sub>mu</span>, to an unprecedented precision of 140 parts per billion (ppb). There currently stands a greater than 3<span class=\"etd-inline-math\">&sigma;</span> discrepancy between the best measurement of <span class=\"etd-inline-math\">a<sub>\\</sub>mu</span> and its theoretical value predicted using the Standard Model. The E989 experiment seeks to either resolve or confirm this discrepancy, which is suggestive of new physics interactions within reach of many contemporary experiments. To achieve the E989 target precision, the anomalous precession frequency, <span class=\"etd-inline-math\">&omega;<sub>a</sub></span>, of muons in a magnetic storage ring must be determined with a systematic uncertainty below 70\\,ppb. This frequency is imprinted on the time-dependent energy distribution of decay positrons observed by 24 electromagnetic calorimeters. These calorimeters feature a novel design optimized expressly for the stringent demands of the <span class=\"etd-inline-math\">&omega;<sub>a</sub></span> measurement. This dissertation outlines the motivation for and measurement principles behind E989, discusses the requirements, prototyping, testing, commissioning, and operations of the electromagnetic calorimeters, and presents a preliminary, blinded analysis of data collected in the spring of 2018.","abstract_has_math":true,"creators":["Fienberg, Aaron"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Hertzog, David W"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-05-02","date_published":"2019-05-02","updated_at":"2026-11-18T20:09:25Z","subjects":["calorimeter","magnetic dipole moment","muon","precision","Physics"],"languages":["en_US"],"rights":["CC BY-NC-SA"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Fienberg_washington_0250E_19639.pdf"],"render_values":[{"text":"Fienberg_washington_0250E_19639.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1773/43736","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1773/43736","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F43736","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hertzog, David W"]},{"key":"dc:creator","label":"Author","values":["Fienberg, Aaron"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-05-02T23:21:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-05-02T23:21:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-05-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2019"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["calorimeter","magnetic dipole moment","muon","precision","Physics"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["CC BY-NC-SA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Fienberg_washington_0250E_19639.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/43736"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--University of Washington, 2019"]},{"key":"dc:description.abstract","label":"Abstract","values":["The E989 Muon $g-2$ Experiment aims to measure the anomalous magnetic moment of the muon, $a_\\mu$, to an unprecedented precision of 140 parts per billion (ppb). There currently stands a greater than 3$\\sigma$ discrepancy between the best measurement of $a_\\mu$ and its theoretical value predicted using the Standard Model. The E989 experiment seeks to either resolve or confirm this discrepancy, which is suggestive of new physics interactions within reach of many contemporary experiments. To achieve the E989 target precision, the anomalous precession frequency, $\\omega_a$, of muons in a magnetic storage ring must be determined with a systematic uncertainty below 70\\,ppb. This frequency is imprinted on the time-dependent energy distribution of decay positrons observed by 24 electromagnetic calorimeters. These calorimeters feature a novel design optimized expressly for the stringent demands of the $\\omega_a$ measurement. This dissertation outlines the motivation for and measurement principles behind E989, discusses the requirements, prototyping, testing, commissioning, and operations of the electromagnetic calorimeters, and presents a preliminary, blinded analysis of data collected in the spring of 2018."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Measuring the Precession Frequency in the E989 Muon g-2 Experiment"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hertzog, David W"],"dc:creator":["Fienberg, Aaron"],"dc:date.accessioned":["2019-05-02T23:21:50Z"],"dc:date.available":["2019-05-02T23:21:50Z"],"dc:date.issued":["2019-05-02"],"dc:date.submitted":["2019"],"dc:description":["Thesis (Ph.D.)--University of Washington, 2019"],"dc:description.abstract":["The E989 Muon $g-2$ Experiment aims to measure the anomalous magnetic moment of the muon, $a_\\mu$, to an unprecedented precision of 140 parts per billion (ppb). There currently stands a greater than 3$\\sigma$ discrepancy between the best measurement of $a_\\mu$ and its theoretical value predicted using the Standard Model. The E989 experiment seeks to either resolve or confirm this discrepancy, which is suggestive of new physics interactions within reach of many contemporary experiments. To achieve the E989 target precision, the anomalous precession frequency, $\\omega_a$, of muons in a magnetic storage ring must be determined with a systematic uncertainty below 70\\,ppb. This frequency is imprinted on the time-dependent energy distribution of decay positrons observed by 24 electromagnetic calorimeters. These calorimeters feature a novel design optimized expressly for the stringent demands of the $\\omega_a$ measurement. This dissertation outlines the motivation for and measurement principles behind E989, discusses the requirements, prototyping, testing, commissioning, and operations of the electromagnetic calorimeters, and presents a preliminary, blinded analysis of data collected in the spring of 2018."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Fienberg_washington_0250E_19639.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/43736"],"dc:language.iso":["en_US"],"dc:rights":["CC BY-NC-SA"],"dc:subject":["calorimeter","magnetic dipole moment","muon","precision","Physics"],"dc:subject.other":["Physics"],"dc:title":["Measuring the Precession Frequency in the E989 Muon g-2 Experiment"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:09:25Z"}