{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/45832"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/45832","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"3D Printed Polypyrrole Microneedle Arrays for Electronically Controlled Transdural Drug Release","abstract":"The secondary injury causes further damage to neural cells, due to mechanisms of inflammation and cytotoxicity. Progression of secondary injury damage may be reduced by the administration of anti-inflammatory drugs. In order to allow local delivery of such drugs, while minimizing dural opening, we have created a Polypyrrole (PPy) microneedle array using micro-scale 3D printing technology that facilitates electronically controlled encapsulation and transdural release of drugs. The PPy microneedles demonstrated electronically controlled transdural release of steroid dexamethasone (Dexa) in a novel in vitro transdural model. Drug release capabilities of the device were then tested by electronic release of Dexa into an in-vitro model of activated BV2 microglia. After 72 hours of incubation, inflammation was reduced, as demonstrated by measured release of nitric oxide and Il-1b, a pro-inflammatory cytokine. These results demonstrate the feasibility of PPy microneedles for transdural delivery of anti-inflammatory drugs for spinal cord injury.","abstract_html":"The secondary injury causes further damage to neural cells, due to mechanisms of inflammation and cytotoxicity. Progression of secondary injury damage may be reduced by the administration of anti-inflammatory drugs. In order to allow local delivery of such drugs, while minimizing dural opening, we have created a Polypyrrole (PPy) microneedle array using micro-scale 3D printing technology that facilitates electronically controlled encapsulation and transdural release of drugs. The PPy microneedles demonstrated electronically controlled transdural release of steroid dexamethasone (Dexa) in a novel in vitro transdural model. Drug release capabilities of the device were then tested by electronic release of Dexa into an in-vitro model of activated BV2 microglia. After 72 hours of incubation, inflammation was reduced, as demonstrated by measured release of nitric oxide and Il-1b, a pro-inflammatory cytokine. These results demonstrate the feasibility of PPy microneedles for transdural delivery of anti-inflammatory drugs for spinal cord injury.","abstract_has_math":false,"creators":["Huang, Joyce"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Saigal, Rajiv"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-08-14","date_published":"2020-08-14","updated_at":"2026-11-19T10:19:41Z","subjects":["Drug Delivery","Microneedles","Polypyrrole","Bioengineering"],"languages":["en_US"],"rights":["CC BY-NC-ND"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/45832","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/45832","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F45832","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Saigal, Rajiv"]},{"key":"dc:creator","label":"Author","values":["Huang, Joyce"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-08-14T03:26:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-08-14"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2021-08-14T03:26:07Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2020"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["PPy Microneedle Indentation 500nm max 35um.mp4; video; PPy Microneedle Indentation 500nm max 35um.","PPy Microneedle Indentation 150nm max 35um.mp4; video; PPy Microneedle Indentation 150nm max 35um.","PPy Microneedle Indentation 75nm max 20um.mp4; video; PPy Microneedle Indentation 75nm max 20um.","PPy Microneedle Indentation 17nm max 10um.mp4; video; PPy Microneedle Indentation 17nm max 10um."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Drug Delivery","Microneedles","Polypyrrole","Bioengineering"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["CC BY-NC-ND"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Huang_washington_0250O_21959.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/45832"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2020"]},{"key":"dc:description.abstract","label":"Abstract","values":["The secondary injury causes further damage to neural cells, due to mechanisms of inflammation and cytotoxicity. Progression of secondary injury damage may be reduced by the administration of anti-inflammatory drugs. In order to allow local delivery of such drugs, while minimizing dural opening, we have created a Polypyrrole (PPy) microneedle array using micro-scale 3D printing technology that facilitates electronically controlled encapsulation and transdural release of drugs. The PPy microneedles demonstrated electronically controlled transdural release of steroid dexamethasone (Dexa) in a novel in vitro transdural model. Drug release capabilities of the device were then tested by electronic release of Dexa into an in-vitro model of activated BV2 microglia. After 72 hours of incubation, inflammation was reduced, as demonstrated by measured release of nitric oxide and Il-1b, a pro-inflammatory cytokine. These results demonstrate the feasibility of PPy microneedles for transdural delivery of anti-inflammatory drugs for spinal cord injury."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Delay release for 1 year -- then make Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["3D Printed Polypyrrole Microneedle Arrays for Electronically Controlled Transdural Drug Release"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Saigal, Rajiv"],"dc:creator":["Huang, Joyce"],"dc:date.accessioned":["2020-08-14T03:26:07Z"],"dc:date.issued":["2020-08-14"],"dc:date.liftdate":["2021-08-14T03:26:07Z"],"dc:date.submitted":["2020"],"dc:description":["Thesis (Master's)--University of Washington, 2020"],"dc:description.abstract":["The secondary injury causes further damage to neural cells, due to mechanisms of inflammation and cytotoxicity. Progression of secondary injury damage may be reduced by the administration of anti-inflammatory drugs. In order to allow local delivery of such drugs, while minimizing dural opening, we have created a Polypyrrole (PPy) microneedle array using micro-scale 3D printing technology that facilitates electronically controlled encapsulation and transdural release of drugs. The PPy microneedles demonstrated electronically controlled transdural release of steroid dexamethasone (Dexa) in a novel in vitro transdural model. Drug release capabilities of the device were then tested by electronic release of Dexa into an in-vitro model of activated BV2 microglia. After 72 hours of incubation, inflammation was reduced, as demonstrated by measured release of nitric oxide and Il-1b, a pro-inflammatory cytokine. These results demonstrate the feasibility of PPy microneedles for transdural delivery of anti-inflammatory drugs for spinal cord injury."],"dc:embargo.terms":["Delay release for 1 year -- then make Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Huang_washington_0250O_21959.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/45832"],"dc:language.iso":["en_US"],"dc:relation.haspart":["PPy Microneedle Indentation 500nm max 35um.mp4; video; PPy Microneedle Indentation 500nm max 35um.","PPy Microneedle Indentation 150nm max 35um.mp4; video; PPy Microneedle Indentation 150nm max 35um.","PPy Microneedle Indentation 75nm max 20um.mp4; video; PPy Microneedle Indentation 75nm max 20um.","PPy Microneedle Indentation 17nm max 10um.mp4; video; PPy Microneedle Indentation 17nm max 10um."],"dc:rights":["CC BY-NC-ND"],"dc:subject":["Drug Delivery","Microneedles","Polypyrrole","Bioengineering"],"dc:subject.other":["Bioengineering"],"dc:title":["3D Printed Polypyrrole Microneedle Arrays for Electronically Controlled Transdural Drug Release"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:19:41Z"}