{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/52782"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/52782","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Modelling and Simulation of DFIG for wind energy applications using PWM converters","abstract":"This research work focuses on Double Fed Induction Generator Modelling and Simulation in wind energy conversion system applications. DFIG is one of the most common machines in modern wind power generation because of its capability to operate efficiently for a wide range of wind speeds. The design of the system consists of two back-to-back connected PWM converters through a dc link. In this scheme the stator of DFIG is connected to the grid directly, while rotor connected to the grid through two back-to-back converters and DC Link. A 2 MW DFIG system is modelled and simulated in the specialized power electronics tool PLECS. This work significantly demonstrates the ability to maintain grid stability which has been achieved by simulating the system under three different speeds for both regular and fault conditions. The simulation demonstrates that the system can keep normal grid parameters, manage energy transmission, and smooth transition between sub-synchronous, synchronous and super-synchronous zones, even during disturbances like a three-phase fault.","abstract_html":"This research work focuses on Double Fed Induction Generator Modelling and Simulation in wind energy conversion system applications. DFIG is one of the most common machines in modern wind power generation because of its capability to operate efficiently for a wide range of wind speeds. The design of the system consists of two back-to-back connected PWM converters through a dc link. In this scheme the stator of DFIG is connected to the grid directly, while rotor connected to the grid through two back-to-back converters and DC Link. A 2 MW DFIG system is modelled and simulated in the specialized power electronics tool PLECS. This work significantly demonstrates the ability to maintain grid stability which has been achieved by simulating the system under three different speeds for both regular and fault conditions. The simulation demonstrates that the system can keep normal grid parameters, manage energy transmission, and smooth transition between sub-synchronous, synchronous and super-synchronous zones, even during disturbances like a three-phase fault.","abstract_has_math":false,"creators":["Nandikolla, Naga Swathi"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Dargahi, Vahid"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-01-23","date_published":"2025-01-23","updated_at":"2026-11-19T10:20:28Z","subjects":["Electrical engineering","Energy","Electrical and computer engineering"],"languages":["en_US"],"rights":["none"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Nandikolla_washington_0250O_27800.pdf"],"render_values":[{"text":"Nandikolla_washington_0250O_27800.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1773/52782","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1773/52782","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F52782","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dargahi, Vahid"]},{"key":"dc:creator","label":"Author","values":["Nandikolla, Naga Swathi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-23T20:08:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-01-23"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2026-01-23T20:08:13Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2024"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical engineering","Energy"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Electrical and computer engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["none"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Nandikolla_washington_0250O_27800.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1773/52782"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2024"]},{"key":"dc:description.abstract","label":"Abstract","values":["This research work focuses on Double Fed Induction Generator Modelling and Simulation in wind energy conversion system applications. DFIG is one of the most common machines in modern wind power generation because of its capability to operate efficiently for a wide range of wind speeds. The design of the system consists of two back-to-back connected PWM converters through a dc link. In this scheme the stator of DFIG is connected to the grid directly, while rotor connected to the grid through two back-to-back converters and DC Link. A 2 MW DFIG system is modelled and simulated in the specialized power electronics tool PLECS. This work significantly demonstrates the ability to maintain grid stability which has been achieved by simulating the system under three different speeds for both regular and fault conditions. The simulation demonstrates that the system can keep normal grid parameters, manage energy transmission, and smooth transition between sub-synchronous, synchronous and super-synchronous zones, even during disturbances like a three-phase fault."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Restrict to UW for 1 year -- then make Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Modelling and Simulation of DFIG for wind energy applications using PWM converters"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dargahi, Vahid"],"dc:creator":["Nandikolla, Naga Swathi"],"dc:date.accessioned":["2025-01-23T20:08:13Z"],"dc:date.issued":["2025-01-23"],"dc:date.liftdate":["2026-01-23T20:08:13Z"],"dc:date.submitted":["2024"],"dc:description":["Thesis (Master's)--University of Washington, 2024"],"dc:description.abstract":["This research work focuses on Double Fed Induction Generator Modelling and Simulation in wind energy conversion system applications. DFIG is one of the most common machines in modern wind power generation because of its capability to operate efficiently for a wide range of wind speeds. The design of the system consists of two back-to-back connected PWM converters through a dc link. In this scheme the stator of DFIG is connected to the grid directly, while rotor connected to the grid through two back-to-back converters and DC Link. A 2 MW DFIG system is modelled and simulated in the specialized power electronics tool PLECS. This work significantly demonstrates the ability to maintain grid stability which has been achieved by simulating the system under three different speeds for both regular and fault conditions. The simulation demonstrates that the system can keep normal grid parameters, manage energy transmission, and smooth transition between sub-synchronous, synchronous and super-synchronous zones, even during disturbances like a three-phase fault."],"dc:embargo.terms":["Restrict to UW for 1 year -- then make Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Nandikolla_washington_0250O_27800.pdf"],"dc:identifier.uri":["https://hdl.handle.net/1773/52782"],"dc:language.iso":["en_US"],"dc:rights":["none"],"dc:subject":["Electrical engineering","Energy"],"dc:subject.other":["Electrical and computer engineering"],"dc:title":["Modelling and Simulation of DFIG for wind energy applications using PWM converters"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:20:28Z"}