{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/52820"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/52820","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Sensorless Contact Force Estimation on Raven II Surgical Robot Platform","abstract":"Haptic feedback in surgical robotic arms has long been a challenging area due to factors such as the need for sterilization, which complicates the mounting of force sensors on the end-effector, and the complex, nonlinear nature of cable-driven systems. In this work, I present a data collection procedure that enables contact force estimation without direct sensor measurements, using a learning-based approach. Additionally, a 6-degree-of-freedom (DOF) cable-driven haptic device was developed to apply known contact forces over a wide workspace. The device includes multiple direct-current (DC) motors and shear beam load cells, and a real-time feedback control system implemented using the Zephyr Real-Time Operating System (RTOS). A high-level controller synthesizes the desired contact forces. The device was tested on a Raven II Surgical Robot Arm, demonstrating its capabilityin applying precise contact forces, though certain limitations in the setup were identified. A one-directional contact force estimation experiment was conducted with a random force applied along the Y-axis, while the Raven-II followed a random trajectory. Three neural network models—MLP, LSTM, and GRU—were trained using the collected data, achieving mean absolute errors (MAE) of 0.5859, 0.6664, and 0.7486 N, respectively, within a force range of ±4.5 N. Further analysis revealed a correlation between joint velocities and estimation error, providing insights for designing more efficient training trajectories.","abstract_html":"Haptic feedback in surgical robotic arms has long been a challenging area due to factors such as the need for sterilization, which complicates the mounting of force sensors on the end-effector, and the complex, nonlinear nature of cable-driven systems. In this work, I present a data collection procedure that enables contact force estimation without direct sensor measurements, using a learning-based approach. Additionally, a 6-degree-of-freedom (DOF) cable-driven haptic device was developed to apply known contact forces over a wide workspace. The device includes multiple direct-current (DC) motors and shear beam load cells, and a real-time feedback control system implemented using the Zephyr Real-Time Operating System (RTOS). A high-level controller synthesizes the desired contact forces. The device was tested on a Raven II Surgical Robot Arm, demonstrating its capabilityin applying precise contact forces, though certain limitations in the setup were identified. A one-directional contact force estimation experiment was conducted with a random force applied along the Y-axis, while the Raven-II followed a random trajectory. Three neural network models—MLP, LSTM, and GRU—were trained using the collected data, achieving mean absolute errors (MAE) of 0.5859, 0.6664, and 0.7486 N, respectively, within a force range of ±4.5 N. Further analysis revealed a correlation between joint velocities and estimation error, providing insights for designing more efficient training trajectories.","abstract_has_math":false,"creators":["Chiang, Dun-Tin"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Hannaford, Blake"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-01-23","date_published":"2025-01-23","updated_at":"2026-11-18T20:08:40Z","subjects":["Cable Driven Parallel Robot","Contact Force Estimation","Data-Driven Modeling","Surgical Robot","Mechanical engineering","Electrical engineering","Robotics"],"languages":["en_US"],"rights":["CC BY-NC-SA"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1773/52820","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1773/52820","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F52820","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hannaford, Blake"]},{"key":"dc:creator","label":"Author","values":["Chiang, Dun-Tin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-23T20:10:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-23T20:10:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-01-23"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2024"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cable Driven Parallel Robot","Contact Force Estimation","Data-Driven Modeling","Surgical Robot","Mechanical engineering","Electrical engineering","Robotics"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["CC BY-NC-SA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Chiang_washington_0250O_27628.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1773/52820"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2024"]},{"key":"dc:description.abstract","label":"Abstract","values":["Haptic feedback in surgical robotic arms has long been a challenging area due to factors such as the need for sterilization, which complicates the mounting of force sensors on the end-effector, and the complex, nonlinear nature of cable-driven systems. In this work, I present a data collection procedure that enables contact force estimation without direct sensor measurements, using a learning-based approach. Additionally, a 6-degree-of-freedom (DOF) cable-driven haptic device was developed to apply known contact forces over a wide workspace. The device includes multiple direct-current (DC) motors and shear beam load cells, and a real-time feedback control system implemented using the Zephyr Real-Time Operating System (RTOS). A high-level controller synthesizes the desired contact forces. The device was tested on a Raven II Surgical Robot Arm, demonstrating its capabilityin applying precise contact forces, though certain limitations in the setup were identified. A one-directional contact force estimation experiment was conducted with a random force applied along the Y-axis, while the Raven-II followed a random trajectory. Three neural network models—MLP, LSTM, and GRU—were trained using the collected data, achieving mean absolute errors (MAE) of 0.5859, 0.6664, and 0.7486 N, respectively, within a force range of ±4.5 N. Further analysis revealed a correlation between joint velocities and estimation error, providing insights for designing more efficient training trajectories."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Sensorless Contact Force Estimation on Raven II Surgical Robot Platform"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hannaford, Blake"],"dc:creator":["Chiang, Dun-Tin"],"dc:date.accessioned":["2025-01-23T20:10:43Z"],"dc:date.available":["2025-01-23T20:10:43Z"],"dc:date.issued":["2025-01-23"],"dc:date.submitted":["2024"],"dc:description":["Thesis (Master's)--University of Washington, 2024"],"dc:description.abstract":["Haptic feedback in surgical robotic arms has long been a challenging area due to factors such as the need for sterilization, which complicates the mounting of force sensors on the end-effector, and the complex, nonlinear nature of cable-driven systems. In this work, I present a data collection procedure that enables contact force estimation without direct sensor measurements, using a learning-based approach. Additionally, a 6-degree-of-freedom (DOF) cable-driven haptic device was developed to apply known contact forces over a wide workspace. The device includes multiple direct-current (DC) motors and shear beam load cells, and a real-time feedback control system implemented using the Zephyr Real-Time Operating System (RTOS). A high-level controller synthesizes the desired contact forces. The device was tested on a Raven II Surgical Robot Arm, demonstrating its capabilityin applying precise contact forces, though certain limitations in the setup were identified. A one-directional contact force estimation experiment was conducted with a random force applied along the Y-axis, while the Raven-II followed a random trajectory. Three neural network models—MLP, LSTM, and GRU—were trained using the collected data, achieving mean absolute errors (MAE) of 0.5859, 0.6664, and 0.7486 N, respectively, within a force range of ±4.5 N. Further analysis revealed a correlation between joint velocities and estimation error, providing insights for designing more efficient training trajectories."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Chiang_washington_0250O_27628.pdf"],"dc:identifier.uri":["https://hdl.handle.net/1773/52820"],"dc:language.iso":["en_US"],"dc:rights":["CC BY-NC-SA"],"dc:subject":["Cable Driven Parallel Robot","Contact Force Estimation","Data-Driven Modeling","Surgical Robot","Mechanical engineering","Electrical engineering","Robotics"],"dc:subject.other":["Mechanical engineering"],"dc:title":["Sensorless Contact Force Estimation on Raven II Surgical Robot Platform"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:08:40Z"}