{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/53404"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/53404","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Machine Learning Framework for Early Prediction of Ventricular Tachycardia Using Single-Lead Electrocardiogram Signals","abstract":"This study presents a machine learning framework designed for early prediction of ventricular tachycardia (VT) using single-lead electrocardiogram (ECG) signals collected from portable monitoring devices. Unlike prior studies that relied heavily on hospital-based data or incorporated additional demographic information, this work enhances applicability for out-of-hospital patient care. Three modeling approaches were explored: a Long Short-Term Memory (LSTM) model, 2D Convolutional Neural Networks (CNN) trained on spectrograms, and a Support Vector Machine (SVM) using features extracted by a Variational Auto-Encoder (VAE). Among these, the VAE-SVM model demonstrated superior performance, achieving an F1 score of 0.66 and a recall of 0.77. Explainable AI techniques, latent space traversal, and correlation analysis were applied to interpret model behavior and identify physiologically meaningful features associated with VT onset. These findings highlight a valuable opportunity for developing wearable-based VT detection tools that can be integrated into daily health monitoring systems.","abstract_html":"This study presents a machine learning framework designed for early prediction of ventricular tachycardia (VT) using single-lead electrocardiogram (ECG) signals collected from portable monitoring devices. Unlike prior studies that relied heavily on hospital-based data or incorporated additional demographic information, this work enhances applicability for out-of-hospital patient care. Three modeling approaches were explored: a Long Short-Term Memory (LSTM) model, 2D Convolutional Neural Networks (CNN) trained on spectrograms, and a Support Vector Machine (SVM) using features extracted by a Variational Auto-Encoder (VAE). Among these, the VAE-SVM model demonstrated superior performance, achieving an F1 score of 0.66 and a recall of 0.77. Explainable AI techniques, latent space traversal, and correlation analysis were applied to interpret model behavior and identify physiologically meaningful features associated with VT onset. These findings highlight a valuable opportunity for developing wearable-based VT detection tools that can be integrated into daily health monitoring systems.","abstract_has_math":false,"creators":["Yeh, Shu-Yi"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Boyle, Patrick M"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-08-01","date_published":"2025-08-01","updated_at":"2026-11-18T20:06:28Z","subjects":["Electrocardiogram","Machine Learning","Portable Health Monitoring","Variational Autoencoder","Ventricular Tachycardia","Bioengineering"],"languages":["en_US"],"rights":["none"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1773/53404","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1773/53404","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F53404","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Boyle, Patrick M"]},{"key":"dc:creator","label":"Author","values":["Yeh, Shu-Yi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-01T22:16:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-01T22:16:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-08-01"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrocardiogram","Machine Learning","Portable Health Monitoring","Variational Autoencoder","Ventricular Tachycardia","Bioengineering"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["none"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Yeh_washington_0250O_28246.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1773/53404"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2025"]},{"key":"dc:description.abstract","label":"Abstract","values":["This study presents a machine learning framework designed for early prediction of ventricular tachycardia (VT) using single-lead electrocardiogram (ECG) signals collected from portable monitoring devices. Unlike prior studies that relied heavily on hospital-based data or incorporated additional demographic information, this work enhances applicability for out-of-hospital patient care. Three modeling approaches were explored: a Long Short-Term Memory (LSTM) model, 2D Convolutional Neural Networks (CNN) trained on spectrograms, and a Support Vector Machine (SVM) using features extracted by a Variational Auto-Encoder (VAE). Among these, the VAE-SVM model demonstrated superior performance, achieving an F1 score of 0.66 and a recall of 0.77. Explainable AI techniques, latent space traversal, and correlation analysis were applied to interpret model behavior and identify physiologically meaningful features associated with VT onset. These findings highlight a valuable opportunity for developing wearable-based VT detection tools that can be integrated into daily health monitoring systems."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Machine Learning Framework for Early Prediction of Ventricular Tachycardia Using Single-Lead Electrocardiogram Signals"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Boyle, Patrick M"],"dc:creator":["Yeh, Shu-Yi"],"dc:date.accessioned":["2025-08-01T22:16:06Z"],"dc:date.available":["2025-08-01T22:16:06Z"],"dc:date.issued":["2025-08-01"],"dc:date.submitted":["2025"],"dc:description":["Thesis (Master's)--University of Washington, 2025"],"dc:description.abstract":["This study presents a machine learning framework designed for early prediction of ventricular tachycardia (VT) using single-lead electrocardiogram (ECG) signals collected from portable monitoring devices. Unlike prior studies that relied heavily on hospital-based data or incorporated additional demographic information, this work enhances applicability for out-of-hospital patient care. Three modeling approaches were explored: a Long Short-Term Memory (LSTM) model, 2D Convolutional Neural Networks (CNN) trained on spectrograms, and a Support Vector Machine (SVM) using features extracted by a Variational Auto-Encoder (VAE). Among these, the VAE-SVM model demonstrated superior performance, achieving an F1 score of 0.66 and a recall of 0.77. Explainable AI techniques, latent space traversal, and correlation analysis were applied to interpret model behavior and identify physiologically meaningful features associated with VT onset. These findings highlight a valuable opportunity for developing wearable-based VT detection tools that can be integrated into daily health monitoring systems."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Yeh_washington_0250O_28246.pdf"],"dc:identifier.uri":["https://hdl.handle.net/1773/53404"],"dc:language.iso":["en_US"],"dc:rights":["none"],"dc:subject":["Electrocardiogram","Machine Learning","Portable Health Monitoring","Variational Autoencoder","Ventricular Tachycardia","Bioengineering"],"dc:subject.other":["Bioengineering"],"dc:title":["Machine Learning Framework for Early Prediction of Ventricular Tachycardia Using Single-Lead Electrocardiogram Signals"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:06:28Z"}