{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/53406"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/53406","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Development, optimization, and validation of quantitative lateral flow assays for accessible, at-home biomarker monitoring","abstract":"Many chronic autoimmune disorders, like Rheumatoid arthritis and psoriasis, are characterized by painful joint inflammation and extreme fatigue. Patient outcomes are significantly improved by early treatment interventions, which can be enabled through information from continuous monitoring and early detection. The current standard for diagnosis and monitoring of these diseases is laboratory-based testing for the quantification of specific biomarkers. Frequent laboratory blood tests are not feasible for all patients or universally accessible, so a low-cost, point-of-care monitoring solution could improve the monitoring of autoimmune disorders and even provide quantitative metrics of treatment efficacy. The field of paper microfluidics has become a significant source of new tools that expand healthcare accessibility, particularly when designed to be robust in various environments. Innovations in this field have included the use of lateral flow assays and freeze-dried reagents to create portable and accurate testing devices. Here, we present the development of two quantitative sensing techniques for sandwich lateral flow immunoassays, which enable sensitivity to analytes present in two different concentration regimes (one being 1 million times more dilute than the other). The results indicate the utility and readiness of two immunoassays for translation into a paper-based, multiplexed, at-home biomarker monitoring platform.","abstract_html":"Many chronic autoimmune disorders, like Rheumatoid arthritis and psoriasis, are characterized by painful joint inflammation and extreme fatigue. Patient outcomes are significantly improved by early treatment interventions, which can be enabled through information from continuous monitoring and early detection. The current standard for diagnosis and monitoring of these diseases is laboratory-based testing for the quantification of specific biomarkers. Frequent laboratory blood tests are not feasible for all patients or universally accessible, so a low-cost, point-of-care monitoring solution could improve the monitoring of autoimmune disorders and even provide quantitative metrics of treatment efficacy. The field of paper microfluidics has become a significant source of new tools that expand healthcare accessibility, particularly when designed to be robust in various environments. Innovations in this field have included the use of lateral flow assays and freeze-dried reagents to create portable and accurate testing devices. Here, we present the development of two quantitative sensing techniques for sandwich lateral flow immunoassays, which enable sensitivity to analytes present in two different concentration regimes (one being 1 million times more dilute than the other). The results indicate the utility and readiness of two immunoassays for translation into a paper-based, multiplexed, at-home biomarker monitoring platform.","abstract_has_math":false,"creators":["Staats, Ethan Lewis"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Yager, Paul"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-08-01","date_published":"2025-08-01","updated_at":"2026-11-19T10:20:28Z","subjects":["accessible","immunoassay","lateral flow assay","monitoring","point-of-care","quantitative","Bioengineering"],"languages":["en_US"],"rights":["CC BY"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1773/53406","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1773/53406","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F53406","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yager, Paul"]},{"key":"dc:creator","label":"Author","values":["Staats, Ethan Lewis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-01T22:16:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-08-01"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2027-07-22T22:16:07Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["accessible","immunoassay","lateral flow assay","monitoring","point-of-care","quantitative","Bioengineering"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["CC BY"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Staats_washington_0250O_28371.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1773/53406"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2025"]},{"key":"dc:description.abstract","label":"Abstract","values":["Many chronic autoimmune disorders, like Rheumatoid arthritis and psoriasis, are characterized by painful joint inflammation and extreme fatigue. Patient outcomes are significantly improved by early treatment interventions, which can be enabled through information from continuous monitoring and early detection. The current standard for diagnosis and monitoring of these diseases is laboratory-based testing for the quantification of specific biomarkers. Frequent laboratory blood tests are not feasible for all patients or universally accessible, so a low-cost, point-of-care monitoring solution could improve the monitoring of autoimmune disorders and even provide quantitative metrics of treatment efficacy. The field of paper microfluidics has become a significant source of new tools that expand healthcare accessibility, particularly when designed to be robust in various environments. Innovations in this field have included the use of lateral flow assays and freeze-dried reagents to create portable and accurate testing devices. Here, we present the development of two quantitative sensing techniques for sandwich lateral flow immunoassays, which enable sensitivity to analytes present in two different concentration regimes (one being 1 million times more dilute than the other). The results indicate the utility and readiness of two immunoassays for translation into a paper-based, multiplexed, at-home biomarker monitoring platform."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Restrict to UW for 2 years -- then make Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development, optimization, and validation of quantitative lateral flow assays for accessible, at-home biomarker monitoring"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yager, Paul"],"dc:creator":["Staats, Ethan Lewis"],"dc:date.accessioned":["2025-08-01T22:16:07Z"],"dc:date.issued":["2025-08-01"],"dc:date.liftdate":["2027-07-22T22:16:07Z"],"dc:date.submitted":["2025"],"dc:description":["Thesis (Master's)--University of Washington, 2025"],"dc:description.abstract":["Many chronic autoimmune disorders, like Rheumatoid arthritis and psoriasis, are characterized by painful joint inflammation and extreme fatigue. Patient outcomes are significantly improved by early treatment interventions, which can be enabled through information from continuous monitoring and early detection. The current standard for diagnosis and monitoring of these diseases is laboratory-based testing for the quantification of specific biomarkers. Frequent laboratory blood tests are not feasible for all patients or universally accessible, so a low-cost, point-of-care monitoring solution could improve the monitoring of autoimmune disorders and even provide quantitative metrics of treatment efficacy. The field of paper microfluidics has become a significant source of new tools that expand healthcare accessibility, particularly when designed to be robust in various environments. Innovations in this field have included the use of lateral flow assays and freeze-dried reagents to create portable and accurate testing devices. Here, we present the development of two quantitative sensing techniques for sandwich lateral flow immunoassays, which enable sensitivity to analytes present in two different concentration regimes (one being 1 million times more dilute than the other). The results indicate the utility and readiness of two immunoassays for translation into a paper-based, multiplexed, at-home biomarker monitoring platform."],"dc:embargo.terms":["Restrict to UW for 2 years -- then make Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Staats_washington_0250O_28371.pdf"],"dc:identifier.uri":["https://hdl.handle.net/1773/53406"],"dc:language.iso":["en_US"],"dc:rights":["CC BY"],"dc:subject":["accessible","immunoassay","lateral flow assay","monitoring","point-of-care","quantitative","Bioengineering"],"dc:subject.other":["Bioengineering"],"dc:title":["Development, optimization, and validation of quantitative lateral flow assays for accessible, at-home biomarker monitoring"],"dc:type":["Thesis"],"others:access_status":["embargo"]},"updated_at":"2026-11-19T10:20:28Z"}