{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/54054"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/54054","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Development and Validation of a Modular, Realistic IV Placement Training Model (PractIV)","abstract":"This thesis presents the development of PractIV, a modular peripheral intravenous (PIV) training simulator designed to improve realism, adaptability, and integration of IV placement training for healthcare professionals. The research project is a collaboration with the University of Washington (UW) Mechanical Engineering 'Engineering in Health' (EIH) Program, and the Center for Research in Education and Simulation Technologies (CREST) at UW. The goal of this work is to develop a modular IV arm trainer specifically designed to comply with the Modular Healthcare Simulation and Education System (MoHSES™) physical connection standards, enabling seamless integration with existing manikins such as the Advanced Joint Airway Management System (AJAMS), Both previously developed by CREST. PractIV addresses key limitations in existing IV training tools, which often lack anatomical realism and fail to prepare learners for challenging patient scenarios. By combining insights from clinical practice, mechanical design, and additive manufacturing, this work contributes to the fields of medical simulator development and IV training.","abstract_html":"This thesis presents the development of PractIV, a modular peripheral intravenous (PIV) training simulator designed to improve realism, adaptability, and integration of IV placement training for healthcare professionals. The research project is a collaboration with the University of Washington (UW) Mechanical Engineering &#x27;Engineering in Health&#x27; (EIH) Program, and the Center for Research in Education and Simulation Technologies (CREST) at UW. The goal of this work is to develop a modular IV arm trainer specifically designed to comply with the Modular Healthcare Simulation and Education System (MoHSES™) physical connection standards, enabling seamless integration with existing manikins such as the Advanced Joint Airway Management System (AJAMS), Both previously developed by CREST. PractIV addresses key limitations in existing IV training tools, which often lack anatomical realism and fail to prepare learners for challenging patient scenarios. By combining insights from clinical practice, mechanical design, and additive manufacturing, this work contributes to the fields of medical simulator development and IV training.","abstract_has_math":false,"creators":["Cowin, Liam Christopher"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Reinhall, Per"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-10-02","date_published":"2025-10-02","updated_at":"2026-11-18T20:04:57Z","subjects":["Additive Manufacturing","Anatomical Model","IV Training","Medical Simulation","nTop","User Centered Design","Biomechanics","Biomedical engineering","Mechanical engineering"],"languages":["en_US"],"rights":["none"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1773/54054","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1773/54054","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F54054","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Reinhall, Per"]},{"key":"dc:creator","label":"Author","values":["Cowin, Liam Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-10-02T16:11:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-10-02T16:11:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-10-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Additive Manufacturing","Anatomical Model","IV Training","Medical Simulation","nTop","User Centered Design","Biomechanics","Biomedical engineering"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["none"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Cowin_washington_0250O_28744.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1773/54054"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2025"]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the development of PractIV, a modular peripheral intravenous (PIV) training simulator designed to improve realism, adaptability, and integration of IV placement training for healthcare professionals. The research project is a collaboration with the University of Washington (UW) Mechanical Engineering 'Engineering in Health' (EIH) Program, and the Center for Research in Education and Simulation Technologies (CREST) at UW. The goal of this work is to develop a modular IV arm trainer specifically designed to comply with the Modular Healthcare Simulation and Education System (MoHSES™) physical connection standards, enabling seamless integration with existing manikins such as the Advanced Joint Airway Management System (AJAMS), Both previously developed by CREST. PractIV addresses key limitations in existing IV training tools, which often lack anatomical realism and fail to prepare learners for challenging patient scenarios. By combining insights from clinical practice, mechanical design, and additive manufacturing, this work contributes to the fields of medical simulator development and IV training."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development and Validation of a Modular, Realistic IV Placement Training Model (PractIV)"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Reinhall, Per"],"dc:creator":["Cowin, Liam Christopher"],"dc:date.accessioned":["2025-10-02T16:11:44Z"],"dc:date.available":["2025-10-02T16:11:44Z"],"dc:date.issued":["2025-10-02"],"dc:date.submitted":["2025"],"dc:description":["Thesis (Master's)--University of Washington, 2025"],"dc:description.abstract":["This thesis presents the development of PractIV, a modular peripheral intravenous (PIV) training simulator designed to improve realism, adaptability, and integration of IV placement training for healthcare professionals. The research project is a collaboration with the University of Washington (UW) Mechanical Engineering 'Engineering in Health' (EIH) Program, and the Center for Research in Education and Simulation Technologies (CREST) at UW. The goal of this work is to develop a modular IV arm trainer specifically designed to comply with the Modular Healthcare Simulation and Education System (MoHSES™) physical connection standards, enabling seamless integration with existing manikins such as the Advanced Joint Airway Management System (AJAMS), Both previously developed by CREST. PractIV addresses key limitations in existing IV training tools, which often lack anatomical realism and fail to prepare learners for challenging patient scenarios. By combining insights from clinical practice, mechanical design, and additive manufacturing, this work contributes to the fields of medical simulator development and IV training."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Cowin_washington_0250O_28744.pdf"],"dc:identifier.uri":["https://hdl.handle.net/1773/54054"],"dc:language.iso":["en_US"],"dc:rights":["none"],"dc:subject":["Additive Manufacturing","Anatomical Model","IV Training","Medical Simulation","nTop","User Centered Design","Biomechanics","Biomedical engineering"],"dc:subject.other":["Mechanical engineering"],"dc:title":["Development and Validation of a Modular, Realistic IV Placement Training Model (PractIV)"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:04:57Z"}