{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/57448"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/57448","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Patient-Specific Finite Element Analysis of Stress Redistribution and Adjacent Vertebral Fracture Risk Following Cement Augmentation Toward Predictive Adjacent Fracture Modeling in Pre/Post-Operative Vertebroplasty for Cancer Relief","abstract":"This thesis develops a patient-specific finite element analysis (FEA) framework to evaluate stress redistribution and adjacent vertebral fracture risk following vertebroplasty with polymethyl methacrylate (PMMA) cement. Using CT-derived DICOM data, individualized vertebral geometries and cement morphologies were segmented, reconstructed, and assembled into a tri-vertebral model subjected to physiologically relevant compressive loads. Results show that while PMMA significantly reduces strain and stabilizes the treated vertebra, it creates a stiffness mismatch that redistributes stress to adjacent levels, producing elevated stress concentrations at vertebral endplates. These stress patterns align with clinically observed adjacent-level fractures and are strongly influenced by cement volume, geometry, and spatial distribution. The study develops a framework and demonstrates the potential of CT-driven, patient-specific FEA as a predictive tool for optimizing vertebroplasty planning and reducing post-operative fracture risk.","abstract_html":"This thesis develops a patient-specific finite element analysis (FEA) framework to evaluate stress redistribution and adjacent vertebral fracture risk following vertebroplasty with polymethyl methacrylate (PMMA) cement. Using CT-derived DICOM data, individualized vertebral geometries and cement morphologies were segmented, reconstructed, and assembled into a tri-vertebral model subjected to physiologically relevant compressive loads. Results show that while PMMA significantly reduces strain and stabilizes the treated vertebra, it creates a stiffness mismatch that redistributes stress to adjacent levels, producing elevated stress concentrations at vertebral endplates. These stress patterns align with clinically observed adjacent-level fractures and are strongly influenced by cement volume, geometry, and spatial distribution. The study develops a framework and demonstrates the potential of CT-driven, patient-specific FEA as a predictive tool for optimizing vertebroplasty planning and reducing post-operative fracture risk.","abstract_has_math":false,"creators":["Gugig, Daniel"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Som, Avik"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-08-11","date_published":"2026-08-11","updated_at":"2026-11-18T20:02:14Z","subjects":["Bioengineering","Oncology","Engineering","Materials science and engineering"],"languages":["en_US"],"rights":["none"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1773/57448","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1773/57448","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F57448","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Som, Avik"]},{"key":"dc:creator","label":"Author","values":["Gugig, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-08-11T19:32:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-08-11"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2026"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bioengineering","Oncology","Engineering"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Materials science and engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["none"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Gugig_washington_0250O_29922.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1773/57448"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2026"]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis develops a patient-specific finite element analysis (FEA) framework to evaluate stress redistribution and adjacent vertebral fracture risk following vertebroplasty with polymethyl methacrylate (PMMA) cement. Using CT-derived DICOM data, individualized vertebral geometries and cement morphologies were segmented, reconstructed, and assembled into a tri-vertebral model subjected to physiologically relevant compressive loads. Results show that while PMMA significantly reduces strain and stabilizes the treated vertebra, it creates a stiffness mismatch that redistributes stress to adjacent levels, producing elevated stress concentrations at vertebral endplates. These stress patterns align with clinically observed adjacent-level fractures and are strongly influenced by cement volume, geometry, and spatial distribution. The study develops a framework and demonstrates the potential of CT-driven, patient-specific FEA as a predictive tool for optimizing vertebroplasty planning and reducing post-operative fracture risk."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["Open Access"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Patient-Specific Finite Element Analysis of Stress Redistribution and Adjacent Vertebral Fracture Risk Following Cement Augmentation Toward Predictive Adjacent Fracture Modeling in Pre/Post-Operative Vertebroplasty for Cancer Relief"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Som, Avik"],"dc:creator":["Gugig, Daniel"],"dc:date.accessioned":["2026-08-11T19:32:38Z"],"dc:date.issued":["2026-08-11"],"dc:date.submitted":["2026"],"dc:description":["Thesis (Master's)--University of Washington, 2026"],"dc:description.abstract":["This thesis develops a patient-specific finite element analysis (FEA) framework to evaluate stress redistribution and adjacent vertebral fracture risk following vertebroplasty with polymethyl methacrylate (PMMA) cement. Using CT-derived DICOM data, individualized vertebral geometries and cement morphologies were segmented, reconstructed, and assembled into a tri-vertebral model subjected to physiologically relevant compressive loads. Results show that while PMMA significantly reduces strain and stabilizes the treated vertebra, it creates a stiffness mismatch that redistributes stress to adjacent levels, producing elevated stress concentrations at vertebral endplates. These stress patterns align with clinically observed adjacent-level fractures and are strongly influenced by cement volume, geometry, and spatial distribution. The study develops a framework and demonstrates the potential of CT-driven, patient-specific FEA as a predictive tool for optimizing vertebroplasty planning and reducing post-operative fracture risk."],"dc:embargo.terms":["Open Access"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Gugig_washington_0250O_29922.pdf"],"dc:identifier.uri":["https://hdl.handle.net/1773/57448"],"dc:language.iso":["en_US"],"dc:rights":["none"],"dc:subject":["Bioengineering","Oncology","Engineering"],"dc:subject.other":["Materials science and engineering"],"dc:title":["Patient-Specific Finite Element Analysis of Stress Redistribution and Adjacent Vertebral Fracture Risk Following Cement Augmentation Toward Predictive Adjacent Fracture Modeling in Pre/Post-Operative Vertebroplasty for Cancer Relief"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:02:14Z"}