{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/9668"},"canonical_url":"https://search.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/9668","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Toward a measurement of atomic parity nonconservation using a single, trapped barium ion","abstract":"A single, trapped barium ion presents an excellent opportunity to make a precise atomic parity nonconservation measurement. The relatively perturbation-free single-ion trapping environment and high efficiency shelving techniques can in principle be used to achieve an experimental precision at the 0.3% level or better. This accuracy range would permit us to make statements about the existence of new physics beyond the Standard Model. The weak interaction in Ba+ modifies the light shift induced in the ground state by an intense laser beam, adding a parity-violating contribution to the Larmor precession frequency of the electron spin in the Ba+ ground state. This thesis presents and describes the apparatus and techniques for completing the intended measurement and also presents the results of several, successful, preliminary measurements using this system.","abstract_html":"A single, trapped barium ion presents an excellent opportunity to make a precise atomic parity nonconservation measurement. The relatively perturbation-free single-ion trapping environment and high efficiency shelving techniques can in principle be used to achieve an experimental precision at the 0.3% level or better. This accuracy range would permit us to make statements about the existence of new physics beyond the Standard Model. The weak interaction in Ba+ modifies the light shift induced in the ground state by an intense laser beam, adding a parity-violating contribution to the Larmor precession frequency of the electron spin in the Ba+ ground state. This thesis presents and describes the apparatus and techniques for completing the intended measurement and also presents the results of several, successful, preliminary measurements using this system.","abstract_has_math":false,"creators":["Hendrickson, Kristi R. G. (Kristi Rae Gayle), 1969-"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999","date_published":"1999","updated_at":"2026-11-18T20:08:27Z","subjects":["Theses--Physics"],"languages":["en_US"],"rights":["Copyright is held by the individual authors."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["b43879275","43941552","Thesis 48625"],"render_values":[{"text":"b43879275","href":null,"code":true},{"text":"43941552","href":null,"code":true},{"text":"Thesis 48625","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/9668","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1773/9668","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.lib.washington.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.lib.washington.edu%3A1773%2F9668","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hendrickson, Kristi R. G. (Kristi Rae Gayle), 1969-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-10-07T00:10:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-10-07T00:10:35Z"]},{"key":"dc:date.issued","label":"Date","values":["1999"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Theses--Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright is held by the individual authors."]},{"key":"dc:rights.uri","label":"Rights URI","values":["For information on access and permissions, please see http://digital.lib.washington.edu/rw-faq/rights.html"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["b43879275","43941552","Thesis 48625"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/9668"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--University of Washington, 1999"]},{"key":"dc:description.abstract","label":"Abstract","values":["A single, trapped barium ion presents an excellent opportunity to make a precise atomic parity nonconservation measurement. The relatively perturbation-free single-ion trapping environment and high efficiency shelving techniques can in principle be used to achieve an experimental precision at the 0.3% level or better. This accuracy range would permit us to make statements about the existence of new physics beyond the Standard Model. The weak interaction in Ba+ modifies the light shift induced in the ground state by an intense laser beam, adding a parity-violating contribution to the Larmor precession frequency of the electron spin in the Ba+ ground state. This thesis presents and describes the apparatus and techniques for completing the intended measurement and also presents the results of several, successful, preliminary measurements using this system."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xii, 153 p."]},{"key":"dc:title","label":"Title","values":["Toward a measurement of atomic parity nonconservation using a single, trapped barium ion"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Hendrickson, Kristi R. G. (Kristi Rae Gayle), 1969-"],"dc:date.accessioned":["2009-10-07T00:10:35Z"],"dc:date.available":["2009-10-07T00:10:35Z"],"dc:date.issued":["1999"],"dc:description":["Thesis (Ph. D.)--University of Washington, 1999"],"dc:description.abstract":["A single, trapped barium ion presents an excellent opportunity to make a precise atomic parity nonconservation measurement. The relatively perturbation-free single-ion trapping environment and high efficiency shelving techniques can in principle be used to achieve an experimental precision at the 0.3% level or better. This accuracy range would permit us to make statements about the existence of new physics beyond the Standard Model. The weak interaction in Ba+ modifies the light shift induced in the ground state by an intense laser beam, adding a parity-violating contribution to the Larmor precession frequency of the electron spin in the Ba+ ground state. This thesis presents and describes the apparatus and techniques for completing the intended measurement and also presents the results of several, successful, preliminary measurements using this system."],"dc:format.extent":["xii, 153 p."],"dc:identifier.other":["b43879275","43941552","Thesis 48625"],"dc:identifier.uri":["http://hdl.handle.net/1773/9668"],"dc:language.iso":["en_US"],"dc:rights":["Copyright is held by the individual authors."],"dc:rights.uri":["For information on access and permissions, please see http://digital.lib.washington.edu/rw-faq/rights.html"],"dc:subject.other":["Theses--Physics"],"dc:title":["Toward a measurement of atomic parity nonconservation using a single, trapped barium ion"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T20:08:27Z"}