{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/14972"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/14972","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"Modeling Cumulative Arm Fatigue on Large Multi-touch Displays","abstract":"Large multi-touch displays have long been studied in the lab, and are beginning to see widespread deployment in public spaces. Although they are technologically feasible, research has found that large multi-touch displays are not always used, and that fatigue is commonly identified as a significant barrier. Fatigue, often called the `gorilla arm' effect, prevents people from using large displays for extended periods of time. One solution to this problem is to design large-scale interfaces that can minimize actual fatigue in practice. A first step towards building such an interface is to quantify fatigue, and more importantly, to quantify it easily. While there have been methods developed to estimate arm fatigue in mid-air interaction, there remains little understanding of fatigue on touch-based interfaces. To address this gap, we propose that existing models for mid-air interaction may be effective for measuring fatigue on large multi-touch displays. We evaluated the accuracy of Jang et al.'s mid-air Cumulative Fatigue model for touch interaction tasks on a large display. We found that their model underestimates subjective fatigue for multi-touch interaction, but can provide accurate estimates of subjective fatigue after fine-tuning of model parameters. We discuss the implications of this finding, and the need to further develop tools to evaluate fatigue on large, multi-touch displays.","abstract_html":"Large multi-touch displays have long been studied in the lab, and are beginning to see widespread deployment in public spaces. Although they are technologically feasible, research has found that large multi-touch displays are not always used, and that fatigue is commonly identified as a significant barrier. Fatigue, often called the `gorilla arm&#x27; effect, prevents people from using large displays for extended periods of time. One solution to this problem is to design large-scale interfaces that can minimize actual fatigue in practice. A first step towards building such an interface is to quantify fatigue, and more importantly, to quantify it easily. While there have been methods developed to estimate arm fatigue in mid-air interaction, there remains little understanding of fatigue on touch-based interfaces. To address this gap, we propose that existing models for mid-air interaction may be effective for measuring fatigue on large multi-touch displays. We evaluated the accuracy of Jang et al.&#x27;s mid-air Cumulative Fatigue model for touch interaction tasks on a large display. We found that their model underestimates subjective fatigue for multi-touch interaction, but can provide accurate estimates of subjective fatigue after fine-tuning of model parameters. We discuss the implications of this finding, and the need to further develop tools to evaluate fatigue on large, multi-touch displays.","abstract_has_math":false,"creators":["Liu, Zhe"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Wallace, James","Vogel, Daniel"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-08-28","date_published":"2019-08-28","updated_at":"2026-11-19T10:54:28Z","subjects":["Fatigue","Large Display","Multi-touch"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10012/14972","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10012/14972","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F14972","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wallace, James","Vogel, Daniel"]},{"key":"dc:creator","label":"Author","values":["Liu, Zhe"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-08-28T14:55:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-28T14:55:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-08-28"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2019-08-23"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fatigue","Large Display","Multi-touch"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10012/14972"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Large multi-touch displays have long been studied in the lab, and are beginning to see widespread deployment in public spaces. Although they are technologically feasible, research has found that large multi-touch displays are not always used, and that fatigue is commonly identified as a significant barrier. Fatigue, often called the `gorilla arm' effect, prevents people from using large displays for extended periods of time. One solution to this problem is to design large-scale interfaces that can minimize actual fatigue in practice. A first step towards building such an interface is to quantify fatigue, and more importantly, to quantify it easily. While there have been methods developed to estimate arm fatigue in mid-air interaction, there remains little understanding of fatigue on touch-based interfaces. To address this gap, we propose that existing models for mid-air interaction may be effective for measuring fatigue on large multi-touch displays. We evaluated the accuracy of Jang et al.'s mid-air Cumulative Fatigue model for touch interaction tasks on a large display. We found that their model underestimates subjective fatigue for multi-touch interaction, but can provide accurate estimates of subjective fatigue after fine-tuning of model parameters. We discuss the implications of this finding, and the need to further develop tools to evaluate fatigue on large, multi-touch displays."]},{"key":"dc:title","label":"Title","values":["Modeling Cumulative Arm Fatigue on Large Multi-touch Displays"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wallace, James","Vogel, Daniel"],"dc:creator":["Liu, Zhe"],"dc:date.accessioned":["2019-08-28T14:55:43Z"],"dc:date.available":["2019-08-28T14:55:43Z"],"dc:date.issued":["2019-08-28"],"dc:date.submitted":["2019-08-23"],"dc:description.abstract":["Large multi-touch displays have long been studied in the lab, and are beginning to see widespread deployment in public spaces. Although they are technologically feasible, research has found that large multi-touch displays are not always used, and that fatigue is commonly identified as a significant barrier. Fatigue, often called the `gorilla arm' effect, prevents people from using large displays for extended periods of time. One solution to this problem is to design large-scale interfaces that can minimize actual fatigue in practice. A first step towards building such an interface is to quantify fatigue, and more importantly, to quantify it easily. While there have been methods developed to estimate arm fatigue in mid-air interaction, there remains little understanding of fatigue on touch-based interfaces. To address this gap, we propose that existing models for mid-air interaction may be effective for measuring fatigue on large multi-touch displays. We evaluated the accuracy of Jang et al.'s mid-air Cumulative Fatigue model for touch interaction tasks on a large display. We found that their model underestimates subjective fatigue for multi-touch interaction, but can provide accurate estimates of subjective fatigue after fine-tuning of model parameters. We discuss the implications of this finding, and the need to further develop tools to evaluate fatigue on large, multi-touch displays."],"dc:identifier.uri":["http://hdl.handle.net/10012/14972"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:subject":["Fatigue","Large Display","Multi-touch"],"dc:title":["Modeling Cumulative Arm Fatigue on Large Multi-touch Displays"],"dc:type":["Master Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:54:28Z"}