{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/15297"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/15297","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"Strategic design of flow structures for single (bio) particle analysis using droplet microfluidic platform","abstract":"This thesis is designed to meet the need for knowledge of droplet-based encapsulation strategies by carrying out systematic fundamental studies based on a double-cross configuration. This configuration has been commonly used for co-encapsulation of particles or cells with multiple reagents. Particular attention is also paid to the simplicity and robustness of the channel network for real-world applications. Proposed methods of single-particle encapsulation and integration of multiple functional components are validated by the first two projects. The goal of the first project is to co-encapsulate a 1micrometer magnetic bead (MB) with multiple Quantum Dots (QDs) for further bio-decorating the QD surfaces with different molecules (i.e. single-strand DNA). The goal of the second project is to integrate into a single device a two-step reaction assay for functionalizing the surface of QDs with oligonucleotide strands while QDs are immobilized on MBs. The QD-Oligonucleotide conjugate serves as bio-sensing probes for nucleic acid detection. Additionally, to provide the fundamental knowledge for non-microfluidic-researchers to apply this approach in their single-encapsulation applications, a comprehensive experimental study is designed to span a wide range of operating parameters.","abstract_html":"This thesis is designed to meet the need for knowledge of droplet-based encapsulation strategies by carrying out systematic fundamental studies based on a double-cross configuration. This configuration has been commonly used for co-encapsulation of particles or cells with multiple reagents. Particular attention is also paid to the simplicity and robustness of the channel network for real-world applications. Proposed methods of single-particle encapsulation and integration of multiple functional components are validated by the first two projects. The goal of the first project is to co-encapsulate a 1micrometer magnetic bead (MB) with multiple Quantum Dots (QDs) for further bio-decorating the QD surfaces with different molecules (i.e. single-strand DNA). The goal of the second project is to integrate into a single device a two-step reaction assay for functionalizing the surface of QDs with oligonucleotide strands while QDs are immobilized on MBs. The QD-Oligonucleotide conjugate serves as bio-sensing probes for nucleic acid detection. Additionally, to provide the fundamental knowledge for non-microfluidic-researchers to apply this approach in their single-encapsulation applications, a comprehensive experimental study is designed to span a wide range of operating parameters.","abstract_has_math":false,"creators":["Nguyen, Hoang Anh Thu"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Ren, Carolyn"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-12-10","date_published":"2019-12-10","updated_at":"2026-11-19T09:40:33Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10012/15297","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10012/15297","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Awaterloo%3Aoai%3Auwspace.uwaterloo.ca%3A10012%2F15297","prefix":"oai_dc"},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F15297","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ren, Carolyn"]},{"key":"dc:creator","label":"Author","values":["Nguyen, Hoang Anh Thu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-12-10T20:33:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-12-10T20:33:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-12-10"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2019-12-02"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10012/15297"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis is designed to meet the need for knowledge of droplet-based encapsulation strategies by carrying out systematic fundamental studies based on a double-cross configuration. This configuration has been commonly used for co-encapsulation of particles or cells with multiple reagents. Particular attention is also paid to the simplicity and robustness of the channel network for real-world applications. Proposed methods of single-particle encapsulation and integration of multiple functional components are validated by the first two projects. The goal of the first project is to co-encapsulate a 1micrometer magnetic bead (MB) with multiple Quantum Dots (QDs) for further bio-decorating the QD surfaces with different molecules (i.e. single-strand DNA). The goal of the second project is to integrate into a single device a two-step reaction assay for functionalizing the surface of QDs with oligonucleotide strands while QDs are immobilized on MBs. The QD-Oligonucleotide conjugate serves as bio-sensing probes for nucleic acid detection. Additionally, to provide the fundamental knowledge for non-microfluidic-researchers to apply this approach in their single-encapsulation applications, a comprehensive experimental study is designed to span a wide range of operating parameters."]},{"key":"dc:title","label":"Title","values":["Strategic design of flow structures for single (bio) particle analysis using droplet microfluidic platform"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ren, Carolyn"],"dc:creator":["Nguyen, Hoang Anh Thu"],"dc:date.accessioned":["2019-12-10T20:33:13Z"],"dc:date.available":["2019-12-10T20:33:13Z"],"dc:date.issued":["2019-12-10"],"dc:date.submitted":["2019-12-02"],"dc:description.abstract":["This thesis is designed to meet the need for knowledge of droplet-based encapsulation strategies by carrying out systematic fundamental studies based on a double-cross configuration. This configuration has been commonly used for co-encapsulation of particles or cells with multiple reagents. Particular attention is also paid to the simplicity and robustness of the channel network for real-world applications. Proposed methods of single-particle encapsulation and integration of multiple functional components are validated by the first two projects. The goal of the first project is to co-encapsulate a 1micrometer magnetic bead (MB) with multiple Quantum Dots (QDs) for further bio-decorating the QD surfaces with different molecules (i.e. single-strand DNA). The goal of the second project is to integrate into a single device a two-step reaction assay for functionalizing the surface of QDs with oligonucleotide strands while QDs are immobilized on MBs. The QD-Oligonucleotide conjugate serves as bio-sensing probes for nucleic acid detection. Additionally, to provide the fundamental knowledge for non-microfluidic-researchers to apply this approach in their single-encapsulation applications, a comprehensive experimental study is designed to span a wide range of operating parameters."],"dc:identifier.uri":["http://hdl.handle.net/10012/15297"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:title":["Strategic design of flow structures for single (bio) particle analysis using droplet microfluidic platform"],"dc:type":["Doctoral Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:40:33Z"}