{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/15694"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/15694","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"Compensated Row-Column Ultrasound Imaging System","abstract":"Ultrasound imaging is a valuable tool in many applications ranging from material science to medical imaging. While 2-D ultrasound imaging is more commonly used, 3-D ultrasound imaging offers unique opportunities that can only be found with the help of the extra dimension. Acquiring a 3-D ultrasound image can be done in two main ways: mechanically moving a transducer over a region of interest and using a fixed 2-D transducer. Mechanical motion introduces unwanted artifacts and increases image acquisition time, so a fixed 2-D is usually preferred. However, a fully addressed 2-D array will require a significant amount of connections and data to handle. This motivated the exploration of different simplification schemes to make 2-D arrays for 3-D ultrasound imaging feasible. A method that received a lot of attention for making real-time volumetric ultrasound imaging possible is the row-column method. The row-column method simplifies the fully addressed 2-D array by utilizing a set of 1-D arrays arranged in rows and another set in columns, one set will be responsible for transmit beamforming, while the other for receive beamforming. Using this setup, only $N+N$ connections are needed instead of $N\\times N$. This simplification comes at the cost of image quality. Recent advances in row-column ultrasound imaging systems were largely focused on transducer design. However, these imaging systems face a few intrinsic challenges which cannot be addressed through transducer design alone: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account. As such, strategies for tackling these intrinsic challenges in row-column imaging would be highly desired to improve imaging quality. In this thesis, we propose a novel compensated row-column ultrasound imaging system where the intrinsic characteristics of the transducer and other aspects of the physical row-column imaging apparatus are leveraged to computationally produce high quality ultrasound imagery. More specifically, the proposed system incorporates a novel conditional random field-driven computational image reconstruction component consisting of two phases: i) characterization and ii) compensation. In the characterization phase, a joint statistical image formation and noise model is introduced for characterizing the intrinsic properties of the physical row-column ultrasound imaging system. In the compensation phase, the developed joint image formation and noise model is incorporated alongside a conditional random field model within an energy minimization framework to reconstruct the compensated row-column ultrasound imagery. To explore the efficacy of the proposed concept, we introduced three different realizations of the proposed compensated row-column ultrasound imaging system. First, we introduce a compensated row-column imaging system based on a novel multilayered conditional random field driven framework to better account for local spatial relationships in the captured data. Second, we incorporated more global relationships by introducing a compensated row-column imaging system based around a novel edge-guided stochastically fully connected random field framework. Third, accounting for the case where the analytical image formation model may not optimally reflect the real-world physical system, we introduce a compensated row-column imaging system based around a data-driven spatially varying point-spread-function learning framework to better characterize the true physical image formation characteristics. While these different realizations of the compensated row-column system have their advantages and disadvantages, which will be discussed throughout this thesis, they all manage to boost the performance of the row-column method to comparable and often higher levels than the fully addressed 2-D array.","abstract_html":"Ultrasound imaging is a valuable tool in many applications ranging from material science to medical imaging. While 2-D ultrasound imaging is more commonly used, 3-D ultrasound imaging offers unique opportunities that can only be found with the help of the extra dimension. Acquiring a 3-D ultrasound image can be done in two main ways: mechanically moving a transducer over a region of interest and using a fixed 2-D transducer. Mechanical motion introduces unwanted artifacts and increases image acquisition time, so a fixed 2-D is usually preferred. However, a fully addressed 2-D array will require a significant amount of connections and data to handle. This motivated the exploration of different simplification schemes to make 2-D arrays for 3-D ultrasound imaging feasible. A method that received a lot of attention for making real-time volumetric ultrasound imaging possible is the row-column method. The row-column method simplifies the fully addressed 2-D array by utilizing a set of 1-D arrays arranged in rows and another set in columns, one set will be responsible for transmit beamforming, while the other for receive beamforming. Using this setup, only $N+N$ connections are needed instead of $N\\times N$. This simplification comes at the cost of image quality. Recent advances in row-column ultrasound imaging systems were largely focused on transducer design. However, these imaging systems face a few intrinsic challenges which cannot be addressed through transducer design alone: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account. As such, strategies for tackling these intrinsic challenges in row-column imaging would be highly desired to improve imaging quality. In this thesis, we propose a novel compensated row-column ultrasound imaging system where the intrinsic characteristics of the transducer and other aspects of the physical row-column imaging apparatus are leveraged to computationally produce high quality ultrasound imagery. More specifically, the proposed system incorporates a novel conditional random field-driven computational image reconstruction component consisting of two phases: i) characterization and ii) compensation. In the characterization phase, a joint statistical image formation and noise model is introduced for characterizing the intrinsic properties of the physical row-column ultrasound imaging system. In the compensation phase, the developed joint image formation and noise model is incorporated alongside a conditional random field model within an energy minimization framework to reconstruct the compensated row-column ultrasound imagery. To explore the efficacy of the proposed concept, we introduced three different realizations of the proposed compensated row-column ultrasound imaging system. First, we introduce a compensated row-column imaging system based on a novel multilayered conditional random field driven framework to better account for local spatial relationships in the captured data. Second, we incorporated more global relationships by introducing a compensated row-column imaging system based around a novel edge-guided stochastically fully connected random field framework. Third, accounting for the case where the analytical image formation model may not optimally reflect the real-world physical system, we introduce a compensated row-column imaging system based around a data-driven spatially varying point-spread-function learning framework to better characterize the true physical image formation characteristics. While these different realizations of the compensated row-column system have their advantages and disadvantages, which will be discussed throughout this thesis, they all manage to boost the performance of the row-column method to comparable and often higher levels than the fully addressed 2-D array.","abstract_has_math":true,"creators":["Ben Daya, Ibrahim"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Wong, Alexander","Yeow, John"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-03-12","date_published":"2020-03-12","updated_at":"2026-11-19T10:47:17Z","subjects":["Conditional Random Fields","Row-column","ultrasound imaging","compensated imaging","point spread function modelling","point spread function learning","Ultrasonic imaging"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10012/15694","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10012/15694","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Awaterloo%3Aoai%3Auwspace.uwaterloo.ca%3A10012%2F15694","prefix":"oai_dc"},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F15694","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wong, Alexander","Yeow, John"]},{"key":"dc:creator","label":"Author","values":["Ben Daya, Ibrahim"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-03-12T19:29:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-03-12T19:29:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-03-12"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2020-03-11"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Conditional Random Fields","Row-column","ultrasound imaging","compensated imaging","point spread function modelling","point spread function learning"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Ultrasonic imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10012/15694"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ultrasound imaging is a valuable tool in many applications ranging from material science to medical imaging. While 2-D ultrasound imaging is more commonly used, 3-D ultrasound imaging offers unique opportunities that can only be found with the help of the extra dimension. Acquiring a 3-D ultrasound image can be done in two main ways: mechanically moving a transducer over a region of interest and using a fixed 2-D transducer. Mechanical motion introduces unwanted artifacts and increases image acquisition time, so a fixed 2-D is usually preferred. However, a fully addressed 2-D array will require a significant amount of connections and data to handle. This motivated the exploration of different simplification schemes to make 2-D arrays for 3-D ultrasound imaging feasible. A method that received a lot of attention for making real-time volumetric ultrasound imaging possible is the row-column method. The row-column method simplifies the fully addressed 2-D array by utilizing a set of 1-D arrays arranged in rows and another set in columns, one set will be responsible for transmit beamforming, while the other for receive beamforming. Using this setup, only $N+N$ connections are needed instead of $N\\times N$. This simplification comes at the cost of image quality. Recent advances in row-column ultrasound imaging systems were largely focused on transducer design. However, these imaging systems face a few intrinsic challenges which cannot be addressed through transducer design alone: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account. As such, strategies for tackling these intrinsic challenges in row-column imaging would be highly desired to improve imaging quality. In this thesis, we propose a novel compensated row-column ultrasound imaging system where the intrinsic characteristics of the transducer and other aspects of the physical row-column imaging apparatus are leveraged to computationally produce high quality ultrasound imagery. More specifically, the proposed system incorporates a novel conditional random field-driven computational image reconstruction component consisting of two phases: i) characterization and ii) compensation. In the characterization phase, a joint statistical image formation and noise model is introduced for characterizing the intrinsic properties of the physical row-column ultrasound imaging system. In the compensation phase, the developed joint image formation and noise model is incorporated alongside a conditional random field model within an energy minimization framework to reconstruct the compensated row-column ultrasound imagery. To explore the efficacy of the proposed concept, we introduced three different realizations of the proposed compensated row-column ultrasound imaging system. First, we introduce a compensated row-column imaging system based on a novel multilayered conditional random field driven framework to better account for local spatial relationships in the captured data. Second, we incorporated more global relationships by introducing a compensated row-column imaging system based around a novel edge-guided stochastically fully connected random field framework. Third, accounting for the case where the analytical image formation model may not optimally reflect the real-world physical system, we introduce a compensated row-column imaging system based around a data-driven spatially varying point-spread-function learning framework to better characterize the true physical image formation characteristics. While these different realizations of the compensated row-column system have their advantages and disadvantages, which will be discussed throughout this thesis, they all manage to boost the performance of the row-column method to comparable and often higher levels than the fully addressed 2-D array."]},{"key":"dc:title","label":"Title","values":["Compensated Row-Column Ultrasound Imaging System"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wong, Alexander","Yeow, John"],"dc:creator":["Ben Daya, Ibrahim"],"dc:date.accessioned":["2020-03-12T19:29:20Z"],"dc:date.available":["2020-03-12T19:29:20Z"],"dc:date.issued":["2020-03-12"],"dc:date.submitted":["2020-03-11"],"dc:description.abstract":["Ultrasound imaging is a valuable tool in many applications ranging from material science to medical imaging. While 2-D ultrasound imaging is more commonly used, 3-D ultrasound imaging offers unique opportunities that can only be found with the help of the extra dimension. Acquiring a 3-D ultrasound image can be done in two main ways: mechanically moving a transducer over a region of interest and using a fixed 2-D transducer. Mechanical motion introduces unwanted artifacts and increases image acquisition time, so a fixed 2-D is usually preferred. However, a fully addressed 2-D array will require a significant amount of connections and data to handle. This motivated the exploration of different simplification schemes to make 2-D arrays for 3-D ultrasound imaging feasible. A method that received a lot of attention for making real-time volumetric ultrasound imaging possible is the row-column method. The row-column method simplifies the fully addressed 2-D array by utilizing a set of 1-D arrays arranged in rows and another set in columns, one set will be responsible for transmit beamforming, while the other for receive beamforming. Using this setup, only $N+N$ connections are needed instead of $N\\times N$. This simplification comes at the cost of image quality. Recent advances in row-column ultrasound imaging systems were largely focused on transducer design. However, these imaging systems face a few intrinsic challenges which cannot be addressed through transducer design alone: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account. As such, strategies for tackling these intrinsic challenges in row-column imaging would be highly desired to improve imaging quality. In this thesis, we propose a novel compensated row-column ultrasound imaging system where the intrinsic characteristics of the transducer and other aspects of the physical row-column imaging apparatus are leveraged to computationally produce high quality ultrasound imagery. More specifically, the proposed system incorporates a novel conditional random field-driven computational image reconstruction component consisting of two phases: i) characterization and ii) compensation. In the characterization phase, a joint statistical image formation and noise model is introduced for characterizing the intrinsic properties of the physical row-column ultrasound imaging system. In the compensation phase, the developed joint image formation and noise model is incorporated alongside a conditional random field model within an energy minimization framework to reconstruct the compensated row-column ultrasound imagery. To explore the efficacy of the proposed concept, we introduced three different realizations of the proposed compensated row-column ultrasound imaging system. First, we introduce a compensated row-column imaging system based on a novel multilayered conditional random field driven framework to better account for local spatial relationships in the captured data. Second, we incorporated more global relationships by introducing a compensated row-column imaging system based around a novel edge-guided stochastically fully connected random field framework. Third, accounting for the case where the analytical image formation model may not optimally reflect the real-world physical system, we introduce a compensated row-column imaging system based around a data-driven spatially varying point-spread-function learning framework to better characterize the true physical image formation characteristics. While these different realizations of the compensated row-column system have their advantages and disadvantages, which will be discussed throughout this thesis, they all manage to boost the performance of the row-column method to comparable and often higher levels than the fully addressed 2-D array."],"dc:identifier.uri":["http://hdl.handle.net/10012/15694"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:subject":["Conditional Random Fields","Row-column","ultrasound imaging","compensated imaging","point spread function modelling","point spread function learning"],"dc:subject.lcsh":["Ultrasonic imaging"],"dc:title":["Compensated Row-Column Ultrasound Imaging System"],"dc:type":["Doctoral Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:47:17Z"}