{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/18083"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/18083","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"Oscillator-Based Electrochemical Capacitance Imager with Frequency-Division-Multiplexed Readout","abstract":"Electrochemical biosensors, built using complimentary-metal-oxide semiconductor (CMOS) technology, have shown promise for various applications in health-care diagnostics, disease detection, and life science research. Unlike traditional bench-top instrumentation, CMOS-based platforms offer large-scale integration of sensor pixel arrays and readout electronics on the same chip, yielding improved spatial resolution, throughput, and signal-to-noise ratio (SNR) compared to non-integrated systems. In this thesis, we present the design and electronic characterization of a CMOS oscillator- based electrochemical capacitance imager for biosensing. The imager features both time- division multiplexed (TDM) and frequency-division-multiplexed (FDM) readout, and is suitable for overcoming Debye-length-screening effects in integrated electrochemical biosensors. The implementation of FDM readout enables improved frame rate or improved signal-to-noise ratio (SNR) when compared to an imager that employs standard TDM readout. Each pixel in the array contains a 5-MHz–180-MHz capacitance-to-frequency converter (CFC) to detect changes in the interfacial capacitance at an in-pixel working electrode, ranging in area from 2×2-µm 2 to 200×200-µm 2. We report experimental results from electronic characterization of a 420-pixel, 3.0×2.5 mm 2 capacitance imager, fabricated in a 1.8-V, 0.18-µm mixed-signal CMOS process. To the best of our knowledge, our work is the first demonstration of a CFC-based CMOS capacitance imager for biosensing with both TDM and FDM readout.","abstract_html":"Electrochemical biosensors, built using complimentary-metal-oxide semiconductor (CMOS) technology, have shown promise for various applications in health-care diagnostics, disease detection, and life science research. Unlike traditional bench-top instrumentation, CMOS-based platforms offer large-scale integration of sensor pixel arrays and readout electronics on the same chip, yielding improved spatial resolution, throughput, and signal-to-noise ratio (SNR) compared to non-integrated systems. In this thesis, we present the design and electronic characterization of a CMOS oscillator- based electrochemical capacitance imager for biosensing. The imager features both time- division multiplexed (TDM) and frequency-division-multiplexed (FDM) readout, and is suitable for overcoming Debye-length-screening effects in integrated electrochemical biosensors. The implementation of FDM readout enables improved frame rate or improved signal-to-noise ratio (SNR) when compared to an imager that employs standard TDM readout. Each pixel in the array contains a 5-MHz–180-MHz capacitance-to-frequency converter (CFC) to detect changes in the interfacial capacitance at an in-pixel working electrode, ranging in area from 2×2-µm 2 to 200×200-µm 2. We report experimental results from electronic characterization of a 420-pixel, 3.0×2.5 mm 2 capacitance imager, fabricated in a 1.8-V, 0.18-µm mixed-signal CMOS process. To the best of our knowledge, our work is the first demonstration of a CFC-based CMOS capacitance imager for biosensing with both TDM and FDM readout.","abstract_has_math":false,"creators":["Krishnan, Ashwin"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Levine, Peter"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-02-24","date_published":"2022-02-24","updated_at":"2026-11-19T10:50:35Z","subjects":["electrochemical","biosensor","chip design","electrical","frequency-division-multiplexing","CMOS"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10012/18083","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10012/18083","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F18083","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Levine, Peter"]},{"key":"dc:creator","label":"Author","values":["Krishnan, Ashwin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-02-24T15:11:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-02-25T05:50:04Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-02-24"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2022-02-18"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["electrochemical","biosensor","chip design","electrical","frequency-division-multiplexing","CMOS"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10012/18083"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Electrochemical biosensors, built using complimentary-metal-oxide semiconductor (CMOS) technology, have shown promise for various applications in health-care diagnostics, disease detection, and life science research. Unlike traditional bench-top instrumentation, CMOS-based platforms offer large-scale integration of sensor pixel arrays and readout electronics on the same chip, yielding improved spatial resolution, throughput, and signal-to-noise ratio (SNR) compared to non-integrated systems. In this thesis, we present the design and electronic characterization of a CMOS oscillator- based electrochemical capacitance imager for biosensing. The imager features both time- division multiplexed (TDM) and frequency-division-multiplexed (FDM) readout, and is suitable for overcoming Debye-length-screening effects in integrated electrochemical biosensors. The implementation of FDM readout enables improved frame rate or improved signal-to-noise ratio (SNR) when compared to an imager that employs standard TDM readout. Each pixel in the array contains a 5-MHz–180-MHz capacitance-to-frequency converter (CFC) to detect changes in the interfacial capacitance at an in-pixel working electrode, ranging in area from 2×2-µm 2 to 200×200-µm 2. We report experimental results from electronic characterization of a 420-pixel, 3.0×2.5 mm 2 capacitance imager, fabricated in a 1.8-V, 0.18-µm mixed-signal CMOS process. To the best of our knowledge, our work is the first demonstration of a CFC-based CMOS capacitance imager for biosensing with both TDM and FDM readout."]},{"key":"dc:title","label":"Title","values":["Oscillator-Based Electrochemical Capacitance Imager with Frequency-Division-Multiplexed Readout"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Levine, Peter"],"dc:creator":["Krishnan, Ashwin"],"dc:date.accessioned":["2022-02-24T15:11:28Z"],"dc:date.available":["2024-02-25T05:50:04Z"],"dc:date.issued":["2022-02-24"],"dc:date.submitted":["2022-02-18"],"dc:description.abstract":["Electrochemical biosensors, built using complimentary-metal-oxide semiconductor (CMOS) technology, have shown promise for various applications in health-care diagnostics, disease detection, and life science research. Unlike traditional bench-top instrumentation, CMOS-based platforms offer large-scale integration of sensor pixel arrays and readout electronics on the same chip, yielding improved spatial resolution, throughput, and signal-to-noise ratio (SNR) compared to non-integrated systems. In this thesis, we present the design and electronic characterization of a CMOS oscillator- based electrochemical capacitance imager for biosensing. The imager features both time- division multiplexed (TDM) and frequency-division-multiplexed (FDM) readout, and is suitable for overcoming Debye-length-screening effects in integrated electrochemical biosensors. The implementation of FDM readout enables improved frame rate or improved signal-to-noise ratio (SNR) when compared to an imager that employs standard TDM readout. Each pixel in the array contains a 5-MHz–180-MHz capacitance-to-frequency converter (CFC) to detect changes in the interfacial capacitance at an in-pixel working electrode, ranging in area from 2×2-µm 2 to 200×200-µm 2. We report experimental results from electronic characterization of a 420-pixel, 3.0×2.5 mm 2 capacitance imager, fabricated in a 1.8-V, 0.18-µm mixed-signal CMOS process. To the best of our knowledge, our work is the first demonstration of a CFC-based CMOS capacitance imager for biosensing with both TDM and FDM readout."],"dc:identifier.uri":["http://hdl.handle.net/10012/18083"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:subject":["electrochemical","biosensor","chip design","electrical","frequency-division-multiplexing","CMOS"],"dc:title":["Oscillator-Based Electrochemical Capacitance Imager with Frequency-Division-Multiplexed Readout"],"dc:type":["Master Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:50:35Z"}