{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/23361"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/23361","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"A Low-Power Wireless Transmitter for a Continuous Glucose Monitoring System-on-Chip","abstract":"Continuous glucose monitoring (CGM) can improve diabetes management by providing frequent measurements and revealing trends that are difficult to capture with invasive, intermittent tests. To this end, a miniaturized, wearable sensing platform that operates continuously and delivers timely alerts is beneficial for individuals who require active glucose management. This thesis presents a wireless transmitter, implemented in a complementary metal-oxide-semiconductor (CMOS) integrated circuit technology, for energy-efficient telemetry of biomedical signals from a wearable device that transmits short packets to a smartphone, enabling practical daily readout. Since the transmitter must meet Bluetooth Low Energy (BLE) constraints under a tight energy budget, several circuit and system-level design choices that balance frequency accuracy, spectral compliance, and robustness to process-voltage-temperature (PVT) variation at low supply voltages must be made. The proposed wireless transmitter is one component of a larger mixed-signal system-on-chip (SoC), which integrates a commercially-available electrochemical sensor that interacts with glucose and/or ketones, to enable continuous concentration measurement. The sensing front-end electronics of the SoC converts chemical activity into an electrical signal that is conditioned and digitized on-chip. This measured concentration is then encoded for BLE-compatible transmission by modulating the digitized data using Gaussian frequency-shift keying (GFSK) in the 2.4 GHz industrial, scientific, and medical (ISM) band, implemented as an integer-N charge-pump phase-locked loop (CP-PLL) with direct voltage-controlled oscillator (VCO) modulation. Simulated and experimental results from a fabricated prototype chip demonstrate the feasibility of the proposed approach in terms of sensor readout, burst energy, and BLE spectral compliance. Implemented in a 0.18 µm bulk CMOS process, the fabricated transmitter delivers -7.06 dBm at 13.5 mW DC power, with an intra-packet drift of 41.56 kHz and reference spurs of −26.4 dBm at ±2 MHz offsets — both within BLE LE 1M limits. End-to-end validation confirms the successful reception of BLE advertising packets on a commodity Nordic nRF5340 receiver, with the digitized electrochemical sensor data reconstructed from over-the-air stream. The presented methodology provides a foundation for compact wearable bio-sensing platforms, combining continuous chemical sensing with standardized wireless communication for patient-facing monitoring and alerts.","abstract_html":"Continuous glucose monitoring (CGM) can improve diabetes management by providing frequent measurements and revealing trends that are difficult to capture with invasive, intermittent tests. To this end, a miniaturized, wearable sensing platform that operates continuously and delivers timely alerts is beneficial for individuals who require active glucose management. This thesis presents a wireless transmitter, implemented in a complementary metal-oxide-semiconductor (CMOS) integrated circuit technology, for energy-efficient telemetry of biomedical signals from a wearable device that transmits short packets to a smartphone, enabling practical daily readout. Since the transmitter must meet Bluetooth Low Energy (BLE) constraints under a tight energy budget, several circuit and system-level design choices that balance frequency accuracy, spectral compliance, and robustness to process-voltage-temperature (PVT) variation at low supply voltages must be made. The proposed wireless transmitter is one component of a larger mixed-signal system-on-chip (SoC), which integrates a commercially-available electrochemical sensor that interacts with glucose and/or ketones, to enable continuous concentration measurement. The sensing front-end electronics of the SoC converts chemical activity into an electrical signal that is conditioned and digitized on-chip. This measured concentration is then encoded for BLE-compatible transmission by modulating the digitized data using Gaussian frequency-shift keying (GFSK) in the 2.4 GHz industrial, scientific, and medical (ISM) band, implemented as an integer-N charge-pump phase-locked loop (CP-PLL) with direct voltage-controlled oscillator (VCO) modulation. Simulated and experimental results from a fabricated prototype chip demonstrate the feasibility of the proposed approach in terms of sensor readout, burst energy, and BLE spectral compliance. Implemented in a 0.18 µm bulk CMOS process, the fabricated transmitter delivers -7.06 dBm at 13.5 mW DC power, with an intra-packet drift of 41.56 kHz and reference spurs of −26.4 dBm at ±2 MHz offsets — both within BLE LE 1M limits. End-to-end validation confirms the successful reception of BLE advertising packets on a commodity Nordic nRF5340 receiver, with the digitized electrochemical sensor data reconstructed from over-the-air stream. The presented methodology provides a foundation for compact wearable bio-sensing platforms, combining continuous chemical sensing with standardized wireless communication for patient-facing monitoring and alerts.","abstract_has_math":false,"creators":["Loka, Rino"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-05-21","date_published":"2026-05-21","updated_at":"2026-11-19T10:52:15Z","subjects":["ble advertising cmos transmitter","bluetooth low power","continuous glucose mentoring (CGM)","integer-N pll for BLE"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10012/23361","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10012/23361","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F23361","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Loka, Rino"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-05-21T13:31:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-05-21T13:31:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-05-21"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2026-05-06"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ble advertising cmos transmitter","bluetooth low power","continuous glucose mentoring (CGM)","integer-N pll for BLE"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10012/23361"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Continuous glucose monitoring (CGM) can improve diabetes management by providing frequent measurements and revealing trends that are difficult to capture with invasive, intermittent tests. To this end, a miniaturized, wearable sensing platform that operates continuously and delivers timely alerts is beneficial for individuals who require active glucose management. This thesis presents a wireless transmitter, implemented in a complementary metal-oxide-semiconductor (CMOS) integrated circuit technology, for energy-efficient telemetry of biomedical signals from a wearable device that transmits short packets to a smartphone, enabling practical daily readout. Since the transmitter must meet Bluetooth Low Energy (BLE) constraints under a tight energy budget, several circuit and system-level design choices that balance frequency accuracy, spectral compliance, and robustness to process-voltage-temperature (PVT) variation at low supply voltages must be made. The proposed wireless transmitter is one component of a larger mixed-signal system-on-chip (SoC), which integrates a commercially-available electrochemical sensor that interacts with glucose and/or ketones, to enable continuous concentration measurement. The sensing front-end electronics of the SoC converts chemical activity into an electrical signal that is conditioned and digitized on-chip. This measured concentration is then encoded for BLE-compatible transmission by modulating the digitized data using Gaussian frequency-shift keying (GFSK) in the 2.4 GHz industrial, scientific, and medical (ISM) band, implemented as an integer-N charge-pump phase-locked loop (CP-PLL) with direct voltage-controlled oscillator (VCO) modulation. Simulated and experimental results from a fabricated prototype chip demonstrate the feasibility of the proposed approach in terms of sensor readout, burst energy, and BLE spectral compliance. Implemented in a 0.18 µm bulk CMOS process, the fabricated transmitter delivers -7.06 dBm at 13.5 mW DC power, with an intra-packet drift of 41.56 kHz and reference spurs of −26.4 dBm at ±2 MHz offsets — both within BLE LE 1M limits. End-to-end validation confirms the successful reception of BLE advertising packets on a commodity Nordic nRF5340 receiver, with the digitized electrochemical sensor data reconstructed from over-the-air stream. The presented methodology provides a foundation for compact wearable bio-sensing platforms, combining continuous chemical sensing with standardized wireless communication for patient-facing monitoring and alerts."]},{"key":"dc:title","label":"Title","values":["A Low-Power Wireless Transmitter for a Continuous Glucose Monitoring System-on-Chip"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:creator":["Loka, Rino"],"dc:date.accessioned":["2026-05-21T13:31:19Z"],"dc:date.available":["2026-05-21T13:31:19Z"],"dc:date.issued":["2026-05-21"],"dc:date.submitted":["2026-05-06"],"dc:description.abstract":["Continuous glucose monitoring (CGM) can improve diabetes management by providing frequent measurements and revealing trends that are difficult to capture with invasive, intermittent tests. To this end, a miniaturized, wearable sensing platform that operates continuously and delivers timely alerts is beneficial for individuals who require active glucose management. This thesis presents a wireless transmitter, implemented in a complementary metal-oxide-semiconductor (CMOS) integrated circuit technology, for energy-efficient telemetry of biomedical signals from a wearable device that transmits short packets to a smartphone, enabling practical daily readout. Since the transmitter must meet Bluetooth Low Energy (BLE) constraints under a tight energy budget, several circuit and system-level design choices that balance frequency accuracy, spectral compliance, and robustness to process-voltage-temperature (PVT) variation at low supply voltages must be made. The proposed wireless transmitter is one component of a larger mixed-signal system-on-chip (SoC), which integrates a commercially-available electrochemical sensor that interacts with glucose and/or ketones, to enable continuous concentration measurement. The sensing front-end electronics of the SoC converts chemical activity into an electrical signal that is conditioned and digitized on-chip. This measured concentration is then encoded for BLE-compatible transmission by modulating the digitized data using Gaussian frequency-shift keying (GFSK) in the 2.4 GHz industrial, scientific, and medical (ISM) band, implemented as an integer-N charge-pump phase-locked loop (CP-PLL) with direct voltage-controlled oscillator (VCO) modulation. Simulated and experimental results from a fabricated prototype chip demonstrate the feasibility of the proposed approach in terms of sensor readout, burst energy, and BLE spectral compliance. Implemented in a 0.18 µm bulk CMOS process, the fabricated transmitter delivers -7.06 dBm at 13.5 mW DC power, with an intra-packet drift of 41.56 kHz and reference spurs of −26.4 dBm at ±2 MHz offsets — both within BLE LE 1M limits. End-to-end validation confirms the successful reception of BLE advertising packets on a commodity Nordic nRF5340 receiver, with the digitized electrochemical sensor data reconstructed from over-the-air stream. The presented methodology provides a foundation for compact wearable bio-sensing platforms, combining continuous chemical sensing with standardized wireless communication for patient-facing monitoring and alerts."],"dc:identifier.uri":["https://hdl.handle.net/10012/23361"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:subject":["ble advertising cmos transmitter","bluetooth low power","continuous glucose mentoring (CGM)","integer-N pll for BLE"],"dc:title":["A Low-Power Wireless Transmitter for a Continuous Glucose Monitoring System-on-Chip"],"dc:type":["Master Thesis"],"others:access_status":["embargo"]},"updated_at":"2026-11-19T10:52:15Z"}