{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/23384"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/23384","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"A High-Resolution Frequency-Division-Multiplexed Single-Photon-Counting CMOS X-Ray Imager","abstract":"Spectral X-ray imaging based on single photon counting (SPC) has clear benefits for reducing radiation dose and improving tissue contrast in medical imaging. However, fitting the spectral readout electronics into a small pixel area in order to provide high spatial resolution is still challenging in readout integrated circuit (ROIC) design. This thesis covers the modeling, design, and measurement of a CMOS SPC X-ray imager intended for mammography and computed tomography (CT) that implements, for the first time, frequency-division multiplexed (FDM) readout to achieve high spatial resolution. Reducing pixel dimensions to 50 x 50 µm² is critical to leveraging the \"small-pixel effect\", which is a phenomenon that minimizes the impact of slow charge trapping in some X-ray sensors to drastically improve energy resolution. However, this stringent area constraint renders conventional per-pixel digitization architectures impractical. The proposed architecture, therefore, uses FDM, which allows the analog-to-digital converter (ADC) to be moved outside the pixel so that one ADC can serve an entire column of pixels. This architectural change helps mitigate the area and count-rate limitations inherent in X-ray imagers with in-pixel ADCs. In our proposed ROIC, each pixel contains a charge-sensitive amplifier (CSA) followed by a CR-RC shaper, which then feeds a mixer driven by a local oscillator. The shaped pulses are modulated onto orthogonal carrier frequencies, summed using a transimpedance amplifier (TIA), and then digitized by a shared 8-bit 200 MHz pipelined ADC. Measurements from our ROIC, fabricated in a 1.8-V 180-nm CMOS process, confirm that our proposed multi-carrier FDM readout scheme functions as intended. The ADC achieves a 7.28 bit effective number of bits (ENOB), providing a theoretical maximum of 176 distinct energy bins. In addition the average equivalent noise charge (ENC) is measured to be 96 e- per pixel, and 306 e- per column. Our experimental results demonstrate that FDM is a viable approach for spectral X-ray imaging and point toward a scalable path for future high-resolution SPC imagers.","abstract_html":"Spectral X-ray imaging based on single photon counting (SPC) has clear benefits for reducing radiation dose and improving tissue contrast in medical imaging. However, fitting the spectral readout electronics into a small pixel area in order to provide high spatial resolution is still challenging in readout integrated circuit (ROIC) design. This thesis covers the modeling, design, and measurement of a CMOS SPC X-ray imager intended for mammography and computed tomography (CT) that implements, for the first time, frequency-division multiplexed (FDM) readout to achieve high spatial resolution. Reducing pixel dimensions to 50 x 50 µm² is critical to leveraging the &quot;small-pixel effect&quot;, which is a phenomenon that minimizes the impact of slow charge trapping in some X-ray sensors to drastically improve energy resolution. However, this stringent area constraint renders conventional per-pixel digitization architectures impractical. The proposed architecture, therefore, uses FDM, which allows the analog-to-digital converter (ADC) to be moved outside the pixel so that one ADC can serve an entire column of pixels. This architectural change helps mitigate the area and count-rate limitations inherent in X-ray imagers with in-pixel ADCs. In our proposed ROIC, each pixel contains a charge-sensitive amplifier (CSA) followed by a CR-RC shaper, which then feeds a mixer driven by a local oscillator. The shaped pulses are modulated onto orthogonal carrier frequencies, summed using a transimpedance amplifier (TIA), and then digitized by a shared 8-bit 200 MHz pipelined ADC. Measurements from our ROIC, fabricated in a 1.8-V 180-nm CMOS process, confirm that our proposed multi-carrier FDM readout scheme functions as intended. The ADC achieves a 7.28 bit effective number of bits (ENOB), providing a theoretical maximum of 176 distinct energy bins. In addition the average equivalent noise charge (ENC) is measured to be 96 e- per pixel, and 306 e- per column. Our experimental results demonstrate that FDM is a viable approach for spectral X-ray imaging and point toward a scalable path for future high-resolution SPC imagers.","abstract_has_math":false,"creators":["Yalcin, Refik"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-05-22","date_published":"2026-05-22","updated_at":"2026-11-19T10:54:03Z","subjects":["single photon counting","x-ray imaging","analog circuit design"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10012/23384","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10012/23384","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F23384","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Yalcin, Refik"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-05-22T18:08:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-05-22T18:08:26Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-05-22"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2026-05-13"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["single photon counting","x-ray imaging","analog circuit design"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10012/23384"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Spectral X-ray imaging based on single photon counting (SPC) has clear benefits for reducing radiation dose and improving tissue contrast in medical imaging. However, fitting the spectral readout electronics into a small pixel area in order to provide high spatial resolution is still challenging in readout integrated circuit (ROIC) design. This thesis covers the modeling, design, and measurement of a CMOS SPC X-ray imager intended for mammography and computed tomography (CT) that implements, for the first time, frequency-division multiplexed (FDM) readout to achieve high spatial resolution. Reducing pixel dimensions to 50 x 50 µm² is critical to leveraging the \"small-pixel effect\", which is a phenomenon that minimizes the impact of slow charge trapping in some X-ray sensors to drastically improve energy resolution. However, this stringent area constraint renders conventional per-pixel digitization architectures impractical. The proposed architecture, therefore, uses FDM, which allows the analog-to-digital converter (ADC) to be moved outside the pixel so that one ADC can serve an entire column of pixels. This architectural change helps mitigate the area and count-rate limitations inherent in X-ray imagers with in-pixel ADCs. In our proposed ROIC, each pixel contains a charge-sensitive amplifier (CSA) followed by a CR-RC shaper, which then feeds a mixer driven by a local oscillator. The shaped pulses are modulated onto orthogonal carrier frequencies, summed using a transimpedance amplifier (TIA), and then digitized by a shared 8-bit 200 MHz pipelined ADC. Measurements from our ROIC, fabricated in a 1.8-V 180-nm CMOS process, confirm that our proposed multi-carrier FDM readout scheme functions as intended. The ADC achieves a 7.28 bit effective number of bits (ENOB), providing a theoretical maximum of 176 distinct energy bins. In addition the average equivalent noise charge (ENC) is measured to be 96 e- per pixel, and 306 e- per column. Our experimental results demonstrate that FDM is a viable approach for spectral X-ray imaging and point toward a scalable path for future high-resolution SPC imagers."]},{"key":"dc:title","label":"Title","values":["A High-Resolution Frequency-Division-Multiplexed Single-Photon-Counting CMOS X-Ray Imager"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:creator":["Yalcin, Refik"],"dc:date.accessioned":["2026-05-22T18:08:26Z"],"dc:date.available":["2026-05-22T18:08:26Z"],"dc:date.issued":["2026-05-22"],"dc:date.submitted":["2026-05-13"],"dc:description.abstract":["Spectral X-ray imaging based on single photon counting (SPC) has clear benefits for reducing radiation dose and improving tissue contrast in medical imaging. However, fitting the spectral readout electronics into a small pixel area in order to provide high spatial resolution is still challenging in readout integrated circuit (ROIC) design. This thesis covers the modeling, design, and measurement of a CMOS SPC X-ray imager intended for mammography and computed tomography (CT) that implements, for the first time, frequency-division multiplexed (FDM) readout to achieve high spatial resolution. Reducing pixel dimensions to 50 x 50 µm² is critical to leveraging the \"small-pixel effect\", which is a phenomenon that minimizes the impact of slow charge trapping in some X-ray sensors to drastically improve energy resolution. However, this stringent area constraint renders conventional per-pixel digitization architectures impractical. The proposed architecture, therefore, uses FDM, which allows the analog-to-digital converter (ADC) to be moved outside the pixel so that one ADC can serve an entire column of pixels. This architectural change helps mitigate the area and count-rate limitations inherent in X-ray imagers with in-pixel ADCs. In our proposed ROIC, each pixel contains a charge-sensitive amplifier (CSA) followed by a CR-RC shaper, which then feeds a mixer driven by a local oscillator. The shaped pulses are modulated onto orthogonal carrier frequencies, summed using a transimpedance amplifier (TIA), and then digitized by a shared 8-bit 200 MHz pipelined ADC. Measurements from our ROIC, fabricated in a 1.8-V 180-nm CMOS process, confirm that our proposed multi-carrier FDM readout scheme functions as intended. The ADC achieves a 7.28 bit effective number of bits (ENOB), providing a theoretical maximum of 176 distinct energy bins. In addition the average equivalent noise charge (ENC) is measured to be 96 e- per pixel, and 306 e- per column. Our experimental results demonstrate that FDM is a viable approach for spectral X-ray imaging and point toward a scalable path for future high-resolution SPC imagers."],"dc:identifier.uri":["https://hdl.handle.net/10012/23384"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:subject":["single photon counting","x-ray imaging","analog circuit design"],"dc:title":["A High-Resolution Frequency-Division-Multiplexed Single-Photon-Counting CMOS X-Ray Imager"],"dc:type":["Master Thesis"],"others:access_status":["embargo"]},"updated_at":"2026-11-19T10:54:03Z"}