{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/3748"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/3748","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"Hygrothermal Performance of Insulated, Sloped, Wood-Framed Roof Assemblies","abstract":"Roofs are the single enclosure element common to artificial shelters constructed by all cultures in all climate regions. The hygrothermal performance of insulated, sloped, wood-framed roof assemblies has long been of interest to building scientists and building codes alike. Requirements for the ventilation of roof assemblies have been included in building codes for more than 50 years, however moisture problems still occur. Unvented roof assemblies have been suggested as an alternate and potentially superior solution. While unvented roofs have become relatively common in the warmer southern climates of North America, some technical issues remain unclear and the need exists for further study and demonstration of the hygrothermal performance of both ventilated and unvented roof assemblies in cold northern climates. This thesis seeks to address these issues through a review of existing literature, experience and industry practice, field investigation and measurement, analytical calculation and computer simulations.","abstract_html":"Roofs are the single enclosure element common to artificial shelters constructed by all cultures in all climate regions. The hygrothermal performance of insulated, sloped, wood-framed roof assemblies has long been of interest to building scientists and building codes alike. Requirements for the ventilation of roof assemblies have been included in building codes for more than 50 years, however moisture problems still occur. Unvented roof assemblies have been suggested as an alternate and potentially superior solution. While unvented roofs have become relatively common in the warmer southern climates of North America, some technical issues remain unclear and the need exists for further study and demonstration of the hygrothermal performance of both ventilated and unvented roof assemblies in cold northern climates. This thesis seeks to address these issues through a review of existing literature, experience and industry practice, field investigation and measurement, analytical calculation and computer simulations.","abstract_has_math":false,"creators":["Schumacher, Christopher James"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-05-23T14:34:55Z","date_published":"2008-05-23T14:34:55Z","updated_at":"2026-11-19T10:45:58Z","subjects":["roof assemblies","hygrothermal performance","unvented roofs","ventilated attics","sloped roofs","wood-framed roofs"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10012/3748","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10012/3748","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F3748","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Schumacher, Christopher James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-05-23T14:34:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-05-23T14:34:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-05-23T14:34:55Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["roof assemblies","hygrothermal performance","unvented roofs","ventilated attics","sloped roofs","wood-framed roofs"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10012/3748"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Roofs are the single enclosure element common to artificial shelters constructed by all cultures in all climate regions. The hygrothermal performance of insulated, sloped, wood-framed roof assemblies has long been of interest to building scientists and building codes alike. Requirements for the ventilation of roof assemblies have been included in building codes for more than 50 years, however moisture problems still occur. Unvented roof assemblies have been suggested as an alternate and potentially superior solution. While unvented roofs have become relatively common in the warmer southern climates of North America, some technical issues remain unclear and the need exists for further study and demonstration of the hygrothermal performance of both ventilated and unvented roof assemblies in cold northern climates. This thesis seeks to address these issues through a review of existing literature, experience and industry practice, field investigation and measurement, analytical calculation and computer simulations."]},{"key":"dc:title","label":"Title","values":["Hygrothermal Performance of Insulated, Sloped, Wood-Framed Roof Assemblies"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Schumacher, Christopher James"],"dc:date.accessioned":["2008-05-23T14:34:55Z"],"dc:date.available":["2008-05-23T14:34:55Z"],"dc:date.issued":["2008-05-23T14:34:55Z"],"dc:date.submitted":["2008"],"dc:description.abstract":["Roofs are the single enclosure element common to artificial shelters constructed by all cultures in all climate regions. The hygrothermal performance of insulated, sloped, wood-framed roof assemblies has long been of interest to building scientists and building codes alike. Requirements for the ventilation of roof assemblies have been included in building codes for more than 50 years, however moisture problems still occur. Unvented roof assemblies have been suggested as an alternate and potentially superior solution. While unvented roofs have become relatively common in the warmer southern climates of North America, some technical issues remain unclear and the need exists for further study and demonstration of the hygrothermal performance of both ventilated and unvented roof assemblies in cold northern climates. This thesis seeks to address these issues through a review of existing literature, experience and industry practice, field investigation and measurement, analytical calculation and computer simulations."],"dc:identifier.uri":["http://hdl.handle.net/10012/3748"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:subject":["roof assemblies","hygrothermal performance","unvented roofs","ventilated attics","sloped roofs","wood-framed roofs"],"dc:title":["Hygrothermal Performance of Insulated, Sloped, Wood-Framed Roof Assemblies"],"dc:type":["Master Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:45:58Z"}