{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/3976"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/3976","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"Design of Carbon Nanotube Based Field Emission Facility","abstract":"The objective of this research is to build a prototype of a carbon nanotube (CNT)-based micro X-ray tube array, which can be used in a real-time cone-beam computed tomography (CT) scanner for cancer research. The X-ray tube array consists of an electron source, control grids, focusing electrodes, and an anode plate. All the experiments have been executed in an ultra high vacuum environment at a pressure of 10⁻⁷ Torr. A thin film consisting of multi-wall carbon nanotubes (MWNTs) was used as the electron source. A diode configuration was employed to test the field emission performance of the CNT thin film. The current density achieved was 1mA/cm² at 10V/µm. After the initial burn-in process, a relatively steady emission current was obtained for duration of 170 hours. The control grid was made of 25% opening space stainless steels mesh. Meshes with different wire diameters were tested in a triode structure, and some differences were observed. Multi-anode field emission tests and multi-tube electric field simulations were executed. Experiments and simulations have revealed crosstalk between pixels during field emission. Based on the above experiments and simulations, a signal pixel prototype has been fabricated and is being tested. Moreover, some potential optimizations that will be used in the second prototype are also discussed","abstract_html":"The objective of this research is to build a prototype of a carbon nanotube (CNT)-based micro X-ray tube array, which can be used in a real-time cone-beam computed tomography (CT) scanner for cancer research. The X-ray tube array consists of an electron source, control grids, focusing electrodes, and an anode plate. All the experiments have been executed in an ultra high vacuum environment at a pressure of 10⁻⁷ Torr. A thin film consisting of multi-wall carbon nanotubes (MWNTs) was used as the electron source. A diode configuration was employed to test the field emission performance of the CNT thin film. The current density achieved was 1mA/cm² at 10V/µm. After the initial burn-in process, a relatively steady emission current was obtained for duration of 170 hours. The control grid was made of 25% opening space stainless steels mesh. Meshes with different wire diameters were tested in a triode structure, and some differences were observed. Multi-anode field emission tests and multi-tube electric field simulations were executed. Experiments and simulations have revealed crosstalk between pixels during field emission. Based on the above experiments and simulations, a signal pixel prototype has been fabricated and is being tested. Moreover, some potential optimizations that will be used in the second prototype are also discussed","abstract_has_math":false,"creators":["Sun, Yonghai"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-09-12T15:44:22Z","date_published":"2008-09-12T15:44:22Z","updated_at":"2026-11-19T10:54:42Z","subjects":["Carbon Nanotube","Field Emission"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10012/3976","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10012/3976","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F3976","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Sun, Yonghai"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-09-12T15:44:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-09-12T15:44:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-09-12T15:44:22Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2008-08-29"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Carbon Nanotube","Field Emission"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10012/3976"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research is to build a prototype of a carbon nanotube (CNT)-based micro X-ray tube array, which can be used in a real-time cone-beam computed tomography (CT) scanner for cancer research. The X-ray tube array consists of an electron source, control grids, focusing electrodes, and an anode plate. All the experiments have been executed in an ultra high vacuum environment at a pressure of 10⁻⁷ Torr. A thin film consisting of multi-wall carbon nanotubes (MWNTs) was used as the electron source. A diode configuration was employed to test the field emission performance of the CNT thin film. The current density achieved was 1mA/cm² at 10V/µm. After the initial burn-in process, a relatively steady emission current was obtained for duration of 170 hours. The control grid was made of 25% opening space stainless steels mesh. Meshes with different wire diameters were tested in a triode structure, and some differences were observed. Multi-anode field emission tests and multi-tube electric field simulations were executed. Experiments and simulations have revealed crosstalk between pixels during field emission. Based on the above experiments and simulations, a signal pixel prototype has been fabricated and is being tested. Moreover, some potential optimizations that will be used in the second prototype are also discussed"]},{"key":"dc:title","label":"Title","values":["Design of Carbon Nanotube Based Field Emission Facility"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Sun, Yonghai"],"dc:date.accessioned":["2008-09-12T15:44:22Z"],"dc:date.available":["2008-09-12T15:44:22Z"],"dc:date.issued":["2008-09-12T15:44:22Z"],"dc:date.submitted":["2008-08-29"],"dc:description.abstract":["The objective of this research is to build a prototype of a carbon nanotube (CNT)-based micro X-ray tube array, which can be used in a real-time cone-beam computed tomography (CT) scanner for cancer research. The X-ray tube array consists of an electron source, control grids, focusing electrodes, and an anode plate. All the experiments have been executed in an ultra high vacuum environment at a pressure of 10⁻⁷ Torr. A thin film consisting of multi-wall carbon nanotubes (MWNTs) was used as the electron source. A diode configuration was employed to test the field emission performance of the CNT thin film. The current density achieved was 1mA/cm² at 10V/µm. After the initial burn-in process, a relatively steady emission current was obtained for duration of 170 hours. The control grid was made of 25% opening space stainless steels mesh. Meshes with different wire diameters were tested in a triode structure, and some differences were observed. Multi-anode field emission tests and multi-tube electric field simulations were executed. Experiments and simulations have revealed crosstalk between pixels during field emission. Based on the above experiments and simulations, a signal pixel prototype has been fabricated and is being tested. Moreover, some potential optimizations that will be used in the second prototype are also discussed"],"dc:identifier.uri":["http://hdl.handle.net/10012/3976"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:subject":["Carbon Nanotube","Field Emission"],"dc:title":["Design of Carbon Nanotube Based Field Emission Facility"],"dc:type":["Master Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:54:42Z"}