{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/823"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/823","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"An investigation of UV disinfection performance under the influence of turbidity & particulates for drinking water applications","abstract":"UV disinfection performance was investigated under the influence of representative particle sources, including wastewater particles from secondary effluent in a wastewater treatment plant, river particles from surface water, floc particles from coagulated surface water, floc particles from coagulated process water in a drinking water treatment plant, and soil particles from runoff water (planned). Low-pressure (LP) and medium-pressure (MP) UV dose-response of spiked indicator bacteria <i>E. coli</i> was determined using a standard collimated beam apparatus with respect to different particle sources. Significant impacts of wastewater suspended solids (3. 13~4. 8 NTU) agree with the past studies on UV inactivation in secondary effluents. An average difference (statistical significance level of 5% or &alpha;=5%) of the log inactivation was 1. 21 for LP dose and 1. 18 for MP dose. In river water, the presence of surface water particles (12. 0~32. 4 NTU) had no influence on UV inactivation at all LP doses. However, when the floc particles were introduced through coagulation and flocculation, an average difference (&alpha;=5%) of the log inactivation was 1. 25 for LP doses and 1. 12 for MP doses in coagulated river water; an average difference (&alpha;=5%) of the log inactivation was 1. 10 for LP doses in coagulated process water. Chlorination was compared in parallel with UV inactivation in terms of particulate impacts. However, even floc-associated <i>E. coli</i> were too sensitive to carry out the chlorination experiment in the laboratory, indicating that chlorine seems more effective than UV irradiation on inactivation of particle-associated microorganisms. In addition, a comprehensive particle analysis supported the experimental results relevant to this study.","abstract_html":"UV disinfection performance was investigated under the influence of representative particle sources, including wastewater particles from secondary effluent in a wastewater treatment plant, river particles from surface water, floc particles from coagulated surface water, floc particles from coagulated process water in a drinking water treatment plant, and soil particles from runoff water (planned). Low-pressure (LP) and medium-pressure (MP) UV dose-response of spiked indicator bacteria &lt;i&gt;E. coli&lt;/i&gt; was determined using a standard collimated beam apparatus with respect to different particle sources. Significant impacts of wastewater suspended solids (3. 13~4. 8 NTU) agree with the past studies on UV inactivation in secondary effluents. An average difference (statistical significance level of 5% or &amp;alpha;=5%) of the log inactivation was 1. 21 for LP dose and 1. 18 for MP dose. In river water, the presence of surface water particles (12. 0~32. 4 NTU) had no influence on UV inactivation at all LP doses. However, when the floc particles were introduced through coagulation and flocculation, an average difference (&amp;alpha;=5%) of the log inactivation was 1. 25 for LP doses and 1. 12 for MP doses in coagulated river water; an average difference (&amp;alpha;=5%) of the log inactivation was 1. 10 for LP doses in coagulated process water. Chlorination was compared in parallel with UV inactivation in terms of particulate impacts. However, even floc-associated &lt;i&gt;E. coli&lt;/i&gt; were too sensitive to carry out the chlorination experiment in the laboratory, indicating that chlorine seems more effective than UV irradiation on inactivation of particle-associated microorganisms. In addition, a comprehensive particle analysis supported the experimental results relevant to this study.","abstract_has_math":false,"creators":["Liu, Guo"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-19T10:47:52Z","subjects":["Civil & Environmental Engineering"],"languages":["en"],"rights":["Copyright: 2005, Liu, Guo. All rights reserved."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10012/823","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10012/823","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F823","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Liu, Guo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-08-22T13:49:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-08-22T13:49:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil & Environmental Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright: 2005, Liu, Guo. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10012/823"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["UV disinfection performance was investigated under the influence of representative particle sources, including wastewater particles from secondary effluent in a wastewater treatment plant, river particles from surface water, floc particles from coagulated surface water, floc particles from coagulated process water in a drinking water treatment plant, and soil particles from runoff water (planned). Low-pressure (LP) and medium-pressure (MP) UV dose-response of spiked indicator bacteria <i>E. coli</i> was determined using a standard collimated beam apparatus with respect to different particle sources. Significant impacts of wastewater suspended solids (3. 13~4. 8 NTU) agree with the past studies on UV inactivation in secondary effluents. An average difference (statistical significance level of 5% or &alpha;=5%) of the log inactivation was 1. 21 for LP dose and 1. 18 for MP dose. In river water, the presence of surface water particles (12. 0~32. 4 NTU) had no influence on UV inactivation at all LP doses. However, when the floc particles were introduced through coagulation and flocculation, an average difference (&alpha;=5%) of the log inactivation was 1. 25 for LP doses and 1. 12 for MP doses in coagulated river water; an average difference (&alpha;=5%) of the log inactivation was 1. 10 for LP doses in coagulated process water. Chlorination was compared in parallel with UV inactivation in terms of particulate impacts. However, even floc-associated <i>E. coli</i> were too sensitive to carry out the chlorination experiment in the laboratory, indicating that chlorine seems more effective than UV irradiation on inactivation of particle-associated microorganisms. In addition, a comprehensive particle analysis supported the experimental results relevant to this study."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["2260030 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["An investigation of UV disinfection performance under the influence of turbidity & particulates for drinking water applications"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Liu, Guo"],"dc:date.accessioned":["2006-08-22T13:49:11Z"],"dc:date.available":["2006-08-22T13:49:11Z"],"dc:date.issued":["2005"],"dc:date.submitted":["2005"],"dc:description.abstract":["UV disinfection performance was investigated under the influence of representative particle sources, including wastewater particles from secondary effluent in a wastewater treatment plant, river particles from surface water, floc particles from coagulated surface water, floc particles from coagulated process water in a drinking water treatment plant, and soil particles from runoff water (planned). Low-pressure (LP) and medium-pressure (MP) UV dose-response of spiked indicator bacteria <i>E. coli</i> was determined using a standard collimated beam apparatus with respect to different particle sources. Significant impacts of wastewater suspended solids (3. 13~4. 8 NTU) agree with the past studies on UV inactivation in secondary effluents. An average difference (statistical significance level of 5% or &alpha;=5%) of the log inactivation was 1. 21 for LP dose and 1. 18 for MP dose. In river water, the presence of surface water particles (12. 0~32. 4 NTU) had no influence on UV inactivation at all LP doses. However, when the floc particles were introduced through coagulation and flocculation, an average difference (&alpha;=5%) of the log inactivation was 1. 25 for LP doses and 1. 12 for MP doses in coagulated river water; an average difference (&alpha;=5%) of the log inactivation was 1. 10 for LP doses in coagulated process water. Chlorination was compared in parallel with UV inactivation in terms of particulate impacts. However, even floc-associated <i>E. coli</i> were too sensitive to carry out the chlorination experiment in the laboratory, indicating that chlorine seems more effective than UV irradiation on inactivation of particle-associated microorganisms. In addition, a comprehensive particle analysis supported the experimental results relevant to this study."],"dc:format":["application/pdf"],"dc:format.extent":["2260030 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10012/823"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:rights":["Copyright: 2005, Liu, Guo. All rights reserved."],"dc:subject":["Civil & Environmental Engineering"],"dc:title":["An investigation of UV disinfection performance under the influence of turbidity & particulates for drinking water applications"],"dc:type":["Master Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:47:52Z"}