{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/8544"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/8544","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"Energy Efficient RPL Routing Protocol in Smart Buildings","abstract":"Energy is an important factor that must be considered by multi-hop wireless mesh routing protocols because most sensors are powered by batteries with a limited capacity. We focus on the industry-standard RPL (Routing Protocol over Low-power and lossy networks) routing protocol that must find energy-efficient paths in low-power and lossy networks. However, the existing RPL objective functions route based on hop-count and ETX (expected transmission count) metrics alone, ignoring the energy cost of data transmission and reception. We address this issue in two ways. First, we design an objective function for RPL that finds paths that require, in expectation, the minimum amount of energy. Second, we design a probing mechanism which configures the transmission power of sensors to minimize energy consumption. The proposed approach is implemented and evaluated using simulations as well as on a small testbed with two Zolertial Z1 motes.","abstract_html":"Energy is an important factor that must be considered by multi-hop wireless mesh routing protocols because most sensors are powered by batteries with a limited capacity. We focus on the industry-standard RPL (Routing Protocol over Low-power and lossy networks) routing protocol that must find energy-efficient paths in low-power and lossy networks. However, the existing RPL objective functions route based on hop-count and ETX (expected transmission count) metrics alone, ignoring the energy cost of data transmission and reception. We address this issue in two ways. First, we design an objective function for RPL that finds paths that require, in expectation, the minimum amount of energy. Second, we design a probing mechanism which configures the transmission power of sensors to minimize energy consumption. The proposed approach is implemented and evaluated using simulations as well as on a small testbed with two Zolertial Z1 motes.","abstract_has_math":false,"creators":["Rezaei, Elnaz"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-06-20","date_published":"2014-06-20","updated_at":"2026-11-19T10:51:29Z","subjects":["RPL routing protocol","Smart buildings","Energy efficiency"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10012/8544","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10012/8544","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F8544","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Rezaei, Elnaz"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-06-20T15:21:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-06-20T15:21:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-06-20"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["RPL routing protocol","Smart buildings","Energy efficiency"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10012/8544"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Energy is an important factor that must be considered by multi-hop wireless mesh routing protocols because most sensors are powered by batteries with a limited capacity. We focus on the industry-standard RPL (Routing Protocol over Low-power and lossy networks) routing protocol that must find energy-efficient paths in low-power and lossy networks. However, the existing RPL objective functions route based on hop-count and ETX (expected transmission count) metrics alone, ignoring the energy cost of data transmission and reception. We address this issue in two ways. First, we design an objective function for RPL that finds paths that require, in expectation, the minimum amount of energy. Second, we design a probing mechanism which configures the transmission power of sensors to minimize energy consumption. The proposed approach is implemented and evaluated using simulations as well as on a small testbed with two Zolertial Z1 motes."]},{"key":"dc:title","label":"Title","values":["Energy Efficient RPL Routing Protocol in Smart Buildings"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Rezaei, Elnaz"],"dc:date.accessioned":["2014-06-20T15:21:14Z"],"dc:date.available":["2014-06-20T15:21:14Z"],"dc:date.issued":["2014-06-20"],"dc:date.submitted":["2014"],"dc:description.abstract":["Energy is an important factor that must be considered by multi-hop wireless mesh routing protocols because most sensors are powered by batteries with a limited capacity. We focus on the industry-standard RPL (Routing Protocol over Low-power and lossy networks) routing protocol that must find energy-efficient paths in low-power and lossy networks. However, the existing RPL objective functions route based on hop-count and ETX (expected transmission count) metrics alone, ignoring the energy cost of data transmission and reception. We address this issue in two ways. First, we design an objective function for RPL that finds paths that require, in expectation, the minimum amount of energy. Second, we design a probing mechanism which configures the transmission power of sensors to minimize energy consumption. The proposed approach is implemented and evaluated using simulations as well as on a small testbed with two Zolertial Z1 motes."],"dc:identifier.uri":["http://hdl.handle.net/10012/8544"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:subject":["RPL routing protocol","Smart buildings","Energy efficiency"],"dc:title":["Energy Efficient RPL Routing Protocol in Smart Buildings"],"dc:type":["Master Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:51:29Z"}