{"id":{"repo_id":"waterloo","oai_identifier":"oai:uwspace.uwaterloo.ca:10012/921"},"canonical_url":"https://search.ndltd.org/etd/waterloo/oai:uwspace.uwaterloo.ca:10012/921","repository":{"repo_id":"waterloo","name":"University of Waterloo","base_url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request"},"display":{"title":"Phosphor Coated UV-Responsive CCD Image Sensors","abstract":"Typical CCD image sensors are not sensitive to Ultra-Violet (UV) radiation, because the UV photons have a penetration depth of 2nm in the ~1&micro;m thick polysilicon gate material. An inorganic phosphor coating was developed previously (by Wendy Franks et al [1, 2]) that was shown to be a viable solution to creating a UV-sensitive CCD image sensor. The coating absorbs incident UV radiation (250nm) and re-emits it in the visible (550-611nm) where it can penetrate the gate material. This coating was deposited using a settle-coat type deposition. Improved coating techniques are presented here. These include a commercial coating from Applied Scintillation Technologies (AST), a Doctor-Blade coating, e-beam deposition, and laser ablation. The properties of the coating, and of the coated sensors are presented here. Tests performed on the sensors include Quantum Efficiency, Photo-Response Non-Uniformity, Contrast Transfer Function, and Lifetime. The AST coating is a viable method for commercial UV-responsive CCD image sensors. The Doctor-Blade coatings show promise, but issues with clustering of the coating need to be resolved before the sensors can be used commercially. E-beam deposition and laser ablation need further research to provide a viable coating.","abstract_html":"Typical CCD image sensors are not sensitive to Ultra-Violet (UV) radiation, because the UV photons have a penetration depth of 2nm in the ~1&amp;micro;m thick polysilicon gate material. An inorganic phosphor coating was developed previously (by Wendy Franks et al [1, 2]) that was shown to be a viable solution to creating a UV-sensitive CCD image sensor. The coating absorbs incident UV radiation (250nm) and re-emits it in the visible (550-611nm) where it can penetrate the gate material. This coating was deposited using a settle-coat type deposition. Improved coating techniques are presented here. These include a commercial coating from Applied Scintillation Technologies (AST), a Doctor-Blade coating, e-beam deposition, and laser ablation. The properties of the coating, and of the coated sensors are presented here. Tests performed on the sensors include Quantum Efficiency, Photo-Response Non-Uniformity, Contrast Transfer Function, and Lifetime. The AST coating is a viable method for commercial UV-responsive CCD image sensors. The Doctor-Blade coatings show promise, but issues with clustering of the coating need to be resolved before the sensors can be used commercially. E-beam deposition and laser ablation need further research to provide a viable coating.","abstract_has_math":false,"creators":["Alexander, Stefan"],"institution":"University of Waterloo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2002,"date_issued":"2002","date_published":"2002","updated_at":"2026-11-19T10:48:28Z","subjects":["Electrical & Computer Engineering","ultra-violet","ccd","image sensor","phosphor"],"languages":["en"],"rights":["Copyright: 2002, Alexander, Stefan. All rights reserved."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10012/921","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10012/921","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwspace.uwaterloo.ca%3A10012%2F921","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Alexander, Stefan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-08-22T14:00:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-08-22T14:00:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2002"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2002"]},{"key":"dc:publisher","label":"Institution","values":["University of Waterloo"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical & Computer Engineering","ultra-violet","ccd","image sensor","phosphor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright: 2002, Alexander, Stefan. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10012/921"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Typical CCD image sensors are not sensitive to Ultra-Violet (UV) radiation, because the UV photons have a penetration depth of 2nm in the ~1&micro;m thick polysilicon gate material. An inorganic phosphor coating was developed previously (by Wendy Franks et al [1, 2]) that was shown to be a viable solution to creating a UV-sensitive CCD image sensor. The coating absorbs incident UV radiation (250nm) and re-emits it in the visible (550-611nm) where it can penetrate the gate material. This coating was deposited using a settle-coat type deposition. Improved coating techniques are presented here. These include a commercial coating from Applied Scintillation Technologies (AST), a Doctor-Blade coating, e-beam deposition, and laser ablation. The properties of the coating, and of the coated sensors are presented here. Tests performed on the sensors include Quantum Efficiency, Photo-Response Non-Uniformity, Contrast Transfer Function, and Lifetime. The AST coating is a viable method for commercial UV-responsive CCD image sensors. The Doctor-Blade coatings show promise, but issues with clustering of the coating need to be resolved before the sensors can be used commercially. E-beam deposition and laser ablation need further research to provide a viable coating."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["3331909 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Phosphor Coated UV-Responsive CCD Image Sensors"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Alexander, Stefan"],"dc:date.accessioned":["2006-08-22T14:00:22Z"],"dc:date.available":["2006-08-22T14:00:22Z"],"dc:date.issued":["2002"],"dc:date.submitted":["2002"],"dc:description.abstract":["Typical CCD image sensors are not sensitive to Ultra-Violet (UV) radiation, because the UV photons have a penetration depth of 2nm in the ~1&micro;m thick polysilicon gate material. An inorganic phosphor coating was developed previously (by Wendy Franks et al [1, 2]) that was shown to be a viable solution to creating a UV-sensitive CCD image sensor. The coating absorbs incident UV radiation (250nm) and re-emits it in the visible (550-611nm) where it can penetrate the gate material. This coating was deposited using a settle-coat type deposition. Improved coating techniques are presented here. These include a commercial coating from Applied Scintillation Technologies (AST), a Doctor-Blade coating, e-beam deposition, and laser ablation. The properties of the coating, and of the coated sensors are presented here. Tests performed on the sensors include Quantum Efficiency, Photo-Response Non-Uniformity, Contrast Transfer Function, and Lifetime. The AST coating is a viable method for commercial UV-responsive CCD image sensors. The Doctor-Blade coatings show promise, but issues with clustering of the coating need to be resolved before the sensors can be used commercially. E-beam deposition and laser ablation need further research to provide a viable coating."],"dc:format":["application/pdf"],"dc:format.extent":["3331909 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10012/921"],"dc:language.iso":["en"],"dc:publisher":["University of Waterloo"],"dc:rights":["Copyright: 2002, Alexander, Stefan. All rights reserved."],"dc:subject":["Electrical & Computer Engineering","ultra-violet","ccd","image sensor","phosphor"],"dc:title":["Phosphor Coated UV-Responsive CCD Image Sensors"],"dc:type":["Master Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T10:48:28Z"}