{"id":{"repo_id":"wayne-thes","oai_identifier":"oai:digitalcommons.wayne.edu:oa_dissertations-3452"},"canonical_url":"https://search.ndltd.org/etd/wayne-thes/oai:digitalcommons.wayne.edu:oa_dissertations-3452","repository":{"repo_id":"wayne-thes","name":"Wayne State University","base_url":"https://digitalcommons.wayne.edu/do/oai/"},"display":{"title":"Development Of Photoacoustic Tomographic Systems For Brain Hemorrhage Detection","abstract":"Preterm neonates (age) and/or with low birth weight ( Photoacoustic imaging (PAI) is an imaging modality which derives its contrast from differences in optical absorption coefficients of tissue through laser irradiation and acoustic detection. Therefore, PAI derives its signal directly from optical absorbers such as blood; the critical component in a hemorrhage. We discuss operation and processing methods of our Verasonics Vantage system. We then investigate thermal safety of PAI in mouse model for various laser pulse repetitions rates and illumination duration. We then develop two photoacoustic tomographic systems for eventual translation to clinic for hemorrhage detection. One system being a novel TransFontanelle Multispectral Photoacoustic Imaging (TFMPI) probe. The TFMPI probe was developed and tested on, ex-vivo and in-vitro scenarios to demonstrate improved sensitivity over traditional ultrasound. The other being a 3D hemispherical array photoacoustic computed tomography (HA-PACT) system for 3D volumetric imaging of infant brain. The system is designed and tested for feasibility on in-vitro samples.","abstract_html":"Preterm neonates (age) and/or with low birth weight ( Photoacoustic imaging (PAI) is an imaging modality which derives its contrast from differences in optical absorption coefficients of tissue through laser irradiation and acoustic detection. Therefore, PAI derives its signal directly from optical absorbers such as blood; the critical component in a hemorrhage. We discuss operation and processing methods of our Verasonics Vantage system. We then investigate thermal safety of PAI in mouse model for various laser pulse repetitions rates and illumination duration. We then develop two photoacoustic tomographic systems for eventual translation to clinic for hemorrhage detection. One system being a novel TransFontanelle Multispectral Photoacoustic Imaging (TFMPI) probe. The TFMPI probe was developed and tested on, ex-vivo and in-vitro scenarios to demonstrate improved sensitivity over traditional ultrasound. The other being a 3D hemispherical array photoacoustic computed tomography (HA-PACT) system for 3D volumetric imaging of infant brain. The system is designed and tested for feasibility on in-vitro samples.","abstract_has_math":false,"creators":["Kratkiewicz, Karl"],"institution":null,"degree_name":"Ph.D.","degree_level":"Open Access Embargo","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Kamran Avanaki"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:12:58Z","subjects":["brain","Hemorrhage","image reconstruction","linear array","Photoacoustic imaging","ultrasound imaging","Bioimaging and Biomedical Optics","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.wayne.edu/oa_dissertations/2453","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.wayne.edu/oa_dissertations/2453","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.wayne.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.wayne.edu%3Aoa_dissertations-3452","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kamran Avanaki"]},{"key":"dc:creator","label":"Author","values":["Kratkiewicz, Karl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Embargo"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["brain","Hemorrhage","image reconstruction","linear array","Photoacoustic imaging","ultrasound imaging","Bioimaging and Biomedical Optics","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.wayne.edu/oa_dissertations/2453"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Preterm neonates (age) and/or with low birth weight ( Photoacoustic imaging (PAI) is an imaging modality which derives its contrast from differences in optical absorption coefficients of tissue through laser irradiation and acoustic detection. Therefore, PAI derives its signal directly from optical absorbers such as blood; the critical component in a hemorrhage. We discuss operation and processing methods of our Verasonics Vantage system. We then investigate thermal safety of PAI in mouse model for various laser pulse repetitions rates and illumination duration. We then develop two photoacoustic tomographic systems for eventual translation to clinic for hemorrhage detection. One system being a novel TransFontanelle Multispectral Photoacoustic Imaging (TFMPI) probe. The TFMPI probe was developed and tested on, ex-vivo and in-vitro scenarios to demonstrate improved sensitivity over traditional ultrasound. The other being a 3D hemispherical array photoacoustic computed tomography (HA-PACT) system for 3D volumetric imaging of infant brain. The system is designed and tested for feasibility on in-vitro samples."]},{"key":"dc:title","label":"Title","values":["Development Of Photoacoustic Tomographic Systems For Brain Hemorrhage Detection"]}]}],"canonical_facts":{"dc:contributor":["Kamran Avanaki"],"dc:creator":["Kratkiewicz, Karl"],"dc:date.available":["2023-01-01T08:00:00Z"],"dc:date.created":["2020-01-01T08:00:00Z"],"dc:description.abstract":["Preterm neonates (age) and/or with low birth weight ( Photoacoustic imaging (PAI) is an imaging modality which derives its contrast from differences in optical absorption coefficients of tissue through laser irradiation and acoustic detection. Therefore, PAI derives its signal directly from optical absorbers such as blood; the critical component in a hemorrhage. We discuss operation and processing methods of our Verasonics Vantage system. We then investigate thermal safety of PAI in mouse model for various laser pulse repetitions rates and illumination duration. We then develop two photoacoustic tomographic systems for eventual translation to clinic for hemorrhage detection. One system being a novel TransFontanelle Multispectral Photoacoustic Imaging (TFMPI) probe. The TFMPI probe was developed and tested on, ex-vivo and in-vitro scenarios to demonstrate improved sensitivity over traditional ultrasound. The other being a 3D hemispherical array photoacoustic computed tomography (HA-PACT) system for 3D volumetric imaging of infant brain. The system is designed and tested for feasibility on in-vitro samples."],"dc:identifier":["https://digitalcommons.wayne.edu/oa_dissertations/2453"],"dc:subject":["brain","Hemorrhage","image reconstruction","linear array","Photoacoustic imaging","ultrasound imaging","Bioimaging and Biomedical Optics","Biomedical Engineering and Bioengineering"],"dc:title":["Development Of Photoacoustic Tomographic Systems For Brain Hemorrhage Detection"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Open Access Embargo"],"thesis:degree_name":["Ph.D."]},"updated_at":"2026-11-19T09:12:58Z"}