{"id":{"repo_id":"wayne-thes","oai_identifier":"oai:digitalcommons.wayne.edu:oa_dissertations-4529"},"canonical_url":"https://search.ndltd.org/etd/wayne-thes/oai:digitalcommons.wayne.edu:oa_dissertations-4529","repository":{"repo_id":"wayne-thes","name":"Wayne State University","base_url":"https://digitalcommons.wayne.edu/do/oai/"},"display":{"title":"Design And Development Of Bionic 3d Printed Upper-Limb Exoskeleton For Stroke Rehabilitation","abstract":"Abstract DESIGN AND DEVELOPMENT OF BIONIC 3D PRINTED UPPER-LIMB EXOSKELETON FOR STROKE REHABILITATION Those who have had a stroke need long-term physical rehabilitation treatments. The conventional manual hands-on method is time-consuming and cannot offer low-cost, long-term rehabilitation services. Furthermore, the hands-on method is subjective and is dependent on the competence level of physiotherapists. To address these problems, more research and effort are being directed into the development of robotic-assisted rehabilitation technologies. For decades, upper-limb exoskeleton devices have been researched and developed for upper-limb rehabilitation. Some products have been tested on post-stroke patients. However, there are many limits and problems in this field. It currently needs a bionic mechanical design for the upper-limb exoskeleton, focusing mainly on human-machine joint misalignment. Furthermore, upper-limb exoskeleton volitional control is still far from acceptable.In this study, previous attempts to develop an upper-limb exoskeleton were discussed. Important challenges related to mechanical exoskeleton design and control strategy development were undertaken. A new robot control mechanism, known as the mirror or synchronous motion-control method, was developed, as well as tactics for promoting robotic systems in clinical usage. Six healthy individuals participated in an experiment to verify the performance of the motion-controlled upper-limb (UL) exoskeleton. In a 2D panel, the UL exoskeleton executed sketching movements based on the UL movements of a healthy participant. To evaluate the accuracy of the drawing performance, the drawings produced by the UL exoskeleton were compared to drawings done by the participant. To evaluate the inter-rater agreement between the drawings, and thus evaluate UL exoskeleton performance, a reliability statistical study (Cronbach test) was conducted and an image comparison using Python was performed to see the accuracy.","abstract_html":"Abstract DESIGN AND DEVELOPMENT OF BIONIC 3D PRINTED UPPER-LIMB EXOSKELETON FOR STROKE REHABILITATION Those who have had a stroke need long-term physical rehabilitation treatments. The conventional manual hands-on method is time-consuming and cannot offer low-cost, long-term rehabilitation services. Furthermore, the hands-on method is subjective and is dependent on the competence level of physiotherapists. To address these problems, more research and effort are being directed into the development of robotic-assisted rehabilitation technologies. For decades, upper-limb exoskeleton devices have been researched and developed for upper-limb rehabilitation. Some products have been tested on post-stroke patients. However, there are many limits and problems in this field. It currently needs a bionic mechanical design for the upper-limb exoskeleton, focusing mainly on human-machine joint misalignment. Furthermore, upper-limb exoskeleton volitional control is still far from acceptable.In this study, previous attempts to develop an upper-limb exoskeleton were discussed. Important challenges related to mechanical exoskeleton design and control strategy development were undertaken. A new robot control mechanism, known as the mirror or synchronous motion-control method, was developed, as well as tactics for promoting robotic systems in clinical usage. Six healthy individuals participated in an experiment to verify the performance of the motion-controlled upper-limb (UL) exoskeleton. In a 2D panel, the UL exoskeleton executed sketching movements based on the UL movements of a healthy participant. To evaluate the accuracy of the drawing performance, the drawings produced by the UL exoskeleton were compared to drawings done by the participant. To evaluate the inter-rater agreement between the drawings, and thus evaluate UL exoskeleton performance, a reliability statistical study (Cronbach test) was conducted and an image comparison using Python was performed to see the accuracy.","abstract_has_math":false,"creators":["Alshahrani, Yousef Mohammed"],"institution":null,"degree_name":"Ph.D.","degree_level":"WSU Access","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Chaoyang Chen","Mahendra Kavdia"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:14:07Z","subjects":["EXOSKELETON","REHABILITATION","STROKE","UPPER-LIMB","Medicine and Health Sciences"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.wayne.edu/oa_dissertations/3530","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.wayne.edu/oa_dissertations/3530","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.wayne.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.wayne.edu%3Aoa_dissertations-4529","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chaoyang Chen","Mahendra Kavdia"]},{"key":"dc:creator","label":"Author","values":["Alshahrani, Yousef Mohammed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["WSU Access"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["EXOSKELETON","REHABILITATION","STROKE","UPPER-LIMB","Medicine and Health Sciences"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.wayne.edu/oa_dissertations/3530"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Abstract DESIGN AND DEVELOPMENT OF BIONIC 3D PRINTED UPPER-LIMB EXOSKELETON FOR STROKE REHABILITATION Those who have had a stroke need long-term physical rehabilitation treatments. The conventional manual hands-on method is time-consuming and cannot offer low-cost, long-term rehabilitation services. Furthermore, the hands-on method is subjective and is dependent on the competence level of physiotherapists. To address these problems, more research and effort are being directed into the development of robotic-assisted rehabilitation technologies. For decades, upper-limb exoskeleton devices have been researched and developed for upper-limb rehabilitation. Some products have been tested on post-stroke patients. However, there are many limits and problems in this field. It currently needs a bionic mechanical design for the upper-limb exoskeleton, focusing mainly on human-machine joint misalignment. Furthermore, upper-limb exoskeleton volitional control is still far from acceptable.In this study, previous attempts to develop an upper-limb exoskeleton were discussed. Important challenges related to mechanical exoskeleton design and control strategy development were undertaken. A new robot control mechanism, known as the mirror or synchronous motion-control method, was developed, as well as tactics for promoting robotic systems in clinical usage. Six healthy individuals participated in an experiment to verify the performance of the motion-controlled upper-limb (UL) exoskeleton. In a 2D panel, the UL exoskeleton executed sketching movements based on the UL movements of a healthy participant. To evaluate the accuracy of the drawing performance, the drawings produced by the UL exoskeleton were compared to drawings done by the participant. To evaluate the inter-rater agreement between the drawings, and thus evaluate UL exoskeleton performance, a reliability statistical study (Cronbach test) was conducted and an image comparison using Python was performed to see the accuracy."]},{"key":"dc:title","label":"Title","values":["Design And Development Of Bionic 3d Printed Upper-Limb Exoskeleton For Stroke Rehabilitation"]}]}],"canonical_facts":{"dc:contributor":["Chaoyang Chen","Mahendra Kavdia"],"dc:creator":["Alshahrani, Yousef Mohammed"],"dc:date.available":["2021-01-01T08:00:00Z"],"dc:date.created":["2021-01-01T08:00:00Z"],"dc:description.abstract":["Abstract DESIGN AND DEVELOPMENT OF BIONIC 3D PRINTED UPPER-LIMB EXOSKELETON FOR STROKE REHABILITATION Those who have had a stroke need long-term physical rehabilitation treatments. The conventional manual hands-on method is time-consuming and cannot offer low-cost, long-term rehabilitation services. Furthermore, the hands-on method is subjective and is dependent on the competence level of physiotherapists. To address these problems, more research and effort are being directed into the development of robotic-assisted rehabilitation technologies. For decades, upper-limb exoskeleton devices have been researched and developed for upper-limb rehabilitation. Some products have been tested on post-stroke patients. However, there are many limits and problems in this field. It currently needs a bionic mechanical design for the upper-limb exoskeleton, focusing mainly on human-machine joint misalignment. Furthermore, upper-limb exoskeleton volitional control is still far from acceptable.In this study, previous attempts to develop an upper-limb exoskeleton were discussed. Important challenges related to mechanical exoskeleton design and control strategy development were undertaken. A new robot control mechanism, known as the mirror or synchronous motion-control method, was developed, as well as tactics for promoting robotic systems in clinical usage. Six healthy individuals participated in an experiment to verify the performance of the motion-controlled upper-limb (UL) exoskeleton. In a 2D panel, the UL exoskeleton executed sketching movements based on the UL movements of a healthy participant. To evaluate the accuracy of the drawing performance, the drawings produced by the UL exoskeleton were compared to drawings done by the participant. To evaluate the inter-rater agreement between the drawings, and thus evaluate UL exoskeleton performance, a reliability statistical study (Cronbach test) was conducted and an image comparison using Python was performed to see the accuracy."],"dc:identifier":["https://digitalcommons.wayne.edu/oa_dissertations/3530"],"dc:subject":["EXOSKELETON","REHABILITATION","STROKE","UPPER-LIMB","Medicine and Health Sciences"],"dc:title":["Design And Development Of Bionic 3d Printed Upper-Limb Exoskeleton For Stroke Rehabilitation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["WSU Access"],"thesis:degree_name":["Ph.D."]},"updated_at":"2026-11-19T09:14:07Z"}