{"id":{"repo_id":"wayne-thes","oai_identifier":"oai:digitalcommons.wayne.edu:oa_dissertations-4902"},"canonical_url":"https://search.ndltd.org/etd/wayne-thes/oai:digitalcommons.wayne.edu:oa_dissertations-4902","repository":{"repo_id":"wayne-thes","name":"Wayne State University","base_url":"https://digitalcommons.wayne.edu/do/oai/"},"display":{"title":"Motion Sensors And Instrumentation Based On Electrochemical Redox Reaction","abstract":"To detect human body vital physiological signals, an electrochemical wearable sensor and a single-mode artificial mechanoreceptor have been developed and their capabilities to detect cardiorespiratory signals, as well as to detect rapid adaptive and slow adaptive responses have been preliminarily demonstrated. The electrochemical method based on I-/I3- redox couple proves to be a sensitive transduction mechanism. Furthermore, a common gate transimpedance amplifier based on gallium nitride high electron mobility transistor for the mechano-acoustic sensor and the wearable mechanoreceptor was developed. The transistor’s performance at high temperatures has been investigated, and its failure mode at high temperature has been discussed.","abstract_html":"To detect human body vital physiological signals, an electrochemical wearable sensor and a single-mode artificial mechanoreceptor have been developed and their capabilities to detect cardiorespiratory signals, as well as to detect rapid adaptive and slow adaptive responses have been preliminarily demonstrated. The electrochemical method based on I-/I3- redox couple proves to be a sensitive transduction mechanism. Furthermore, a common gate transimpedance amplifier based on gallium nitride high electron mobility transistor for the mechano-acoustic sensor and the wearable mechanoreceptor was developed. The transistor’s performance at high temperatures has been investigated, and its failure mode at high temperature has been discussed.","abstract_has_math":false,"creators":["Feng, Xiaoce"],"institution":null,"degree_name":"Ph.D.","degree_level":"Open Access Embargo","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Yong Xu"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:14:35Z","subjects":["electrochemical redox reaction","GaN HEMT","gel electrolyte","mechanoreceptor","sensor","transimpedance amplifier","Electrical and Computer Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.wayne.edu/oa_dissertations/3903","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.wayne.edu/oa_dissertations/3903","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.wayne.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.wayne.edu%3Aoa_dissertations-4902","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yong Xu"]},{"key":"dc:creator","label":"Author","values":["Feng, Xiaoce"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-04-03T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Embargo"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["electrochemical redox reaction","GaN HEMT","gel electrolyte","mechanoreceptor","sensor","transimpedance amplifier","Electrical and Computer Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.wayne.edu/oa_dissertations/3903"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["To detect human body vital physiological signals, an electrochemical wearable sensor and a single-mode artificial mechanoreceptor have been developed and their capabilities to detect cardiorespiratory signals, as well as to detect rapid adaptive and slow adaptive responses have been preliminarily demonstrated. The electrochemical method based on I-/I3- redox couple proves to be a sensitive transduction mechanism. Furthermore, a common gate transimpedance amplifier based on gallium nitride high electron mobility transistor for the mechano-acoustic sensor and the wearable mechanoreceptor was developed. The transistor’s performance at high temperatures has been investigated, and its failure mode at high temperature has been discussed."]},{"key":"dc:title","label":"Title","values":["Motion Sensors And Instrumentation Based On Electrochemical Redox Reaction"]}]}],"canonical_facts":{"dc:contributor":["Yong Xu"],"dc:creator":["Feng, Xiaoce"],"dc:date.available":["2026-04-03T07:00:00Z"],"dc:date.created":["2023-01-01T08:00:00Z"],"dc:description.abstract":["To detect human body vital physiological signals, an electrochemical wearable sensor and a single-mode artificial mechanoreceptor have been developed and their capabilities to detect cardiorespiratory signals, as well as to detect rapid adaptive and slow adaptive responses have been preliminarily demonstrated. The electrochemical method based on I-/I3- redox couple proves to be a sensitive transduction mechanism. Furthermore, a common gate transimpedance amplifier based on gallium nitride high electron mobility transistor for the mechano-acoustic sensor and the wearable mechanoreceptor was developed. The transistor’s performance at high temperatures has been investigated, and its failure mode at high temperature has been discussed."],"dc:identifier":["https://digitalcommons.wayne.edu/oa_dissertations/3903"],"dc:subject":["electrochemical redox reaction","GaN HEMT","gel electrolyte","mechanoreceptor","sensor","transimpedance amplifier","Electrical and Computer Engineering"],"dc:title":["Motion Sensors And Instrumentation Based On Electrochemical Redox Reaction"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Open Access Embargo"],"thesis:degree_name":["Ph.D."]},"updated_at":"2026-11-19T09:14:35Z"}