{"id":{"repo_id":"wfu","oai_identifier":"oai:wakespace.lib.wfu.edu:10339/112523"},"canonical_url":"https://search.ndltd.org/etd/wfu/oai:wakespace.lib.wfu.edu:10339/112523","repository":{"repo_id":"wfu","name":"Wake Forest University","base_url":"https://wakespace.lib.wfu.edu/oai/request"},"display":{"title":"Understanding & Optimizing Isocenter Placement in Single- and Multi-Isocenter Linear Accelerator-Based Radiosurgery Treatment Planning for Multiple Brain Metastases","abstract":"Linear accelerator-based stereotactic radiosurgery (LSRS) is a common method for treating multiple brain metastases (mBM). The main objective of treatment planning is to adequately dose targets while sparing healthy tissue and critical structures in the brain. Beyond dosimetric plan quality, it is also essential to ensure plans are deliverable, while minimizing treatment time and opportunities for error. An important concept in LSRS is the isocenter, or the point at which the linear accelerator rotates around. Determining the configuration—the number and location—of the treatment isocenter(s) is an important consideration for LSRS treatment of mBM; many methodologies utilize only one isocenter, while others designate one isocenter for each target. This work (1) investigates the impact of isocenter quantity and location on plan quality and (2) creates and validates a case-specific method for isocenter placement optimization that leverages quantitative modeling of anatomical and pathological features. A controlled environment simulating the human head and brain was created and outfitted with configurable tumors and organs. Then, over 3,300 treatment plans were optimized to explore and model the effects of isocenter quantity and location—in tandem with features like target size, depth, and prescription—on plan quality. Separately, in an IRB (Institutional Review Board)-approved clinical study, fifty LSRS plans with one to five isocenters were retrospectively created for 10 mBM cases. For this study, isocenters were designated using k-means clustering, a well-known statistical method. Following the analysis of all previously collected data, an isocenter designation algorithm was designed and iteratively improved upon to account for various phenomena; plans were optimized and compared for each algorithm model. Then, a validation study with five new clinical cases was conducted to compare the simplistic method, final method, and current clinical standard. It was determined that there is a “sweet spot” number of isocenters for every case and that accounting for anatomical and pathological factors can improve the dosimetric return per isocenter. By utilizing the methods described in this body of work, including a novel isocenter placement algorithm, it is possible to create deliverable plans that can successfully treat mBM while improving sparing to healthy brain tissue.","abstract_html":"Linear accelerator-based stereotactic radiosurgery (LSRS) is a common method for treating multiple brain metastases (mBM). The main objective of treatment planning is to adequately dose targets while sparing healthy tissue and critical structures in the brain. Beyond dosimetric plan quality, it is also essential to ensure plans are deliverable, while minimizing treatment time and opportunities for error. An important concept in LSRS is the isocenter, or the point at which the linear accelerator rotates around. Determining the configuration—the number and location—of the treatment isocenter(s) is an important consideration for LSRS treatment of mBM; many methodologies utilize only one isocenter, while others designate one isocenter for each target. This work (1) investigates the impact of isocenter quantity and location on plan quality and (2) creates and validates a case-specific method for isocenter placement optimization that leverages quantitative modeling of anatomical and pathological features. A controlled environment simulating the human head and brain was created and outfitted with configurable tumors and organs. Then, over 3,300 treatment plans were optimized to explore and model the effects of isocenter quantity and location—in tandem with features like target size, depth, and prescription—on plan quality. Separately, in an IRB (Institutional Review Board)-approved clinical study, fifty LSRS plans with one to five isocenters were retrospectively created for 10 mBM cases. For this study, isocenters were designated using k-means clustering, a well-known statistical method. Following the analysis of all previously collected data, an isocenter designation algorithm was designed and iteratively improved upon to account for various phenomena; plans were optimized and compared for each algorithm model. Then, a validation study with five new clinical cases was conducted to compare the simplistic method, final method, and current clinical standard. It was determined that there is a “sweet spot” number of isocenters for every case and that accounting for anatomical and pathological factors can improve the dosimetric return per isocenter. By utilizing the methods described in this body of work, including a novel isocenter placement algorithm, it is possible to create deliverable plans that can successfully treat mBM while improving sparing to healthy brain tissue.","abstract_has_math":false,"creators":["Napolitano, Justin Michael"],"institution":"Wake Forest University","degree_name":null,"degree_level":null,"degree_discipline":"Medical Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-26T03:32:42Z","subjects":["Brain Neoplasms","Multi-Isocenter","Radiosurgery","Radiotherapy Planning Computer-Assisted"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://wakespace.lib.wfu.edu/handle/10339/112523","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://wakespace.lib.wfu.edu/handle/10339/112523","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Awfu%3Aoai%3Awakespace.lib.wfu.edu%3A10339%2F112523","prefix":"oai_dc"},"source_record":{"url":"https://wakespace.lib.wfu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Awakespace.lib.wfu.edu%3A10339%2F112523","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Napolitano, Justin Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-15T08:36:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Wake Forest University"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medical Physics"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Brain Neoplasms","Multi-Isocenter","Radiosurgery","Radiotherapy Planning Computer-Assisted"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://wakespace.lib.wfu.edu/handle/10339/112523"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Linear accelerator-based stereotactic radiosurgery (LSRS) is a common method for treating multiple brain metastases (mBM). The main objective of treatment planning is to adequately dose targets while sparing healthy tissue and critical structures in the brain. Beyond dosimetric plan quality, it is also essential to ensure plans are deliverable, while minimizing treatment time and opportunities for error. An important concept in LSRS is the isocenter, or the point at which the linear accelerator rotates around. Determining the configuration—the number and location—of the treatment isocenter(s) is an important consideration for LSRS treatment of mBM; many methodologies utilize only one isocenter, while others designate one isocenter for each target. This work (1) investigates the impact of isocenter quantity and location on plan quality and (2) creates and validates a case-specific method for isocenter placement optimization that leverages quantitative modeling of anatomical and pathological features. A controlled environment simulating the human head and brain was created and outfitted with configurable tumors and organs. Then, over 3,300 treatment plans were optimized to explore and model the effects of isocenter quantity and location—in tandem with features like target size, depth, and prescription—on plan quality. Separately, in an IRB (Institutional Review Board)-approved clinical study, fifty LSRS plans with one to five isocenters were retrospectively created for 10 mBM cases. For this study, isocenters were designated using k-means clustering, a well-known statistical method. Following the analysis of all previously collected data, an isocenter designation algorithm was designed and iteratively improved upon to account for various phenomena; plans were optimized and compared for each algorithm model. Then, a validation study with five new clinical cases was conducted to compare the simplistic method, final method, and current clinical standard. It was determined that there is a “sweet spot” number of isocenters for every case and that accounting for anatomical and pathological factors can improve the dosimetric return per isocenter. By utilizing the methods described in this body of work, including a novel isocenter placement algorithm, it is possible to create deliverable plans that can successfully treat mBM while improving sparing to healthy brain tissue."]},{"key":"dc:title","label":"Title","values":["Understanding & Optimizing Isocenter Placement in Single- and Multi-Isocenter Linear Accelerator-Based Radiosurgery Treatment Planning for Multiple Brain Metastases"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Napolitano, Justin Michael"],"dc:date.accessioned":["2026-07-15T08:36:42Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Linear accelerator-based stereotactic radiosurgery (LSRS) is a common method for treating multiple brain metastases (mBM). The main objective of treatment planning is to adequately dose targets while sparing healthy tissue and critical structures in the brain. Beyond dosimetric plan quality, it is also essential to ensure plans are deliverable, while minimizing treatment time and opportunities for error. An important concept in LSRS is the isocenter, or the point at which the linear accelerator rotates around. Determining the configuration—the number and location—of the treatment isocenter(s) is an important consideration for LSRS treatment of mBM; many methodologies utilize only one isocenter, while others designate one isocenter for each target. This work (1) investigates the impact of isocenter quantity and location on plan quality and (2) creates and validates a case-specific method for isocenter placement optimization that leverages quantitative modeling of anatomical and pathological features. A controlled environment simulating the human head and brain was created and outfitted with configurable tumors and organs. Then, over 3,300 treatment plans were optimized to explore and model the effects of isocenter quantity and location—in tandem with features like target size, depth, and prescription—on plan quality. Separately, in an IRB (Institutional Review Board)-approved clinical study, fifty LSRS plans with one to five isocenters were retrospectively created for 10 mBM cases. For this study, isocenters were designated using k-means clustering, a well-known statistical method. Following the analysis of all previously collected data, an isocenter designation algorithm was designed and iteratively improved upon to account for various phenomena; plans were optimized and compared for each algorithm model. Then, a validation study with five new clinical cases was conducted to compare the simplistic method, final method, and current clinical standard. It was determined that there is a “sweet spot” number of isocenters for every case and that accounting for anatomical and pathological factors can improve the dosimetric return per isocenter. By utilizing the methods described in this body of work, including a novel isocenter placement algorithm, it is possible to create deliverable plans that can successfully treat mBM while improving sparing to healthy brain tissue."],"dc:identifier.uri":["https://wakespace.lib.wfu.edu/handle/10339/112523"],"dc:language.iso":["en"],"dc:publisher":["Wake Forest University"],"dc:subject":["Brain Neoplasms","Multi-Isocenter","Radiosurgery","Radiotherapy Planning Computer-Assisted"],"dc:title":["Understanding & Optimizing Isocenter Placement in Single- and Multi-Isocenter Linear Accelerator-Based Radiosurgery Treatment Planning for Multiple Brain Metastases"],"dc:type":["Dissertation"],"others:access_status":["open.access"],"thesis:degree_discipline":["Medical Physics"]},"updated_at":"2026-11-26T03:32:42Z"}