{"id":{"repo_id":"wfu","oai_identifier":"oai:wakespace.lib.wfu.edu:10339/37443"},"canonical_url":"https://search.ndltd.org/etd/wfu/oai:wakespace.lib.wfu.edu:10339/37443","repository":{"repo_id":"wfu","name":"Wake Forest University","base_url":"https://wakespace.lib.wfu.edu/oai/request"},"display":{"title":"A Complete Dosimetric Model of the Gamma Knife Perfexion Using Penelope Monte Carlo Codes","abstract":"The Gamma Knife Perfexion is a radiosurgical treatment device used to irradiate targets in the head. It uses 192 high-activity Cobalt-60 sources collimated to a common focus to impart radiological damage to the target structure while minimizing dose to adjacent healthy tissue. Tungsten collimators are organized into eight sectors of 24 sources each; each sector can be set to one of three collimation sizes. The collimators can produce nominal spheres of dose 16 mm, 8 mm, or 4 mm in diameter at the focus. Planning for Gamma Knife stereotactic radiosurgery (GK SRS) is performed using images from computed tomography (CT) and/or magnetic resonance (MR) imaging, as well as manual skull measurements. The manufacturer's software used to plan the delivery of these treatments uses a simplistic set of assumptions that do not consider heterogeneous tissue structures.","abstract_html":"The Gamma Knife Perfexion is a radiosurgical treatment device used to irradiate targets in the head. It uses 192 high-activity Cobalt-60 sources collimated to a common focus to impart radiological damage to the target structure while minimizing dose to adjacent healthy tissue. Tungsten collimators are organized into eight sectors of 24 sources each; each sector can be set to one of three collimation sizes. The collimators can produce nominal spheres of dose 16 mm, 8 mm, or 4 mm in diameter at the focus. Planning for Gamma Knife stereotactic radiosurgery (GK SRS) is performed using images from computed tomography (CT) and/or magnetic resonance (MR) imaging, as well as manual skull measurements. The manufacturer&#x27;s software used to plan the delivery of these treatments uses a simplistic set of assumptions that do not consider heterogeneous tissue structures.","abstract_has_math":false,"creators":["Best, Ryan C. M."],"institution":"Wake Forest University","degree_name":null,"degree_level":null,"degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-26T03:33:09Z","subjects":["dose distribution","independent check","Maximum Allowed Dose Difference","radiosurgery","stereotactic","verification"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://wakespace.lib.wfu.edu/handle/10339/37443","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://wakespace.lib.wfu.edu/handle/10339/37443","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Awfu%3Aoai%3Awakespace.lib.wfu.edu%3A10339%2F37443","prefix":"oai_dc"},"source_record":{"url":"https://wakespace.lib.wfu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Awakespace.lib.wfu.edu%3A10339%2F37443","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Best, Ryan C. M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-09-05T08:35:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-03-05T09:30:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Wake Forest University"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dose distribution","independent check","Maximum Allowed Dose Difference","radiosurgery","stereotactic","verification"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://wakespace.lib.wfu.edu/handle/10339/37443"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Gamma Knife Perfexion is a radiosurgical treatment device used to irradiate targets in the head. It uses 192 high-activity Cobalt-60 sources collimated to a common focus to impart radiological damage to the target structure while minimizing dose to adjacent healthy tissue. Tungsten collimators are organized into eight sectors of 24 sources each; each sector can be set to one of three collimation sizes. The collimators can produce nominal spheres of dose 16 mm, 8 mm, or 4 mm in diameter at the focus. Planning for Gamma Knife stereotactic radiosurgery (GK SRS) is performed using images from computed tomography (CT) and/or magnetic resonance (MR) imaging, as well as manual skull measurements. The manufacturer's software used to plan the delivery of these treatments uses a simplistic set of assumptions that do not consider heterogeneous tissue structures."]},{"key":"dc:title","label":"Title","values":["A Complete Dosimetric Model of the Gamma Knife Perfexion Using Penelope Monte Carlo Codes"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Best, Ryan C. M."],"dc:date.accessioned":["2012-09-05T08:35:21Z"],"dc:date.available":["2013-03-05T09:30:05Z"],"dc:date.issued":["2012"],"dc:description.abstract":["The Gamma Knife Perfexion is a radiosurgical treatment device used to irradiate targets in the head. It uses 192 high-activity Cobalt-60 sources collimated to a common focus to impart radiological damage to the target structure while minimizing dose to adjacent healthy tissue. Tungsten collimators are organized into eight sectors of 24 sources each; each sector can be set to one of three collimation sizes. The collimators can produce nominal spheres of dose 16 mm, 8 mm, or 4 mm in diameter at the focus. Planning for Gamma Knife stereotactic radiosurgery (GK SRS) is performed using images from computed tomography (CT) and/or magnetic resonance (MR) imaging, as well as manual skull measurements. The manufacturer's software used to plan the delivery of these treatments uses a simplistic set of assumptions that do not consider heterogeneous tissue structures."],"dc:identifier.uri":["https://wakespace.lib.wfu.edu/handle/10339/37443"],"dc:language.iso":["en"],"dc:publisher":["Wake Forest University"],"dc:subject":["dose distribution","independent check","Maximum Allowed Dose Difference","radiosurgery","stereotactic","verification"],"dc:title":["A Complete Dosimetric Model of the Gamma Knife Perfexion Using Penelope Monte Carlo Codes"],"dc:type":["Dissertation"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"]},"updated_at":"2026-11-26T03:33:09Z"}