{"id":{"repo_id":"wfu","oai_identifier":"oai:wakespace.lib.wfu.edu:10339/82227"},"canonical_url":"https://search.ndltd.org/etd/wfu/oai:wakespace.lib.wfu.edu:10339/82227","repository":{"repo_id":"wfu","name":"Wake Forest University","base_url":"https://wakespace.lib.wfu.edu/oai/request"},"display":{"title":"Development and Validation of a Brain Phantom for Therapeutic Cooling Devices","abstract":"Tissue cooling has been proven as a viable therapy for multiple conditions and injuries, and has been applied to the brain to treat epilepsy and concussions, leading to improved long-term outcomes. To facilitate the study of temperature reduction as a function of various cooling methods, a thermal brain phantom was developed and analyzed. The phantom is composed of a granular hydrogel through which is circulated 37 degree water, representing blood perfusion. The phantom was tested in a series of cooling trials using a fluid-cooled cooling block during which the perfusion rate was varied. Results were compared against a validated finite difference (FD) model. The model was used to calculate steady state cooling at a depth of 5 mm for all flow rates, for both the phantom experiment and a model of the brain. The FD phantom model showed good agreement with the empirical phantom results. Furthermore, the empirical phantom agreed with the predicted brain response within 3.5% at physiological flow, suggesting a biofidelic thermal response. The phantom will be used as a platform for future studies of thermally-mediated therapies applied to the cerebral cortex.","abstract_html":"Tissue cooling has been proven as a viable therapy for multiple conditions and injuries, and has been applied to the brain to treat epilepsy and concussions, leading to improved long-term outcomes. To facilitate the study of temperature reduction as a function of various cooling methods, a thermal brain phantom was developed and analyzed. The phantom is composed of a granular hydrogel through which is circulated 37 degree water, representing blood perfusion. The phantom was tested in a series of cooling trials using a fluid-cooled cooling block during which the perfusion rate was varied. Results were compared against a validated finite difference (FD) model. The model was used to calculate steady state cooling at a depth of 5 mm for all flow rates, for both the phantom experiment and a model of the brain. The FD phantom model showed good agreement with the empirical phantom results. Furthermore, the empirical phantom agreed with the predicted brain response within 3.5% at physiological flow, suggesting a biofidelic thermal response. The phantom will be used as a platform for future studies of thermally-mediated therapies applied to the cerebral cortex.","abstract_has_math":false,"creators":["Packett, Ryan"],"institution":"Wake Forest University","degree_name":null,"degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-26T03:32:49Z","subjects":["brain","epilepsy","heat transfer"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://wakespace.lib.wfu.edu/handle/10339/82227","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://wakespace.lib.wfu.edu/handle/10339/82227","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Awfu%3Aoai%3Awakespace.lib.wfu.edu%3A10339%2F82227","prefix":"oai_dc"},"source_record":{"url":"https://wakespace.lib.wfu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Awakespace.lib.wfu.edu%3A10339%2F82227","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Packett, Ryan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-06-15T08:36:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-05-15T08:30:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Wake Forest University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["brain","epilepsy","heat transfer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://wakespace.lib.wfu.edu/handle/10339/82227"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Tissue cooling has been proven as a viable therapy for multiple conditions and injuries, and has been applied to the brain to treat epilepsy and concussions, leading to improved long-term outcomes. To facilitate the study of temperature reduction as a function of various cooling methods, a thermal brain phantom was developed and analyzed. The phantom is composed of a granular hydrogel through which is circulated 37 degree water, representing blood perfusion. The phantom was tested in a series of cooling trials using a fluid-cooled cooling block during which the perfusion rate was varied. Results were compared against a validated finite difference (FD) model. The model was used to calculate steady state cooling at a depth of 5 mm for all flow rates, for both the phantom experiment and a model of the brain. The FD phantom model showed good agreement with the empirical phantom results. Furthermore, the empirical phantom agreed with the predicted brain response within 3.5% at physiological flow, suggesting a biofidelic thermal response. The phantom will be used as a platform for future studies of thermally-mediated therapies applied to the cerebral cortex."]},{"key":"dc:title","label":"Title","values":["Development and Validation of a Brain Phantom for Therapeutic Cooling Devices"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Packett, Ryan"],"dc:date.accessioned":["2017-06-15T08:36:07Z"],"dc:date.available":["2022-05-15T08:30:10Z"],"dc:date.issued":["2017"],"dc:description.abstract":["Tissue cooling has been proven as a viable therapy for multiple conditions and injuries, and has been applied to the brain to treat epilepsy and concussions, leading to improved long-term outcomes. To facilitate the study of temperature reduction as a function of various cooling methods, a thermal brain phantom was developed and analyzed. The phantom is composed of a granular hydrogel through which is circulated 37 degree water, representing blood perfusion. The phantom was tested in a series of cooling trials using a fluid-cooled cooling block during which the perfusion rate was varied. Results were compared against a validated finite difference (FD) model. The model was used to calculate steady state cooling at a depth of 5 mm for all flow rates, for both the phantom experiment and a model of the brain. The FD phantom model showed good agreement with the empirical phantom results. Furthermore, the empirical phantom agreed with the predicted brain response within 3.5% at physiological flow, suggesting a biofidelic thermal response. The phantom will be used as a platform for future studies of thermally-mediated therapies applied to the cerebral cortex."],"dc:identifier.uri":["https://wakespace.lib.wfu.edu/handle/10339/82227"],"dc:language.iso":["en"],"dc:publisher":["Wake Forest University"],"dc:subject":["brain","epilepsy","heat transfer"],"dc:title":["Development and Validation of a Brain Phantom for Therapeutic Cooling Devices"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"]},"updated_at":"2026-11-26T03:32:49Z"}