{"id":{"repo_id":"wfu","oai_identifier":"oai:wakespace.lib.wfu.edu:10339/98841"},"canonical_url":"https://search.ndltd.org/etd/wfu/oai:wakespace.lib.wfu.edu:10339/98841","repository":{"repo_id":"wfu","name":"Wake Forest University","base_url":"https://wakespace.lib.wfu.edu/oai/request"},"display":{"title":"IMAGE BASED DOSIMETRY POST TRANSARTERIAL RADIOEMBOLIZATION","abstract":"Transarterial radioembolization (TARE) is an effective form of treatment for unresectable liver malignancies via strategic injection of radioactive Yttrium-90 (90Y) microspheres to the tumor site. A major hindrance to TARE’s effectiveness is the simplicity of current radiation dosimetry models for the treatment. They lack patient specificity, are minimally image based and potentially underestimate the strength of 90Y required to deliver a tumoricidal radiation dose. This likely limits the treatment from obtaining its full clinical impact 32. However, utilizing positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging, it is possible to gain insight into the dose distribution of treatment through a quick, noninvasive emission imaging method 54. In order to have reliable post-TARE dosimetry, PET and SPECT imaging protocols need to first be optimized specifically to capture 90Y distribution. We hypothesize that post-TARE image based dosimetry will be highly dependent on imaging modality parameters; but once optimized, both SPECT and PET based dose distributions will give comparable results.","abstract_html":"Transarterial radioembolization (TARE) is an effective form of treatment for unresectable liver malignancies via strategic injection of radioactive Yttrium-90 (90Y) microspheres to the tumor site. A major hindrance to TARE’s effectiveness is the simplicity of current radiation dosimetry models for the treatment. They lack patient specificity, are minimally image based and potentially underestimate the strength of 90Y required to deliver a tumoricidal radiation dose. This likely limits the treatment from obtaining its full clinical impact 32. However, utilizing positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging, it is possible to gain insight into the dose distribution of treatment through a quick, noninvasive emission imaging method 54. In order to have reliable post-TARE dosimetry, PET and SPECT imaging protocols need to first be optimized specifically to capture 90Y distribution. We hypothesize that post-TARE image based dosimetry will be highly dependent on imaging modality parameters; but once optimized, both SPECT and PET based dose distributions will give comparable results.","abstract_has_math":false,"creators":["Thompson, Briana C"],"institution":"Wake Forest University","degree_name":null,"degree_level":null,"degree_discipline":"Molecular Medicine and Translational Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-26T03:32:52Z","subjects":["image based dosimetry","PET/CT","radiation oncology","SPECT/CT","transarterial radioembolization","Yttrium-90"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://wakespace.lib.wfu.edu/handle/10339/98841","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://wakespace.lib.wfu.edu/handle/10339/98841","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Awfu%3Aoai%3Awakespace.lib.wfu.edu%3A10339%2F98841","prefix":"oai_dc"},"source_record":{"url":"https://wakespace.lib.wfu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Awakespace.lib.wfu.edu%3A10339%2F98841","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Thompson, Briana C"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-06-03T08:36:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-12-02T09:30:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Wake Forest University"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Molecular Medicine and Translational Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["image based dosimetry","PET/CT","radiation oncology","SPECT/CT","transarterial radioembolization","Yttrium-90"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://wakespace.lib.wfu.edu/handle/10339/98841"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Transarterial radioembolization (TARE) is an effective form of treatment for unresectable liver malignancies via strategic injection of radioactive Yttrium-90 (90Y) microspheres to the tumor site. A major hindrance to TARE’s effectiveness is the simplicity of current radiation dosimetry models for the treatment. They lack patient specificity, are minimally image based and potentially underestimate the strength of 90Y required to deliver a tumoricidal radiation dose. This likely limits the treatment from obtaining its full clinical impact 32. However, utilizing positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging, it is possible to gain insight into the dose distribution of treatment through a quick, noninvasive emission imaging method 54. In order to have reliable post-TARE dosimetry, PET and SPECT imaging protocols need to first be optimized specifically to capture 90Y distribution. We hypothesize that post-TARE image based dosimetry will be highly dependent on imaging modality parameters; but once optimized, both SPECT and PET based dose distributions will give comparable results."]},{"key":"dc:title","label":"Title","values":["IMAGE BASED DOSIMETRY POST TRANSARTERIAL RADIOEMBOLIZATION"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Thompson, Briana C"],"dc:date.accessioned":["2021-06-03T08:36:20Z"],"dc:date.available":["2021-12-02T09:30:13Z"],"dc:date.issued":["2021"],"dc:description.abstract":["Transarterial radioembolization (TARE) is an effective form of treatment for unresectable liver malignancies via strategic injection of radioactive Yttrium-90 (90Y) microspheres to the tumor site. A major hindrance to TARE’s effectiveness is the simplicity of current radiation dosimetry models for the treatment. They lack patient specificity, are minimally image based and potentially underestimate the strength of 90Y required to deliver a tumoricidal radiation dose. This likely limits the treatment from obtaining its full clinical impact 32. However, utilizing positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging, it is possible to gain insight into the dose distribution of treatment through a quick, noninvasive emission imaging method 54. In order to have reliable post-TARE dosimetry, PET and SPECT imaging protocols need to first be optimized specifically to capture 90Y distribution. We hypothesize that post-TARE image based dosimetry will be highly dependent on imaging modality parameters; but once optimized, both SPECT and PET based dose distributions will give comparable results."],"dc:identifier.uri":["https://wakespace.lib.wfu.edu/handle/10339/98841"],"dc:language.iso":["en"],"dc:publisher":["Wake Forest University"],"dc:subject":["image based dosimetry","PET/CT","radiation oncology","SPECT/CT","transarterial radioembolization","Yttrium-90"],"dc:title":["IMAGE BASED DOSIMETRY POST TRANSARTERIAL RADIOEMBOLIZATION"],"dc:type":["Dissertation"],"others:access_status":["open.access"],"thesis:degree_discipline":["Molecular Medicine and Translational Science"]},"updated_at":"2026-11-26T03:32:52Z"}